92
Table 4-25
Abandoned object parameters
Parameter
Description
Period
Define a period during which the alarm settings are active.
1.
Click
Setting
, and the period setting interface is displayed.
2.
Configure period.
Method 1: Hold down and drag the left mouse button to select
working period you need.
Method 2: Select
Setting > Event > Video Detection
and click
Setting
on the right side of
Period
.
An interface
is displayed. In this
interface, there are seven
Setting
s altogether each of which
corresponds to a day in a week. Select a
Setting
you want and
there are six periods (period1-period6) below for you to pick up.
3.
Click
Save
of working period.
Duration
The shortest time from placing an object in the detection area to an alarm is
triggered.
Alarm Track
Enable this function and when tripwire is triggered, the Camera will use
thermal lens or visual lens to track the object.
Track Time
Time for the lens to track the object.
To set linked measures such as Audio Linkage and White Light when the rule box detects an
Step 4
object, see "4.4.10 Configure Linked Measures."
Click
Save
.
Step 5
4.4.2.2.4
Missing Object
When an object is taken away from the detection area and the absent time of the object is longer
than the defined one, an alarm will be triggered and linked activities will be executed.
Procedure
Select
Setting > Smart Thermal > IVS
.
Step 1
The
Rule Config
interface is displayed.
Select a preset in
Preset
bar.
Step 2
The camera turns to the position.
Set rules about those missing objects.
Step 3
1)
Click
to add a rule. In the
Rule Type
column list, select
Abandoned Object
. In the
Name
column, double-click a name,
Rule4
, for example, to define it. See Figure 4-47.