38
RELAY “1” OFF TIME
24
18
12
6
0
Check
Result
Cause
Remedy
Customer
education
Check the power
source voltage
with magnetron
Condition
Output
power is low.
Lower than
207 volts
Descrease in
power source
voltage
Normal
Replace
Check the timing
periods of the
RELAY “1” coil
Abnormal
NOTE 3
Defective touch
control circuit
Replace depend-
ing on the result of
output test
Normal
Aging change
of magnetron
NOTE 2:
The following chart shows the timing periods of the RELAY “1”.
NOTE 3:
Interlock monitor switch must be replaced when fuse is blown out.
POWER
Low
M-Low
Med
M-High
High
RELAY “1” ON TIME
5
11
17
23
29