6-5
Chapter 6
W
elding Condition
L
IST
OF
W
ELDING
C
ONDITIONS
W
ELDING
C
ONDITION
C
HAPTER
6
F55
Arc loss detection time
OFF (fixed)
OFF
Used when connecting with OTC automatic
machine.
-
F56
Arc start error
detection time
F57
WCR output ON
delay time
F58
WCR output OFF
delay time
F59
Analog setting switch
F60
Pulse peak current fine
adjustment
-150 to 150
0 (A)
Sets the adjustment value of pulse peak current
in pulse welding.
○
F61
Pulse peak time fine
adjustment
-1.5 to 1.5
0.0 (ms)
Sets the adjustment value of pulse peak time in
pulse welding.
○
F62
Base current fine
adjustment
-60 to 60
0 (A)
Sets the adjustment value of base current in pulse
welding.
○
F63
L pulse peak current fine
adjustment
-150 to 150
0 (A)
Sets the adjustment value of pulse peak current
at the LOW side in pulse welding.
○
F64
L pulse peak time fine
adjustment
-1.5 to 1.5
0.0 (ms)
Sets the adjustment value of pulse peak time at
the LOW side in pulse welding.
○
F65
L-base current fine
adjustment
-60 to 60
0 (A)
Sets the adjustment value of base current at the
LOW side in pulse welding.
○
F66
Feeding amplitude ratio
adjustment
0 to 100
50 (%)
Sets the feeding amplitude ratio of wire feeder
speed in wave pulse welding.
○
F67
Setting change of current
value (initial condition, crater
condition)
OFF/ON
OFF
When “CRATER ON” is selected, sets the current
value of the initial condition and crater condition
in the percentage based on the current value of
the welding condition.
OFF: invalid
ON: settable with percentage
-
F68
Setting of current value
(initial condition)
10 to 300
100 (%)
Sets the current value of the initial condition in the
percentage based on the current value of the
welding condition.
-
F69
Setting of current value
(crater condition)
10 to 300
100 (%)
Sets the current value of the crater condition in
the percentage based on the current value of the
welding condition.
-
F77
Welding power source
identification numbers
1 to 999
1
Sets welding power source identification numbers
of Welding result control function.
-
F78
Prevention of unintended
torch switch operation
OFF/ON
OFF
An error code is displayed when welding is not
performed for five seconds after the pre-flow.
-
F81
Setting to use torch switch in
TIG mode
OFF/ON
OFF
When "DC TIG" welding is selected, ON/OFF of
output is controlled by the torch switch. Crater
sequence, gas control, welding management
functions are also enabled.
OFF: Disabled
ON: Torch switch is enabled.
-
No.
Function Name
Setting range
Initial value
Explanation
Memory
Содержание OTC Welbee Inverter W400
Страница 2: ......
Страница 8: ...vi MEMO...
Страница 56: ...WIRING OF VOLTAGE DETECTION CABLE AT BASE METAL SIDE CONNECTION CHAPTER 4 4 22...
Страница 116: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 50...
Страница 134: ...CHECKING SOFTWARE VERSION ADMINISTRATOR FUNCTIONS CHAPTER 7 7 18...
Страница 146: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6...
Страница 150: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 10 4 10 2 1 Schematic diagram...
Страница 151: ...10 5 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10...
Страница 158: ...MATERIALS FOR SETTING WELDING CONDITIONS REFERENCE MATERIALS CHAPTER 10 10 12...