Inspection of pre-lift
a. If the nozzle tester handle is released
with the needle valve engaged in a full lift
condition, the tester pressure drops,
being accompanied by decrease in the
needle valve lift value (indicated value on
the dial gauge).
b.
Take the indicated value on the dial
gauge at the point of time when the sec-
ondary spring completes its operation
and the needle valve puts an end to
descent (the position of needle valve lift
value “ ” as shown in the above and right
figures) and check that the value is with-
in the specified limit.
Measuring point for pre-lift
Take the indicated value on the dial gauge
at a point of primary opening pr
approx. 1 0 kgf•cm
2
.
Note : Locate the point of primary
opening pr approx.
10kgf•cm
2
while dropping the pres-
sure.
- 113 -
200
100
400
500
0
300
kgf / cm
2
EQM4049I
L
0
Tester pressure
Amount of lift
EQM4050I
EQM4051I
L
0
EQM4050I
Primary opening pressure
Tester pressure
Amount of lift
EQM4052I