background image

43

OPERATION AND FUCTIONS

 Sensors 

 Circuit Diagram 

 

 

 Fnction of Each Sensor 

[ F-sensor ]

 

1) It senses the temperature of freezer compartment and controls Comp., F-fan ON / OFF. 

2) How it works ; 

Working Point 

Low ON 

Mid OFF 

High OFF 

Working Temp. 

-11.0  

-20.0  

26.0  

Resistance 

 

14.74k

 

 

22.33k  

 

30.92k  

Sensing Voltage 

 3.50 V 

 3.00 V 

 2.14 V 

 

[ D-sensor ]

 

  It senses return point of defrosting heater. 

Working Point 

Return point of defrosting heater 

Working Temp. 

10  

Resistance 

 19.53k   

Sensing Voltage 

 3.1 V 

 

[ R-sensor ] 

1) It senses the temperature of refrigerator compartment and controls R-fan ON / OFF. 

2) How it works ; 

Working Point 

Low ON 

Mid OFF 

High OFF 

Working Temp. 

2.65  

0.3  

-1.7  

Resistance 

 

26.88k 

  

29.34k   

32.00k 

 

Sensing Voltage 

 2.90V 

 2.81V 

 2.74V 

 C 

 C 

 C 

 C 

 C 

 C 

 C 

Содержание FRS-2411

Страница 1: ...erformance without notice in the parts list So if you need the latest parts information please refer to PPL Parts Price List in Service Information Center http svc dwe co kr DAEWOO ELECTRONICS Corp Mar 2004 http svc dwe co kr Service Manual Side by Side Refrigerator MODEL FRS 2411 FRS 2431 ...

Страница 2: ... could handle a part in the vicinity of electricity after unplugging 3 You should put on rubber glovers to prevent an electric shock on operation test 4 Make sure the rated current voltage capacity before using an instrument 5 Keep your wet hands away from the metal goods in the freezer compartment not to be frostbitten 6 Be careful not to let water to permeate the electric part in the machine roo...

Страница 3: ...2 EXTERNAL VIEWS 1 EXTERNAL SIZE FRS 2431 ...

Страница 4: ...3 EXTERNAL VIEWS FRS 2411 ...

Страница 5: ...artment 1 Ice cubes storage case 7 Dairy pocket 14 Refrigerator pocket 15 Refrigerator case 5 Freezer pocket 6 Freezer case 11 Chilled case 12 Refrigerator shelve 13 Movable Egg case 2 Freezer light 8 Deordorizer 9 Refrigerator light A 10 Wine holder 3 Water Ice Dispenser 4 Freezer shelve ...

Страница 6: ...oom Pocket 13 Movable Egg case 14 Refrigerator pocket 5 Freezer pocket 11 Chilled case 6 Freezer case 12 Refrigerator shelve 3 Water Ice Dispenser 9 Refrigerator light A 4 Freezer shelve 10 Wine holder 7 Dairy pocket Freezer Refrigerator Compartment 2 Freezer light 8 Deordorizer 1 Ice cubes storage case ...

Страница 7: ...COOLING SYSTEM DEFROST SYSTEM DEFORST CONTROL 425 Automatic Start Stop 190 EXTERNAL DIMENSION mm COOLING CONTROL SYSTEM 656 925 896 1808 Fin Evaporator Forced Fan Cooling System NET WEIGHT kg FRS 2431 CONTENTS MODEL NAME DIVISION FRS 2411 Homebar 127 129 231 USABLE CAPACITY L 2 SPECIFICATIONS ...

Страница 8: ...TARTING CAPACITOR REFRIGERANT R134a VOLTAGE V HZ 100 50 60 110 60 115 120 60 127 60 220 60 220 240 50 230 50 X 3016400100 X 3016400100 X X X RATED VOLTAGE X 200V X 200V X X X RATED CAPACITANCE X 100 X 100 X X X 4 RUNNING CAPACITOR REFRIGERANT R134a VOLTAGE V HZ 100 50 60 110 60 115 120 60 127 60 220 60 220 240 50 230 50 X 400EL15130 X X 3016401170 3016401920 3016401170 RATED VOLTAGE X 230V X X 350...

Страница 9: ...012811110 3012811100 PART CODE TYPE NAME PART CODE SPEC W SPEC W PART CODE 10 LAMP ASSEMBLY REFRIGERANT R134a 100 50 60 110 60 115 120 60 127 60 220 60 220 240 50 230 50 X 120V 15W 240V 15W X 3013600070 3013600060 X 120V 25W 230 240V 25W X 3013602020 3013602010 11 MAIN PCB ASSEMBLY REFRIGERANT R134a VOLTAGE V HZ 100 50 60 110 60 115 120 60 127 60 220 60 220 240 50 230 50 X SBS PREMIUM X 30143C4010...

