Disconnect the oven from the power supply.
¡
You can test continuity of safety interlocks and monitor switch by using switch tester or ohmmeter.
¡
The switch operation is checked by the lamp on/off of resistance zero/unlimited.
¡
The sequence of check is interlock monitor switch; primary and secondary interlock switches check.
¡
Make circuits like Fig. a, Fig. b, Fig. c for tests.
40
SAFETY INTERLOCK CONTINUITY TEST
1) In case of interlock monitor check.
(Lamp on or zero resistance)
(ohmmeter)
– Fig. a –
Condition: 1) Door is opened.
2) Common terminal of the monitor
switch disconnected.
3) In case of secondary interlock switch.
(ohmmeter)
– Fig. c –
Condition: 1) Door is closed.
2) In case of primary interlock check.
(Lamp on or zero resistance)
(ohmmeter)
– Fig. b –
Condition: 1) Door is closed.
ƒN
(Schematic diagarm of S/W tester)
Содержание KOR-612L0S
Страница 44: ...Fig 6 Measurement Point 43...
Страница 47: ...46 2 P C B CIRCUIT DIAGRAM L type...
Страница 48: ...47 3 COMPONENT INFORMATION 1 Transistor 2 Diode and Zener Diode...
Страница 49: ...48 4 PRINTED CIRCUITS BOARD...
Страница 53: ...52 EXPLODED VIEW...