33
OPERATION AND FUCTIONS
Regulation of R-sensor OFF Point
INPUT
Control Object
J18, 22 on Main PCB
Resistance of R-sensor Mid OFF Point
CONTENTS
REMARKS
Regulation of R-sensor OFF point (1.5degree DOWN)
In case refrigeration of refrigerator is weak or insufficient, take the following action.
R-
SENSOR
OP1-
1-2
R26
R70
R71
OP
OP 1-
1-1
R26 : R-SENSOR standard resistance in normal mode (31.4K )
R70 : In case of weak ref., cut J18 to down the standard resistance by 1.5deg(2K)
R71 : In case of weak ref., cut J22 to down the standard resistance by 1.5deg(2K)
R26 = Mid OFF point
R26 + R70 = Mid OFF point - 1.5 deg
R26 + R70 + R71 = Mid OFF point - 3.0 deg
Summary of Function
CONTENTS
REMARKS
How to start function modes
All the modes are started with "LOCK ON" except for "explanation after delivery & installation".
A/S forced defrosting
"FREEZER SET." + "REFRIGERATOR SET." 5
times
Demonstration
"REFRIGERATOR SET." + "SLEEP" 5 times
Explanation after delivery &
installation
"REFRIGERATOR SET." for 3 sec. Right after
first power in
ERROR display
"REFRIGERATOR SET." + "LOCK" 3 times
Содержание FRS-2411
Страница 3: ...2 EXTERNAL VIEWS 1 EXTERNAL SIZE FRS 2431 ...
Страница 4: ...3 EXTERNAL VIEWS FRS 2411 ...
Страница 47: ...46 OPERATION AND FUCTIONS Circuit Diagram of Main PCB ...
Страница 48: ...47 DIAGRAM RSCR TYPE WIRING DIAGRAM ...
Страница 49: ...48 DIAGRAM CSR TYPE ...
Страница 50: ...49 DIAGRAM CIRCUIT WIRING DIAGRAM Main PCB ...
Страница 51: ...50 DIAGRAM Front PCB ...
Страница 78: ...686 AHYEON DONG MAPO GU SEOUL KOREA C P O BOX 8003 SEOUL KOREA DAEWOO ELECTRONICS Corp ...