Страница 10: ...00 3015403000 16 VALVE SOLENOID CRUSHER REFRIGERANT R134a VOLTAGE V HZ 100 50 60 110 60 115 120 60 127 60 220 60 220 240 50 230 50 x 110 127V 60Hz 220 240V 50 60Hz x 3015402900 3015402000 17 VALVE WATER REFRIGERANT R134a VOLTAGE V HZ 100 50 60 110 60 115 120 60 127 60 220 60 220 240 50 230 50 x 110 127V 60Hz 220 240V 50 60Hz x 3015402800 3015402200 SPEC PART CODE SPEC PART CODE SPEC PART CODE SPEC...

Страница 11: ...her country 3 4006D17101 KP 30 For America El Salvador 4 401PD17101 KP 211 For Japan Taiwan 5 3011300801 BP 3PIN 6 3011303010 267 For Chile 7 3011315310 For Israel 8 3011303050 BS 1363A For U K Middle Asia Singapore Malaysia 9 3011301200 KP 551 550 For China Australia Upper power cord s part code is only lead wire without any kinds of terminal or houisng ...

Страница 12: ...000028440 3000028030 3000028450 3000028020 2 ASSEMBLY URETHAN REFRIGERATOR DOOR FRS 2431 Blowing Agent Cyclo Pentane Bright White PCM White Emboss Beige Emboss Inox Looking Ellio 1 Inox Looking Ellio 2 RWB3C GWG1B FBG3B DSG1E ISG3E 3000018830 3000018820 3000018810 3000018840 3000018800 FRS 2411 100V 127V Blowing Agent Cyclo Pentane Bright White PCM White Emboss Beige Emboss Inox Looking Ellio 1 In...

Страница 13: ...cons always ON 5 Water Cube Ice Crushed Ice Initial mode Water 6 Other display modes Normal Operation Silent Mode CUSTOM LCD Normal Mode Load Mode Silence Mode Sleep Mode Freezer Refrigerator BAR DIAL DIAL Temp SEG DIAL DIAL 1 Letters of FRZ REF LOW HIGH SETTEMP FUZZY DEODO SILENT SLEEP Water 2 Icons of FUZZY DEODO SLEEP Water 3 Temp bars and lines ON ON SILENT icon OFF OFF ON ON ON ON ON OFF SPEE...

Страница 14: ...icated at Soft Mid and Mid Strong modes Just temperatures and bars are shown Temperature progress Low Low Mid Mid Mid High HIgh Temp indication 4 3 2 1 0 Number of bars 5EA 3EA 5EA 3EA 5EA 5 SUPER REFRIGERATOR button When this mode is chosen QUICK icon and letters of refrigerator flicker 3 times and ON The set temperature and bars are still the previous value 6 SLEEP button Start by pushing the bu...

Страница 15: ...ater Icon Box is always ON Stop by pushing Lock Ice Maker button again Lock Icer Maker Icon is OFF The Icon Box of Cube Ice Crushed Ice is OFF Water Icon Box is ON 10 Filter information The normal Green LED is on for 6 month after first power input After six month Red LED is on How to reset Filter information Push LOCK button and push the Lock Ice Maker button for 3 seconds ...

Страница 16: ...nt of each mode 3 FC ON OFF DIFF 2 Freezer middle OFF point 20 0 If RT 13 F S OFF point is 2 UP Freezer Middle OFF point 18 4 FC Low Low Mid Mid Mid High DIFF 2 degrees respectively Mid HIgh High DIFF 4 degrees 5 Control point of each mode Temp MODE ON point OFF point Low Mid High STEP DIFF STEP DIFF ON OFF DIFF 1 5 0 2 0 0 2 1 0 2 6 0 1 1 0 1 6 0 2 2 0 1 8 0 1 3 0 2 0 0 Low Mid Mid High Low Low M...

Страница 17: ... REMARKS 1 Temperature modes change by pushing the button 2 R fan are controlled by ON OFF point of each mode 3 RC ON OFF DIFF 0 5 RC middle OFF point 0 7 If RT 13 R S OFF point is 2 UP Refrigerator Middle OFF point 2 7 4 RC Low Low Mid Mid Mid High DIFF 1 degree respectively 5 Prevention of weak poor refrigeration 1 When weak refrigeration is sensed comp is ON regardless of F sensor 2 When R sens...

