45
OPERATION AND FUCTIONS
Fan Function
How it works ;
ON Condition
OFF Condition
MICOM Port
MICOM Port
Control
Object
Control
Method
31 32 33
IC Collector
31 32 33
IC Collector
Low (10V)
operation
5V 0V 0V
10.35V
0V
Mid (12V)
operation
0V 5V 0V
12.19V
0V
F-FAN
High (14V)
operation
0V 0V 0V
14.38V
5V 5V 5V
0V
ON Condition
OFF Condition
MICOM PORT
MICOM Port
Control
Object
Control
Method
39 40 41
IC Collector
39 40 41
IC Collector
Low
(10V)
operation
0V 5V 5V
10.38V
0V
Mid (12V)
operation
5V 0V 5V
12.24V
0V
R-FAN
High (14V)
operation
5V 5V 5V
14.42V
0V 0V 0V
0V
ON Condition
OFF Condition
MICOM Port
MICOM Port
Control
Object
Control
Method
37 38
IC Collector
37 38
IC Collector
High (14V)
operation
0V 0V
14.54V
0V
C-FAN
Low (10V)
operation
5V 0V
10.45V
5V 5V
0V