16
OPERATION AND FUCTIONS
CONTENTS
REMARKS
6. SUPER FREEZER. (Quick Freezing)
1) Comp. and F-fan are ON (about 150 minutes) regardless of F-sensor.
2) F-fan runs at 14V for the first 90 min., then at 12V for the rest time.
F/S
F Fan
SUPER FRZ. start
F-fan RPM
change point
Normal operation
90min.
14V
12V
60min.
* ON/OFF DIFF. :
fixed by MICOM
* STEP DIFF. :
fixed by MICOM
* Comp. and C-fan :
linked
Te mperature Control of Refrigerator Compartment (RC)
INPUT
Control Object
1. REFRIGERATOR SET. button
2. R-sensor
1. COMP
2. R-FAN
CONTENTS
REMARKS
1. Temperature modes change by pushing the button.
2. R-fan are controlled by ON / OFF point of each mode.
3. RC [ON / OFF] DIFF : 0.5
( RC middle OFF point : 0.7
)
( If RT
≤
13
, R-S OFF point is 2
UP. Refrigerator Middle OFF
point : 2.7
)
4. RC [Low
(Low-Mid)
Mid
(Mid-High)] DIFF : 1 degree respectively
5. Prevention of weak/poor-refrigeration
1) When weak refrigeration is sensed, comp. is ON regardless of F-sensor.
2) When R-sensor reaches R-fan OFF point, comp. is controlled by F-sensor and
R-fan turns OFF.
3) Sensing point of weak refrigeration : R-sensor OFF point of each mode + 7
4) Termination point : Same as R-sensor OFF point of each mode
* ON/OFF Diff. :
fixed by MICOM
* STEP DIFF. :
fixed by MICOM
Low Low-Mid
Mid
Mid-High High
C
C
C
C
C
C
Содержание FRS-2411
Страница 3: ...2 EXTERNAL VIEWS 1 EXTERNAL SIZE FRS 2431 ...
Страница 4: ...3 EXTERNAL VIEWS FRS 2411 ...
Страница 47: ...46 OPERATION AND FUCTIONS Circuit Diagram of Main PCB ...
Страница 48: ...47 DIAGRAM RSCR TYPE WIRING DIAGRAM ...
Страница 49: ...48 DIAGRAM CSR TYPE ...
Страница 50: ...49 DIAGRAM CIRCUIT WIRING DIAGRAM Main PCB ...
Страница 51: ...50 DIAGRAM Front PCB ...
Страница 78: ...686 AHYEON DONG MAPO GU SEOUL KOREA C P O BOX 8003 SEOUL KOREA DAEWOO ELECTRONICS Corp ...