Страница 18: ...0 7 1 3 Low Mid Mid High 0 3 6 3 5 3 8 3 9 3 7 Super refrigeration proceeds for 40 minutes Example of temperature change Refrigerator Low normal Super refrigeration 1 R fan and comp are ON until R sensor reaches to over refrigeration OFF point 7 2 After reaching to the point it goes on with HIGH mode until the end of Super refrigeration It returns to normal after Quick refrigeration of 40 minutes ...

Страница 19: ... SLEEP on LCD is displayed on 4 Termination of Sleep mode 1 MODE 1 F sensor 9 In case of F sensor error When other button is pushed during this mode Total F R door open time exceeds 30 seconds during the mode If Sleep mode is terminated by and F R fan delay for 5 minutes and restart of this mode is prevented for 40minutes It it exceeds time limit of 130 minute Mode1 is terminated and Mode2 starts ...

Страница 20: ...andard value to decide night below 5 7 Lux optical sensor surface Standard value to decide daytime above 4 16 Lux optical sensor surface 3 Control Method Control Mode F FAN R FAN C FAN Normal 10V 10V 10V Silence Load Control 12V 12V 10V 4 Termination Condition The mode stops if lux value is above the standard for more than 1 minute Control of Each Mode INPUT Control Object 1 CDS SENSOR 2 R SENSOR ...

Страница 21: ... Heater defrosting Pause Defrosting cycle After door opening the load control enters if the condition complies with During Sleep Mode1 load control isn t active 5 Control Method 5 1 Control mode by F R door open time over 30 seconds F R fan works by 14V respectively 5 2 Control mode by F sensor On Point 5 degree F fan works by 14V 5 3 Control mode by R sensor On Point 5 degree R fan works by 14V C...

Страница 22: ... Start stop of load control mode Silence Control Door F S F Fan R S R Fan Door Open 30sec after open Load Mode Start Ref Load Stop Frz Load Stop On 5deg On 5deg Frz Overload Input Frz Load Start Frz Stop Condition after 20min 20min 20min Ref Load 12V 12V 10V 8V 3 Start stop of load control mode Normal defrosting control F S F Fan R S R Fan D efro stin g S ta rt C o n d itio n to s ta rt L o ad M o...

Страница 23: ... Fan 10V 12V C Fan 10V 12V Overload of both compartments Y N Freezer Compartment Overload Refrigerator Compartment Overload Y N Y N F load control over 20 min F sensor OFF point Overload mode control Overload mode Normal mode control N F load control mode stop R sensor OFF point R load control mode stop End Load control is avoided N Y R load control over 20 min Y Y Y N Y N N Y N Control Mode Norma...

Страница 24: ... 35 6 Any error mode R1 F1 D1 F3 RT S Door switch 2 Conditions to start defrosting mode 1 The mode starts in the following conditions Any error happens when total comp work time is 6 or 8 or 10 hours Comp work rate by the 2 hours is over 65 Total door open time is over 3 minutes Any door F or R open time is over 3 minutes Ambient temperature is over 35 2 Defrosting mode starts unconditionally as l...

Страница 25: ... work time is over 10 hours Total time is over 60 hours Comp work time is over 6 hours Any error Comp work rate is over 65 End Defrosting mode starts Yes Yes Yes Yes Yes Yes No No No No No No Comp work time is over 2 hours Total door open time is over 3 minutes Yes Yes No No Comp work time is over 8 hours No No ...

Страница 26: ... of D sensor error 4 Time limit 30 seconds Heater is ON regardless of D sensor temperature right after defrosting start 30 minutes in case of D1 Error 80 minutes in normal control state 1 Time 7 minutes Comp F fan R fan Heater OFF 1 Time 5 minutes Comp ON F R fan Heater OFF Output control and time limit of each defrosting mode PRE COOL Heater Defrosting Pause Fan Delay COMP ON OFF OFF ON F FAN ON ...

Страница 27: ... is displayed on Freezer temperature display part 3 How to stop 1 Push LOCK button 3 times while pushing REF SET button 2 It stops automatically 4 minutes after the start 4 All the error Ccdes are reset if they turn to be normal 5 Error Code ERROR CODE CONTENTS F1 F sensor disconnection short pull down r1 R sensor disconnection short pull down rt RT sensor disconnection short pull down d1 D sensor...

Страница 28: ... sensor is normal the error is terminated automatically 5 Door ERROR dF dR dH on display Cause in case it senses that door is open for more than 1 Control Deletion of function related door switch sensing If door switch open close is sensed the error is terminated automatically After displaying on LCD the mode is terminated 6 C1 ERROR Cause in case comp works for over 3 hours when D sensor temp is ...

