5. Troubleshooting when error display
8) 'd 2' display ( No error )
- Display A/s Defrosting is operating.
9) 'C o' display ( No error )
- Display Pull Down Mode is operating.
10) 'r d' error
- Cause : Refrigerator defrost sensor disconnection or short.
- Control : Defrost heater is ON for 10 minutes.
11) 'H 5' error
- Cause : Humidity sensor disconnection or short.
- Control : Discard all signal from the humidity sensor.
12) 'r 2' error
- Cause : Multi Crisper room sensor disconnection or short.
- Control : Short - continuous operation. Disconnection - No operation.
13) 'F 3' error ( Freezer Compartment )
- Cause : Defrosting is active for 80 minutes ( maximum limit time ).
- Control : Reduce defrosting operation time to 30 minutes.
14) 'r 3' error ( Refrigerator Compartment )
- Cause : Defrosting is active for 60 minutes ( maximum limit time ).
- Control : Reduce defrosting operation time to 10 minutes.
15) 'F u' error
- Cause : Pipe blockage in freezer compartment. It doen't make any cold air in freezer room.
- Control : Normal operation.
16) 'R u' error
- Cause : Pipe blockage in refrigerator compartment. It doen't make any cool air in refrigerator room.
- Control : Normal operation.
16) 'C H' error
- Cause : Each freezer & refrigerator pipe wrong assembly.
- Control : Normal operation.