User’s Manual
45
Submenu
Setting
AUTO BYPASS
Each individual wired zone can be programmed to be automatically excluded
or not when the area is armed if the wired zone is not ready (for example, an
open window).
●
NO
: Establishes that the wired zone is not automatically excludable (it
blocks the arming of the Area which it belongs to).
●
YES
: Establishes that the wired zone can be automatically bypass
permanently until the Area is disarmed.
●
WITH RESTORE
: Establishes that the wired zone is automatically
excludable but, if it is not ready, it is taken back by the system and can
generate an alarm during the arming in progress.
ALARM
Each individual wired zone can be programmed to react in differentiated
acoustic mode.
●
SIR & BUZZER
: Establishes that the zone generates alarms both on the
buzzers and on the siren outputs.
●
CHIME
: The chime is equivalent to the buzzer and siren option but adds
the
CHIME
parameter to the zone, the
CHIME
parameter makes it
possible to control the zone, with the system disarmed, activating the
keypad buzzer. However, to activate the zone
CHIME
, you need to enable
the zones to be controlled through the
CHIME ZONES
menu of user
menu.
●
SILENT
: Establishes that the wired zone does not generate any type of
sound alarm.
●
BUZZER
: Establishes that the zone generates sound alarms only on
keypad buzzers.
●
SIREN
: Establishes that the zone generates sound alarms only on siren-
type outputs.
ALARM CYCLE
●
In the case of multiple alarms (alarm repetition), you can determine the
behavior of the zones that remain open at the end of the alarm cycle in
progress. For example, a zone has set the value 3 to the
ALARM
REPETITION
parameter, if it remains open at the end of the activated
alarm cycle, you can decide that the alarm is not recycled (alarm cycle is
set to
NO
), or that the alarm is recycled a maximum of 3 times (alarm
cycle is set to
YES
).
●
This function is valid only for
INSTANT
,
DELAY1&2
,
PATH
, and
EXIT END
zones.
ALARM REPEAT
Each individual wired zone can be programmed to generate a limited
number of alarm cycles during the arming phase. The value can be set from
01 through 10 cycles. When a wired zone reaches the programmed number
of alarm cycles, the alarm system is momentarily placed in a state of exclusion
until it is disarmed. After it is disarmed, the alarm cycle count will be reset to
3.
Содержание DHI-ARC3008C
Страница 1: ...Alarm Controller User s Manual ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD V2 0 1...
Страница 25: ...User s Manual 14 2 4 Wiring Figure 2 6 Wiring Figure 2 7 Wiring of detectors...
Страница 31: ...User s Manual 20 4 3 Wiring Figure 4 3 keypad connection...
Страница 41: ...User s Manual 30 5 2 Wiring Figure 5 2 Wiring of detectors...
Страница 45: ...User s Manual 34 Figure 6 2 Remove plugs Step 2 Attach the thermal pad to the 4G module...
Страница 137: ...User s Manual...