6-44
–
Internal function F48 (Adjusting current with torch switch) is set to "ON" (enabled); or
–
Either of the internal functions F29 to F32 (External input terminal setting) is set to either "4" (Start) or
"5" (Loading welding condition).
6.7.2.34 F52: Data type of data log function
This function enables to select data to save when using the data log function.
The patterns of data which can be saved are as shown in the below table.
For data log function; (
-
Data Backup (Utilization of data)).
6.7.2.35 F53: Sampling speed of data log function
Selects the data sampling interval in using data log function.
The relationship between the setting value and the data sampling is as follows:
For data log function; (
-
Data Backup (Utilization of data)).
6.7.2.36 F54 Tack start process
This function enables to start the wire feeding speed with the normal feeding speed without slow-down
after the welding completion. (which enables the tack welding of less transition time)
• [ON]: Pressing the torch switch within 0.5 seconds after the welding completion can start it with the
normal feeding speed. (The wire feeding speed at this time is not exceeding 5 m/min.)
• [OFF]: disables the function.
6.7.2.37 F55 to F59: Reserved
Used in connection with the automatic machines of other manufacturers.
Setting
Welding current
Welding current
Welding voltage
Welding voltage
Wire feed speed
Wire feed speed
(Command
value)
(Detected value)
(Command
value)
(Detected value)
(Command
value)
(Detected value)
0
-
-
-
-
-
-
1
-
Storable
-
Storable
-
Storable
2
Storable
-
Storable
-
Storable
-
3
Storable
Storable
-
Storable
-
-
4
Storable
Storable
-
-
-
Storable
5
-
Storable
Storable
Storable
-
-
6
-
-
Storable
Storable
-
Storable
7
-
Storable
-
-
Storable
Storable
8
-
-
-
Storable
Storable
Storable
Setting
Sampling interval
1
10 ms
2
100 ms
3
1 s
Содержание OTC Welbee Inverter W400
Страница 2: ......
Страница 8: ...vi MEMO...
Страница 56: ...WIRING OF VOLTAGE DETECTION CABLE AT BASE METAL SIDE CONNECTION CHAPTER 4 4 22...
Страница 116: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 50...
Страница 134: ...CHECKING SOFTWARE VERSION ADMINISTRATOR FUNCTIONS CHAPTER 7 7 18...
Страница 146: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6...
Страница 150: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 10 4 10 2 1 Schematic diagram...
Страница 151: ...10 5 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10...
Страница 158: ...MATERIALS FOR SETTING WELDING CONDITIONS REFERENCE MATERIALS CHAPTER 10 10 12...