1. Plug-in Defrost
1) When Freezer & Refrigerator Defrsot sensor is below 3.5c, Defrost mode start.
2) Freezer and Refrigerator compartment defrost start by defrost sensor.
3) Plug-in Defrost makes Compressor Delay 6 min.
2. Pull Down Mode
1) How to start?
- Push the Lock button to enter test mode.
- Push the Lock button 10 times while holding the Ref. Set button.
2) Control : Compressor and all Fan motor is on and Step Valve is Open / Open for 30 hours.
3) Display : 'C o' display on the FCP. ( Need to enter Error Display Mode )
4) How to exit this mode : After 30 hours or Plug-out.
3. Compressor RPM Control
1) Compressor RPM is dependent on RT (Room Temperature ), appliance state ( Dial setting ) and Step Valve position.
Plug-in Defrost / Pull Down / Compressor RPM
RT sensor is below 29.1c
RT sensor is 29.1 ~ 36.5c
RT sensor is over 36.5c
2) Initial plug-in : For initial 2 minutes, compressor rpm is 1650. And then follow above table.
3) For 6 minutes after compressor is off, it doesn't restart.
Refrigerator
30000 RPM
Mode
Freezer
Refrigerator
Freezer
Refrigerator
Freezer
2360 RPM
3490 RPM
30000 RPM
3490 RPM
Normal
1830 RPM
3000 RPM
2360 RPM
3490 RPM
30000 RPM
Quick
2360 RPM
2360 RPM
3490 RPM
30000 RPM
3490 RPM
30000 RPM
Load Response
2360 RPM
3490 RPM
Power Saving
1650 RPM
-
Pull Down
3490 RPM
3490 RPM
3490 RPM
3490 RPM
3490 RPM
14