31
OPERATION AND FUCTIONS
Delay Function of Electric Components
INPUT
Control Object
COMP ON/OFF
COMP
F-FAN
CONTENTS
REMARKS
1) F-fan delay by comp. ON/OFF
F-fan is ON/OFF 1 minute after comp. is ON/OFF.
2) F an Delay and Priority
R F A N
O N c o n d i t io n
0 . 5 s e c .
O N
O N
O N
1 . 0 s e c .
1 . 5 s e c .
F F A N
C F A N
O F F
O F F
O F F
3) F /R-fan delay by door open/close for easy door opening.
Inspection : checkup door opening 2 hours after initial start.
F irst R is ON, 1 second la ter F is ON to protect DC fan against over current at
initial start.
DOOR
R FAN
OP EN
CLOSE
20.5 sec. (0.5sec.
for first 2 hrs.)
21sec. (1sec. for first 2 hrs.)
ON
OF F
ON
OF F
F FAN
1 min.
1 min.
Содержание FRS-2411
Страница 3: ...2 EXTERNAL VIEWS 1 EXTERNAL SIZE FRS 2431 ...
Страница 4: ...3 EXTERNAL VIEWS FRS 2411 ...
Страница 47: ...46 OPERATION AND FUCTIONS Circuit Diagram of Main PCB ...
Страница 48: ...47 DIAGRAM RSCR TYPE WIRING DIAGRAM ...
Страница 49: ...48 DIAGRAM CSR TYPE ...
Страница 50: ...49 DIAGRAM CIRCUIT WIRING DIAGRAM Main PCB ...
Страница 51: ...50 DIAGRAM Front PCB ...
Страница 78: ...686 AHYEON DONG MAPO GU SEOUL KOREA C P O BOX 8003 SEOUL KOREA DAEWOO ELECTRONICS Corp ...