SETTINGS AND SETTING NUMBERS
: Factory default setting
NOTE)
1. SECOND CODE NO. which are enclosed by bold lines are the factory settings.
2. The settings are applied to the entire group, but if the mode no. inside the parentheses is selected, the settings can be applied to
individual indoor units. However, it is only possible to check any changes made to the settings inside the parentheses in individual
mode. (For group batch operation, the changes are made but the display remains as a factory setting.)
3. Do not set anything not shown on the list. If the applicable functions are not available, they will not be displayed.
4. When returning to normal mode, the remote controller is initialized, so the display might show “88.”
5. When “Filter sign indication setting” or “Nighttime free cooling operation setting” is changed, explain set contents to the customer.
6. See below for details on the settings for cold areas.
– : operate at the set fan strength
In case of Independent operation
– : operate at the set fan strength
Low : operate at the weak fan strength
Defrost operation
Description of
setting
MODE
NO.
FIRST
CODE
NO.
SECOND CODE NO.
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
External ON/OFF
input
12
1
Forced
OFF
ON/OFF
operation
Interval time for
filter sign indication
17
(27)
0
Approx.
2500
hours
Approx.
1250
hours
No
counting
Nighttime free cooling
operation ON/OFF
and starting time
1
OFF
ON
2 hours
later
ON
4 hours
later
ON
6 hours
later
ON
8 hours
later
Initial setting for
ventilation fan
4
Normal
Ultra
High
Normal
Ultra
High
Direct duct
connection with VRV
5
Without
duct
(Setup air
flow rate)
Direct
duct
(Fan
off)
–
Without
duct
(Setup air
flow rate)
–
Direct
duct
(Fan
off)
Without
duct
(Fan
off)
Cold areas (Fan
operation selection for
heating thermo off)
–
–
–
Thermo
OFF: L
Defrost:
OFF
–
Thermo
OFF: L
Defrost:
OFF
Thermo
OFF: –
Defrost:
OFF
Fan for nighttime free
cooling operation
6
High
Ultra
High
Display for ventilation
mode
18
(28)
4
Show
Hide
Supply Fresh-up/
Exhaust Fresh-up
7
Supply Exhaust Supply Exhaust
Low tap setting
19
(29)
1
No
–
–
–
–
–
–
Continuous running
Less
Normal
Fan step for supply
(Air flow rate adjustment)
2
Less
Normal
Greater
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
Fan step for exhaust
(Air flow rate adjustment)
3
Less
Normal
Greater
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
24-hours ventilation
setting
4
No
–
–
–
–
–
–
Continuous running
Less
Normal
Fan residual
operation when
heater connected
8
Disable Disable Enable Enable
Fresh-up ON/OFF
1A
0
OFF
ON
Air conditioner fan
01
02
04
06
08
Heating thermo off
Operation
–
–
Low
Low
–
Defrost
Stop
–
Stop
Stop
Stop
Stop
Oil return
Stop
–
Stop
Stop
Stop
Stop
Air conditioner fan
01
02
04
06
08
Heating thermo off
Operation
–
–
Low
Low
–
Defrost
Stop
–
–
Stop
Stop
Stop
Oil return
Stop
–
–
Stop
Stop
Stop
01_EN_3P130768-6L.fm 14 ページ 2013年3月21日 木曜日 午前11時48分
Содержание VKM100GBMV1
Страница 18: ...white page fm 1...
Страница 19: ...white page fm 2...
Страница 20: ...EM12A038 1303 3P130768 6L DE 00_CV_3P130768 6L fm 2...