User’s Manual
43
TYPE
You can set the zone for the most suitable type for the installation.
●
INSTANT
: The zone reacts to the intrusion immediately without waiting
for any delay period.
●
ENTRY 1 DELAY
: The zone reacts after the delay 1 period is set in the
AREAS
menu.
●
ENTRY 2 DELAY
: The zone reacts after the delay 2 period is set in the
AREAS
menu.
●
Path
: The zone triggers an immediate alarm if it is the first affected by an
intrusion. However, the delay follows for the area to which it belongs. If a
delay 1 zone is the first affected, path indicates that it is a zone will not
trigger an immediate alarm.
●
EXIT END
: The exit end termination zone is used when you want to
terminate an output countdown before it ends. This is very useful when it
is unable to establish an output path with a fixed period, you can set it
very high then terminate. For example, by closing the door on which a
contact is mounted and programmed as an output terminator, the
terminator can also act as a button. After arming successfully, the zone’s
entry delay is
Entry 1 Delay
.
●
24H
: The 24-hour zone is always active regardless of the area to which it
is assigned. This setting is used for anti-opening or high-security
protective measures.
●
WATER LEAK
: The water leak zone is used when you want to install water
leak detector within the alarm system, if you program in the water leak
zone, it will activate the water leak alarm and pre-alarm outputs for the
area to which it belongs.
●
FIRE
: The fire zone is used when you also want to install smoke detector
or buttons within the alarm system, if you program in the fire zone, it will
activate the fire alarm and pre-alarm outputs for the area to which it
belongs. The fire alarm period set in the
SYSTEM TIMING
menu will then
follow and it will never affect intrusion alarms. If it is programmed with
single or double balancing, the tamper will be read and managed as a
FIRE TROUBLE
.
●
PANIC
: The panic zone is active for 24 hours a day and generates a sound
or silent alarm depending on the settings input in the
SYSTEM
FUNCTIONS
menu. Panic outputs are activated for the area to which the
setting is assigned. When a panic zone activates, the display shows
panic
alarm
.
●
ROBBERY
: The zone is active for 24 hours a day and generates a silent
alarm. The hold-up outputs are activated for the area to which the setting
is assigned. The LCD display does not show the alarm and no LED flashes.
●
MEDICAL
: The medical zone is active for 24 hours a day and always
generates a sound alarm by means of a keypad buzzer only. It activates
the help outputs for the area to which the setting is assigned. When it is
in an alarm state, the LCD display shows
MEDICAL ALARM
.
Содержание DHI-ARC3008C
Страница 1: ...Alarm Controller User s Manual ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD V2 0 1...
Страница 25: ...User s Manual 14 2 4 Wiring Figure 2 6 Wiring Figure 2 7 Wiring of detectors...
Страница 31: ...User s Manual 20 4 3 Wiring Figure 4 3 keypad connection...
Страница 41: ...User s Manual 30 5 2 Wiring Figure 5 2 Wiring of detectors...
Страница 45: ...User s Manual 34 Figure 6 2 Remove plugs Step 2 Attach the thermal pad to the 4G module...
Страница 137: ...User s Manual...