6.7.2.32 F50: Current increase and decrease by double-clicking
To increase/decrease the welding current by the torch switch operation, set the current increase/
decrease volume at double-clicking. This function is available when the internal function F48 (Adjusting
current with torch switch) is set to [ON].
•
Set the current increase/decrease volume by double-clicking in the range of -100 to 100 A.
6.7.2.33 F51: Special crater repeat
In the sequence of main welding of the "CRATER-FILL ON (REPEATED)" (during start input holding),
the torch switch operation can switch the welding and crater treatment repeatedly as many time as
needed.
•
[ON]: Setting of "CRATER-FILL ON (REPEATED)" is applied, and transits to the crater treatment by
single-clicking of the torch switch during the welding sequence (start input holding). It is available to
return to the main welding as many times as needed even after transit to the crater treatment by single-
clicking of the torch switch.
When this function is enabled, the LED of "CRATER-FILL ON (REPEATED)" of the CRATER-FILL key
flashes.
•
[OFF]: disables the function.
TIPS
• When this function is set to [ON], automatically the setting of "CRATER-FILL ON
(REPEATED)" is selected, disabling other welding modes. (The CRATER-FILL key does not
work.)
• Single-clicking operation should be within 0.3 seconds.
• At the time of transition to crater, press the torch switch for at least 0.3 seconds.
• Welding method at crater treatment is the same as that of main welding.
Example:
In the setting examples of Initial welding current: 80 A; Main welding current: 100 A; and Crater current:
60 A, the following diagram is available:
•
In the following cases, this function cannot be used:
–
Internal function F11 (Fine adjustment of welding conditions memory) is set to "1" to "30" (enabled);
–
Internal function F44 (Reading welding condition with remote control) is set to "ON" (enabled);
–
Internal function F45 (Special crater sequence) is set to "ON" (enabled);
100 A
80 A
60 A
100 A
60 A
Press 0.3 sec. or more
100 A
60 A
Single (within 0.3 sec.)
ON
OFF
Torch switch
Welding current
Crater-fil
㫃
Main welding
Initial condition
Crater-fil
㫃
Crater-fil
㫃
Main welding
Main welding
Содержание OTC Welbee Inverter W400
Страница 2: ......
Страница 8: ...vi MEMO...
Страница 56: ...WIRING OF VOLTAGE DETECTION CABLE AT BASE METAL SIDE CONNECTION CHAPTER 4 4 22...
Страница 116: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 50...
Страница 134: ...CHECKING SOFTWARE VERSION ADMINISTRATOR FUNCTIONS CHAPTER 7 7 18...
Страница 146: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6...
Страница 150: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 10 4 10 2 1 Schematic diagram...
Страница 151: ...10 5 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10...
Страница 158: ...MATERIALS FOR SETTING WELDING CONDITIONS REFERENCE MATERIALS CHAPTER 10 10 12...