Страница 29: ...r temp 5M after Water supply dosen t get high Control Normal control Termination Normal 13 Dispenser S W Error Cause When it senses 1M continuously Control Stop Dispenser Crusher function Display Relative ICON BOX is OFF Termination Normal 14 Malfunction of Ice Drop Motor Cause Malfunction of Ice Drop Motor Check the Motor by pushing Test S W Termination Exchange Motor 15 Eu Error Cause Fully TM p...

Страница 30: ...l or first power input power plugin Defrosting Mode CONTENTS REMARKS If D sensor temp 3 5 defrosting mode starts from Pre cool at first power input Comp is delayed for 6 min at the initial defrosting 6 12 Buzzer or Alarm INPUT Control Object F PCB buttons Door Switch Initial Power Input BUZZER CONTENTS REMARKS 1 Buzzer sounds if any button of F PCB is pushed 2 Buzzer sounds 3 times 3 minutes after...

Страница 31: ...ER SET button REFRIGERATOR SET button Power Cord Electrical components and LCD CONTENTS REMARKS 1 Start Push REFRIGERATOR SET button for 3 seconds within 10 seconds just after power input 2 Control 1 Electrical components are OFF for 3 hours 2 Display operates in normal way Prevention of Compressor Restart INPUT Control Object None Comp CONTENTS REMARKS Comp does not start again for 6 minutes thou...

Страница 32: ...riority R F A N O N c o ndi tio n 0 5s ec O N O N O N 1 0s ec 1 5s ec F FA N C F A N O F F O F F O F F 3 F R fan delay bydoor open close for easy door opening Inspection checkup door opening 2 hours after initial start First R is ON 1 second later F is ON to protect DC fan against over current at initial start DOOR RFAN OPEN CLOSE 20 5sec 0 5sec for first 2hrs 21sec 1sec for first 2hrs ON OFF ON O...

Страница 33: ...F by Home Bar door opening R lights turn ON for 1 minute after sensing HOME BAR switch open If the switch is pushed again within 1 minute the light turns on another 1 minute 4 DISPENSER LAMP CONTROL DISPENSER LAMP turns ON OFF by DISPENSER SW Dispenser Lamp turns ON for 5 seconds after sensing switch close Demonstration Function INPUT Control Object LOCK button REFRIGERATOR SET button SLEEP button...

Страница 34: ... cut J18 to down the standard resistance by 1 5deg 2K R71 In case of weak ref cut J22 to down the standard resistance by 1 5deg 2K R26 Mid OFF point R26 R70 Mid OFF point 1 5 deg R26 R70 R71 Mid OFF point 3 0 deg Summary of Function CONTENTS REMARKS How to start function modes All the modes are started with LOCK ON except for explanation after delivery installation A S forced defrosting FREEZER SE...

Страница 35: ... cut J18 to down the standard resistance by 1 5deg 2K R71 In case of weak ref cut J22 to down the standard resistance by 1 5deg 2K R26 Mid OFF point R26 R70 Mid OFF point 1 5 deg R26 R70 R71 Mid OFF point 3 0 deg Summary of Function CONTENTS REMARKS How to start function modes All the modes are started with LOCK ON except for explanation after delivery installation A S forced defrosting FREEZER SE...

Страница 36: ...tial Power inpu t Ice Make r is horizontal Proceed from Ice maker Mode 3 Water Input hose HTR Control 4 Water Input Ready State 5 Crusher Function Normal operation ON Ice Marker Operation OFF Ice Marker Stop OFF Demo Mode OFF Condition Full Sensing of Ice Operation Processing to Ice Markder Mode during Ice Marker Flow Ice Drop Water Input mode Stop Stop If Normal operation Proceed Auto Stop F DOOR...

Страница 37: ...ns 9 5 below continuously Ice maker comlpete 2 Ice Drop MODE status Ice tray level level normal level 8 11 Max 1 1 8 5 12 2 0 2 10 11 1 1 1 Each Section s Time used in S W ERROR Confirm 2 Ice Drop MOTOR Rotation is Sensible by Each Sections 3 S W ERROR Ice Drop Every Time 4 Ice Drop MOTOR ERROR Stop to the Status START 130 min passed I S 12 5 ICE Drop mode I S 9 5 15 min passed C C C C C Start ICE...

