22
WIRING DIAGRAM
Procedure
A) Prepare Microwave Energy Survey Meter, 600cc glass beaker, glass thermometer 100˚C or 212˚F.
B) Pour 275cc
¡
15cc of tap water initially at 20
¡
5˚C(68
¡
9˚F) in the 600cc beaker with an inside diam-
eter of approx. 8.5cm (3.5in).
C) Place it at the center of the tray and set it in a cavity.
D) Close the door and operate the oven.
E) Measure the leakage by using microwave energy survey meter with dual ranges, set to 2,450MHz.
- Measured radiation leakage must not exceed the values prescribed below.
• Leakage for a fully assembled oven with door normally closed must be less than 4mW/cm
2
.
- When measuring the leakage, always use the 5cm
space cone with probe. Hold the probe perpendicu-
lar to the cabinet, door. Place the space cone of the
probe on the door, cabinet, door seam, along the
seam, the door viewing window, the exhaust air
vents, the suction air vents.
- Measuring should be in a counter-clockwise direc-
tion at a rate of 1 inch/sec. If the leakage of the cabi-
net door seam is unknown, move the probe more
slowly.
- When measuring near a corner of the door, keep the probe perpendicular to the areas making sure
the probe end at the base of the cone does not get closer than 2 inches from any metal. If it does,
erroneous reading may result.
Fig. 1
Содержание KOR-612L0S
Страница 44: ...Fig 6 Measurement Point 43...
Страница 47: ...46 2 P C B CIRCUIT DIAGRAM L type...
Страница 48: ...47 3 COMPONENT INFORMATION 1 Transistor 2 Diode and Zener Diode...
Страница 49: ...48 4 PRINTED CIRCUITS BOARD...
Страница 53: ...52 EXPLODED VIEW...