1. Buzzer
1) When FCP buttoning.
2) After 3 seconds plug-in.
3) When Pull Down or A/S Defrosting start.
4) Every 1 minute with door opening for 5 minutes.
2. Electric parts time delay
1) Compressor / All Fan Motor
- Check Step Valve position and after 90 seconds compressor start.
( But, after 5 seconds from iniitial plug-in compressor start. )
Other Functions
OFF
OPEN
90 seconds
OFF
ON
Step Valve
Compressor
2) Frz. / Ref. Fan Motor time delay is 20 seconds when door opening.
( This function is active after 2 hours' plug-in. )
3) Frz. Fan Off : After 3 minutes from Off condition.
4) Ref. Fan Off : After 3 minutes from Off condition.
3. Step Valve Control
1) Set the starting Point : Rotate CW) 210 step and CCW) 154 step when initial plug-in.
2) Compressor is ON after 90 seconds from Step Valve when compressor active condition happen.
3) Step valve rotate 34 step ( Close / Close ) after 2 seconds from compressor is OFF.
0.5 second
OFF
ON
OFF
ON
3.5 seconds
Comp.
Fan Motor
Frz. / Ref.
Fan Motor
OFF
Frz. Compartment
Close
Close
Open
Open
Ref. Compartment
Close
Open
Open
Close
Division
34 Step
100 Step
154 Step
195 Step
15