Страница 38: ...able Factor Value Using for A S Steps Water input by Time Maximum Water Inut Time 15 sec 4 RT S 7 13 19 29 39 39 I S 10 9 8 7 6 5 Flow Sensor Normal Operation Flow Pulse Value sets 238 Flow Sensor error Water input time 5 5 sec C C C C C C C C C C C C Water Input Confirm MODE I S Temp Rising Value with RT S Temp Mode after 5 min Estimate of Water Input 1 Sec passed after inlet value on Water input...

Страница 39: ...ater Icon Box is always ON Stop by pushing Lock Ice Maker button again Lock Icer Maker Icon is OFF The Icon Box of Cube Ice Crushed Ice is OFF Water Icon Box is ON 3 Display Initial Mode Wateer ICON Letter is ON A rectangle Line around the icon lights up to indicate your selection is on The Icon of water Ice Cube Crushed Ice is always ON Exception Dispenser S W Error When pushing Lock Ice Maker Lo...

Страница 40: ...sher Motor Crusher Motor D P Lamp D P Lamp D P S V Out D A A C 4 2 Ice Cube D P SW In D P SW In D P S V Flap D P S V Flap Cube S V Cube S V Gear Motor Gear Motor D P Lamp D P Lamp A C A A B D 4 3 Water D P Lamp D P Lamp D P SW In D P SW In Water S V Water S V D A Delay Time A 500ms B 500ms C 2 0s D 5 0s 39 ...

Страница 41: ...40 OPERATION AND FUCTIONS MICOM Circuit Power Circuit DC Output Power Voltage Point Oscilloscope Measurement Remarks DC output 15 7V 11 96V ...

Страница 42: ...e Break Voltage Point Oscilloscope Measurement Remarks SMP SIC PIN 1 2 Voltage between DRAIN and SOURCE below 650V OVP Overvoltage Protection Wave at power input Point Oscilloscope Measurement Remarks SMPS IC PIN 3 4 Minimum standard voltage OVP start 23 2V at ...

Страница 43: ...42 OPERATION AND FUCTIONS Initial Power Wave of Switching Power IC Point Oscilloscope Measurement Remark SMPS IC PIN 3 4 ...

Страница 44: ...74k 22 33k 30 92k Sensing Voltage 3 50 V 3 00 V 2 14 V D sensor It senses return point of defrosting heater Working Point Return point of defrosting heater Working Temp 10 Resistance 19 53k Sensing Voltage 3 1 V R sensor 1 It senses the temperature of refrigerator compartment and controls R fan ON OFF 2 How it works Working Point Low ON Mid OFF High OFF Working Temp 2 65 0 3 1 7 Resistance 26 88k ...

Страница 45: ...PLAY REPLAY REPLAY REPLAY REPLAY REPLAY REPLAY 1 3 7V 10 0 7V 1 0V 10 12V R LAMP 4 3 7V 11 0 7V 4 0V 11 12V DIS LAMP 3 3 7V 12 0 7V 3 0V 12 12V DISP SOL 5 3 7V 13 0 7V 5 0V 13 12V WATER ICE 1 3 7V 10 0 7V 1 0V 10 12V WATER DIS 4 3 7V 11 0 7V 4 0V 11 12V GEAR M 3 3 7V 12 0 7V 3 0V 12 12V D HTR 5 3 7V 13 0 7V 5 0V 13 12V F LAMP 4 3 7V 11 0 7V 4 0V 11 12V CUBE SOL 4 3 7V 11 0 7V 4 0V 11 12V W S HTR 2...

Страница 46: ...0V 0V 0V 14 38V 5V 5V 5V 0V ON Condition OFF Condition MICOM PORT MICOM Port Control Object Control Method 39 40 41 IC Collector 39 40 41 IC Collector Low 10V operation 0V 5V 5V 10 38V 0V Mid 12V operation 5V 0V 5V 12 24V 0V R FAN High 14V operation 5V 5V 5V 14 42V 0V 0V 0V 0V ON Condition OFF Condition MICOM Port MICOM Port Control Object Control Method 37 38 IC Collector 37 38 IC Collector High ...

Страница 47: ...46 OPERATION AND FUCTIONS Circuit Diagram of Main PCB ...

Страница 48: ...47 DIAGRAM RSCR TYPE WIRING DIAGRAM ...

Страница 49: ...48 DIAGRAM CSR TYPE ...

Страница 50: ...49 DIAGRAM CIRCUIT WIRING DIAGRAM Main PCB ...

Страница 51: ...50 DIAGRAM Front PCB ...

