50
Sensitivity: System supports 6 levels. The sixth level has the highest sensitivity.
Alarm output: when an alarm occurs, system enables peripheral alarm devices.
Latch: when motion detection complete, system auto delays detecting for a specified time.
The value ranges from 1-300(Unit: second)
Show message: System can pop up a message to alarm you in the local host screen if you
enabled this function.
Alarm upload: System can upload the alarm signal to the network (including alarm center)
if you enabled current function.
Send email: System can send out email to alert you when an alarm occurs.
Record channel: Select the channel to activate recording function once an alarm occurred.
Please make sure you have set MD record in encode interface(Main
Menu->System->Schedule) and schedule record in manual record interface(Main
Menu->Advanced->Manual Record)
Record Delay: System can delay the record for specified time after alarm ended. The value
ranges from 10s to 300s.
Tour: Here you can enable tour function when an alarm occurs. System one-window tour.
Please go to chapter 4.14.2 Display for tour interval setup.
Snapshot: You can enable this function to snapshot image when motion detect alarm occurs.
Buzzer: Highlight the icon to enable this function. The buzzer beeps when an alarm occurs.
Step 3 Click Save button.
4.10.1.2 Video Loss
This function allows you to be informed when video loss phenomenon occurred. You can
enable alarm output channel and then enable show message function.
Step 1 From Main menu->Setting->Event->Video Loss to set video loss item and enable this
function. See Figure 4-45.
Figure 4-45