5.2.10 Configuring Global Alarm linkages (Optional)
You can configure global alarm linkages across different Access Controllers.
Procedure
Step 1
Select Access Control Config > Global Alarm Linkage.
●
When you have configured both global alarm linkages and local alarm linkages, and if
the global alarm linkages conflict with the local alarm linkages, the last alarm linkages
you have configured will take effective.
●
When you have configured alarm linkages for sub controllers through the main
controller, if the main controller has been restored to the factory defaults, we
recommended you restore the sub controller to factory defaults at the same time.
Step 2
Configure the alarm output.
a. Select an alarm input from the alarm input channel list, and then click Link Alarm
Output.
b. Click Add , select an alarm output channel, and then click OK.
Figure 5-32 Alarm output
c. Turn on the alarm output function and then enter the alarm duration.
d. Click Apply.
Step 3
Configure the door linkage.
a. Select an alarm input from the channel list, and then click Add.
b. Select the linkage door, select the door status, and then click OK.
●
Always Closed: The door automatically locks when an alarm is triggered.
●
Always Open: The door automatically unlocks when an alarm is triggered.
Quick Start Guide