Страница 52: ...refrigerator back to the wall for free air ventilation Avoid direct sunlight Once the installation place is ready follow the installation instructions If surround temperature of refrigerator is low below 5 foods can be frozen or the refrigerator can work in abnormal way Check if the refrigerator can pass a doorway or enter a door first Find a suitable place to install Installation Preparation ...

Страница 53: ...5 Becarefulnottodamagethewater linewhenremovingthedoor 2 Turn top hinge fastener counterclockwise 3 4 times Disconnect harness wires 1Unscrew top hinge cover with a screw driver Insert a thin screw driver into the side groove of the cover to remove 3 Lift up the front of hinge to remove After the hinge is removed the door can fall down forward Be careful 4Lift the door straight up to remove 2Unscr...

Страница 54: ...every connection of pipes tubes to ensure there is no water leak 8 The water tube should be connected to the cold water line Check the parts below for installing water supply Some other necessary parts are available at your local service agents Installation Procedure 1 Join Connector A Connector B and Water Valve to the tap water lines The water valve should be connected to the cold water line oth...

Страница 55: ...nerA 2 Checkifthetubeisbentorsqeezed Ifso setitrighttopreventany waterleak FastenerA WaterTube 4 Remove any substances in the filter 1 Open the main tap water valve and check if water comes out of the Water Tube 2 Check if the Water Valve is open in case water does not come out 3 Leave the valve open until clean water is coming out Initial water may contain some substances out of filter manufactur...

Страница 56: ...n front to the top hole of door 4 Turn the hinge fastener tightly to the end Connect harness wirings and screw ground wire 5 Insert the water tube far into the coupling 2Let the top of door close to the cabinet and insert the top hinge pin to the top hole of freezer door Insert the back of hinge to the groove of protrusion first then front to the top hole of door 1Insert the bottom hole of refrige...

Страница 57: ...asten them completely Insert a hexagonal wrench into the groove of adjusting nut and turn clockwise until the door is level 4Once the door is balanced fasten the hinge bolts tightly and screw the front cover 2 Loosen 3 hinge bolts 2 on the left 1 on the right a little Do not unfasten them completely Insert a hexagonal wrench into the groove of adjusting nut and turn clockwise until the door is lev...

Страница 58: ...ND PARTS LIST Total Explded View FRS 2411 CABINET MECH ROOM 17 16 15 14 1 8 3 11 13 2 4 6 7 9 10 12 18 19 20 21 31 23 32 26 27 28 25 22 24 33 34 29 30 56 37 36 43 51 45 46 54 38 39 40 47 50 52 49 48 44 1 55 53 41 42 44 2 ...

Страница 59: ...58 EXPLODED VIEW AND PARTS LIST FRS 2411 R ROOM 66 70 64 65 71 72 59 60 57 58 61 62 82 83 93 94 97 98 92 99 90 91 88 89 68 74 67 69 76 73 79 63 77 80 81 86 96 87 75 95 84 85 ...

Страница 60: ...59 EXPLODED VIEW AND PARTS LIST FRS 2411 F ROOM 119 121 122 120 118 117 110 126 106 115 105 116 104 131 132 129 128 130 109 133 74 134 108 127 107 75 100 101 114 102 103 112 124 123 111 125 113 ...

Страница 61: ... 138 3 135 136 137 151 151 1 149 145 150 140 141 152 153 154 151 2 151 3 151 4 151 6 151 5 155 156 160 159 161 158 157 148 144 170 3 170 1 145 169 168 170 2 163 162 164 141 140 166 165 167 147 143 146 139 170 13 170 12 148 144 170 11 170 9 170 14 170 10 142 170 6 170 170 8 170 7 170 5 170 4 ...

Страница 62: ...ED VIEW AND PARTS LIST FRS 2431 CABINET MECH ROOM 17 16 15 14 1 8 3 11 13 2 4 6 7 9 10 12 18 19 20 21 31 23 32 26 27 28 25 22 24 33 34 29 30 56 37 36 43 51 45 46 54 38 39 40 47 50 52 49 48 44 1 55 53 41 42 44 2 ...

Страница 63: ...62 EXPLODED VIEW AND PARTS LIST FRS 2431 R ROOM 66 70 64 65 71 72 59 60 57 58 61 62 82 83 93 94 97 98 92 99 90 91 88 89 68 74 67 69 76 73 79 63 77 80 81 86 96 87 75 95 84 85 ...

Страница 64: ...63 EXPLODED VIEW AND PARTS LIST FRS 2431 F ROOM 119 121 122 120 118 117 110 126 106 115 105 116 104 131 132 129 128 130 109 133 74 134 108 127 107 75 100 101 114 102 103 112 124 123 111 125 113 ...

