138
Parameter Function
PTZ: Use COM to control the PTZ.
ITS: Connect to mobile light box or touch screen.
Baud Rate Select the baud rate.
Default setup is 115200.
Data Bit
The value ranges from 5 to 8.
Default setup is 8.
Stop bit
There are two options: 1/2.
Default setup is 1.
Parity
There are five options: none/odd/even/space/mark.
Default setup is none.
5.6.5.7 PTZ
The PTZ interface is shown as in Figure 5-51.
Before setup, please check the following connections are right:
PTZ and decoder connection is right. Decoder address setup is right.
Decoder A (B) line connects with DVR A (B) line.
Click Save button after you complete setup, you can go back to the monitor interface to control
speed dome.
Figure 5-51
Please refer to the following sheet for detailed information.
Parameter
Function
Channel
Select PTZ camera connected channel.
PTZ Type
There are two options: local/remote.
Please select remote type if you are connecting to the network
PTZ.
Protocol
Select the corresponding dome protocol such as PELCOD.