Appendix 3 Error List
198
Owner’s Manual of BECS- 185 Computerized Control System
Error Number
Error
Solutions
to100 degree. Then adjust “Set
Break Para.”
EC13
Frame over limit
Because the parameters “Set
Frame Soft Protection” has
been set and it is over the set
range at moving the frame,
user can release this parameter
according to the situation.
EC14
Control memory lost
EC16
Step motor err
1. Check whether the frame is
blocked; 2. Make sure the
frame motor is ok. 3. Exam
whether frame driver is
damaged.
EC17
Change clr overtime
1. Check whether the
color-changing motor is
rotating.
2. if it can rotate, please check
the color-changing rheostat,
and the connection between
that rheostat and color
-changing motor
EC18
Half return err
1. Use color-changing wheel to
correct the needle position. 2
、
Check whether the
color-changing rheostat is
damaged or the connection
between the rheostat and the
color-changing motor is off.
EC19
Needle postion err
1. Use color-changing wheel to
correct the needle position. 2
、
Check
whether
the
color-changing rheostat is
damaged or the connection
between the rheostat and the
color-changing motor is off.
EC20
Main motor overtime
1. Check whether the motor
can rotate. 2. If it can rotate,
please check whether the
coupler on the E923A board is
blocked by oil. 3. Check the
Содержание BECS-185