Страница 65: ... R DOOR 147 146 143 139 142 138 138 1 138 2 138 3 135 136 137 151 151 1 149 145 150 140 141 152 153 154 151 2 151 3 151 4 151 6 151 5 155 156 160 159 161 158 157 148 144 143 139 147 146 142 145 140 167 164 165 166 163 141 168 2 162 168 168 1 148 144 ...

Страница 66: ... AS 1 19 3012519200 GUIDE CAB W TUBE A AS 1 20 3011485600 COVER GUIDE CAB W TUBE A 1 HIPS 21 3011202000 CLAMP WATER TUBE A 5 PA 66 22 3012917800 HINGE U R AS 1 PO T3 0 23 3012917700 HINGE U L AS 1 PO T3 0 24 3012513300 GUIDE U HINGE U 2 POM 25 7002501611 SCREW MACHINE 2 TRS M5 x 16 MFZN 26 3016001240 SPECIAL BOLT T 8 6 x 22 SWCH22A YL 27 3015306700 SUPPORTER U HI AS 2 PO T5 0 28 3012104400 FOOT AD...

Страница 67: ...FRB 5350NT 47 3014413730 PIPE WICON AS 1 48 3010102100 ABSORBER C MOTR 1 NR FRB 5350NT 49 3012004400 FIXTURE C MOTR 1 SUS 50 3015911500 MOTOR C FAN AS 1 DC12V 2 5W 51 3011802200 FAN 1 ABS O D 3 17 x D110 52 3011200500 CLAMP FAN 1 SUS 304 53 3016806900 DRYER AS 1 XH 9 15g 54 3011474700 COVER MACH ROOM AS 1 SBHG T 0 4 55 7112401211 SCREW TAPPING 6 T1 TRS 4 x 12 MFZN 56 3015403200 VALVE WATER AS 1 57...

Страница 68: ...1 HIPS 81 301 1178200 CASE VEGETB A AS 1 GPPS HIPS 82 3011485400 COVER VEGETB CASE B 1 GPPS 83 301 1178300 CASE VEGETABLE B AS 1 GPPS HIPS 84 3017827500 SHELF WINE AS 1 ABS 85 3016002710 SPECIAL SCREW 2 4 x 12 86 3010903200 CAP SCREW 2 PE 87 3018124000 SWITCH LAMP 1 SP201R 7DR 88 3017100500 FLAP MULT DUCT 1 PP 89 3013345000 INSU MULT DUCT AS 1 F PS 90 3011472700 COVER MULT DUCT 1 HIPS 91 301340810...

Страница 69: ...S 114 3000025900 ASSY ICE MAKER 1 115 1 3012205600 FRAME ICE MAKER 1 HIPS 115 2 3012521300 GUIDE ICING FLOW 1 PP 116 3012013200 FIXTURE C 2 PP 117 3012517900 GUIDE G MOTR BRACKET R 1 ABS 118 BRACKET G MOTR AS 1 119 3012517800 GUIDE G MOTR BRACKET L 1 ABS 120 3011176200 ICE CRUSHER AS 1 121 3012517700 GUIDE ICE CRUSHER R 1 ABS 122 3012520500 GUIDE ICE CRUSHER L 1 ABS 123 3014559510 PLATE LAMP F 1 S...

Страница 70: ...TRS 5 x 16 MFZN 146 7112401211 SCREW TA PPING 8 T1 TRS 4 x 12 MFZN 147 3011472100 COVER HNDL DECO T 1 ABS 148 3011472200 COVER HNDL DECO U 1 ABS 149 3017905500 SOCKET DISP BOX AS 1 250V 1A 150 LAMP DISP 1 151 3011485800 COVER DISPNS BOX AS 1 FR S660CWI 151 1 7173300811 SCREW TAPPTITE 7 T1 PAN 3 x 8 MFZN 151 2 30143C3110 PCB FRONT AS 1 FR S660CW SBS03 HLCD 151 3 3016302600 BUTTON CONTL B 4 ABS 151 ...

Страница 71: ...ET R 2 HIPS 170 3000025300 ASSY R DR 1 FR S580CRI 170 1 3012314500 GASKET R DR AS 1 PVC 170 2 3012314400 GASKET HOMEBAR B AS 1 PVC 170 3 3000003810 ASSY R DR URT 1 170 4 3012314300 GASKET HOMEBAR A AS 1 PVC 170 5 3011471700 COVER FRAME HOMEBAR 1 ABS 170 6 3012918300 HINGE HOMEBAR R AS 1 STS304 170 7 3012918200 HINGE HOMEBAR L AS 1 STS304 170 8 3016030600 SPECIAL SCREW C 8 SUS M5 170 9 10 301095150...

