1. Freezer Defrost Process
- Time limit : 50 minutes. ( Comp., Freezer Fan, Step Valve is active. ) or
- Until Freezer Defrost sensor is below -27c.
( If Error F3 happens, Precool is over. )
- Until Freezer Defrost Sensor is 13c.
- If Error F3 happens, Defrost Heater is active for 30 minutes.
- For 30 sec. after Defrost start : Heater is on without conditions.
- 30 min.'s Defrost : When Error F3 happen.
- 80 min.'s Defrost : Normal state, maximum defrost time.
- For 10 min.
- Defrost heater, Comp. and Freezer / Refrigertor Fan is off.
- For 5 min.
- Compressor is on, Heater is off.
Defrost
Precool
Heater Defrost
Pause
Fan Motor Delay
2. Refrigerator Defrost Process
- Until Ref. Defrost sensor is 20c.
- If maximum time is 60 min. Error R3 happen.
- Ref. Defrost sensor is abnormal, Heater is on for 10 min. ( Maximum time limit )
- For 30 sec. after Defrost start : Heater is on without conditions.
- 10 min.'s Defrost : When Error R3 happen.
- 60 min.'s Defrost : Normal state, maximum defrost time.
- For 10 min.
- Defrost heater, Comp. and Freezer / Refrigertor Fan is off.
- For 5 min.
- Compressor is on, Heater is off.
Heater Defrost
Pause
Fan Motor Delay
11