Parameter
Description
Relay open = unlocked: Sets the lock to unlock when the relay
is open.
The electromagnetic lock unlocks in a instant and locks again
immediately when the Access Controller is in the soft reboot.
Step 5
Configure access control parameters.
Step 6
In Unlock Settings , select Or or And from Combination Method.
●
Or: Use one of the selected unlock methods to authorize opening the door.
●
And: Use all of the selected unlock methods to authorize opening the door.
Bluetooth card can not be selected when you set the combination method to And.
Step 7
Select the unlock methods, and then configure the other parameters.
Figure 5-5 Unlock settings
Table 5-2 Unlock settings description
Parameter
Description
Unlock Method (Multi-select)
Supports unlocking through card, fingerprint, password or
Bluetooth card. The Bluetooth card function is turned off by
default.
Bluetooth Mode
The Bluetooth card must be a certain distance away from the
access control device to exchange data and unlock the door.
Following are the ranges that are most suitable for it.
●
Short-range: The Bluetooth unlock range is less than 0.2 m.
●
Mid-range: The Bluetooth unlock range is less than 2 m.
●
Long-range: The Bluetooth unlock range is less than 10 m.
Quick Start Guide