Страница 72: ...N 1 15 PCB MAIN AS 1 16 3011472610 COVER MAIN PCB BOX 1 PP 17 7112401211 SCREW TAPPING 1 T1 TRS 4 x 12 MFZN 18 3013223400 HOSE ICE MAKER TUBE AS 1 19 3012519200 GUIDE CAB W TUBE A AS 1 20 3011485600 COVER GUIDE CAB W TUBE A 1 HIPS 21 3011202000 CLAMP WATER TUBE A 5 PA 66 22 3012917800 HINGE U R AS 1 PO T3 0 23 3012917700 HINGE U L AS 1 PO T3 0 24 3012513300 GUIDE U HINGE U 2 POM 25 7002501611 SCRE...

Страница 73: ...DRAIN B 1 PE FRB 5350NT 47 3014413730 PIPE WICON AS 1 48 3010102100 ABSORBER C MOTR 1 NR FRB 5350NT 49 3012004400 FIXTURE C MOTR 1 SUS 50 3015911500 MOTOR C FAN AS 1 DC12V 2 5W 51 3011802200 FAN 1 ABS O D 3 17 x D110 52 3011200500 CLAMP FAN 1 SUS 304 53 3016806900 DRYER AS 1 XH 9 15g 54 3011474700 COVER MACH ROOM AS 1 SBHG T0 4 55 7112401211 SCREW TAPPING 6 T1 TRS 4 x 12 MFZN 56 3015403200 VALVE W...

Страница 74: ...PS 81 301 1178200 CASE VEGETB A AS 1 GPPS HIPS 82 3011485400 COVER VEGETB CASE B 1 GPPS 83 301 1178300 CASE VEGETABLE B AS 1 GPPS HIPS 84 3017827500 SHELF WINE AS 1 ABS 85 3016002710 SPECIAL SCREW 2 4 x 12 86 3010903200 CAP SCREW 2 PE 87 3018124000 SWITCH LAMP 1 SP201R 7DR 88 3017100500 FLAP MULT DUCT 1 PP 89 3013345000 INSU MULT DUCT AS 1 F PS 90 3011472700 COVER MULT DUCT 1 HIPS 91 3013408100 KN...

Страница 75: ...BS 114 3000025900 ASSY ICE MAKER 1 115 1 3012205600 FRAME ICE MAKER 1 HIPS 115 2 3012521300 GUIDE ICING FLOW 1 PP 116 3012013200 FIXTURE C 2 PP 117 3012517900 GUIDE G MOTR BRACKET R 1 ABS 118 BRACKET G MOTR AS 1 119 3012517800 GUIDE G MOTR BRACKET L 1 ABS 120 3011176200 ICE CRUSHER AS 1 121 3012517700 GUIDE ICE CRUSHER R 1 ABS 122 3012520500 GUIDE ICE CRUSHER L 1 ABS 123 3014559510 PLATE LAMP F 1 ...

Страница 76: ... X 16 MFZN 146 7112401211 SCREW TAPPING 6 T1 TRS 4 x 12 MFZN 147 3011472100 COVER HNDL DECO T 1 ABS 148 3011472200 COVER HNDL DECO U 1 ABS 149 3017905500 SOCKET DISP BOX AS 1 250V 1A 150 LAMP DISP 1 151 3011485800 COVER DISPNS BOX AS 1 FR S650CWI 151 1 7173300811 SCREW TA PPTITE 7 T1 PAN 3 x 8 MFZN 151 2 30143C3110 PCB FRONT AS 1 FR S660CW SBS03 HLCD 151 3 3016302600 BUTTON CONTL B 4 ABS 151 4 301...

Страница 77: ...161 3012402100 GRILLE DISPENSER 1 ABS 162 3019019400 POCKET DAIRY AS 1 GPPS HIPS 163 3019019300 POCKET R S 1 GPPS 164 3019019800 POCKET R M 2 HIPS 165 3012514100 GUIDE R POKT 2 HIPS 166 3012513400 GUIDE BOTL 2 PP 167 3019019200 POCKET R 2 HIPS 168 3000018800 ASSY R DR 1 FR S580CG 168 1 3012314500 GASKET R DR AS 1 PVC 168 2 3000003810 ASSY R DR URT 1 ...

Страница 78: ...686 AHYEON DONG MAPO GU SEOUL KOREA C P O BOX 8003 SEOUL KOREA DAEWOO ELECTRONICS Corp ...