- 29 -
10. OPERATION (continued)
The parameters listed below may be selected with the parameter selection key [3] and adjusted
with the parameter adjusting knob [4]. The set value of the parameter selected appears on the
digital display with the respective unit indicator LED turned ON.
Unit LED
Digital meter
ޣ
Part of Indication
ޤ
㧔
1
㧕
Pre flow time
When the parameter “pre flow time” is selected, the set value appears on the right digital
display with the unit indicator LED for “sec. (sec)” turned ON. In this state, the pre flow time
may be adjusted in the range between 0 and 20 sec. by the use of the parameter adjusting
knob [4].
For lift start mode, however, the parameter “pre flow time” may not be selected.
㧔
2
㧕
Initial current
This parameter may be selected only if the initial current setting is “ON”. When this
parameter is selected, the set value appears on the left digital display with the unit indicator
LED for “ampere (A) ” turned ON. In this state, the initial current may be adjusted in the
range as specified in the table shown on the following page by the use of the parameter
adjusting knob [4].
㧔
3
㧕
Upslope time
This parameter may be selected only if both initial current and slope settings are “ON”.
When this parameter is selected, the set value appears on the right digital display with the
unit indicator LED for “sec. (sec) ” turned ON. In this state, the upslope time may be
adjusted in the range between 0 and 10 sec. by the use of the parameter adjusting knob [4].
㧔
4
㧕
Pulse current
This parameter may be selected only if the pulse setting is “ON”. When this parameter is
selected, the set value appears on the left digital display with the unit indicator LED for
“ampere (A) ” turned ON. In this state, the pulse current may be adjusted in the range as
specified in the table shown on the following page by the use of the parameter adjusting
knob [4].
㧔
5
㧕
Welding current (or Base current)
When this parameter is selected, the set value appears on the left digital display with the
unit indicator LED for “ampere (A) ” turned ON. In this state, the welding current may be
adjusted in the range as specified in the table shown on the following page by the use of the
parameter adjusting knob [4].
If the pulse setting is “ON”, the base current may be set and adjusted in the range same as
that for the welding current.
WARNING
A
Sec
Hz
%
JOB