E6&E7 tree
Inspection
-
>
E6
Open-circuit failure of
thermistor
Check whether the NTC
circuit is correct or not.
(mentioned in section 4)
Reconnect the wire of
Flowmeter circuit and
check again
Not
solve the problem
OK
Replace the NTC to
solve problem
Still wrong
E7
Short-circuit failure of
thermistor
Check whether the NTC
circuit is correct or not.
(mentioned in section 4)
Reconnect the wire of
Flowmeter circuit and
check again
Not
solve the problem
OK
Replace the NTC to
solve problem
Still wrong
If the problem has not been solved through all the inspection mentioned
above, maybe the PCB has a malfunction. So, replace PCB and test again.
Caution:
Because the real situation is unpredictable, inspection trees mentioned in this
manual are for reference only.
54
Содержание EGSP-130E
Страница 4: ...Installation instructions 2 Models EGSP 130E EGSP 13E EGSP 90E EGSP 9E 3 ...
Страница 9: ...Exploded view Function Description 8 EGSP 130E 2006 ...
Страница 10: ...Exploded view Function Description 9 EGSP 130E 3013 3018 3017 3014 ...
Страница 15: ...Exploded view Function Description 14 EGSP 13E 2006 ...
Страница 16: ...Exploded view Function Description 15 EGSP 13E 3013 3018 3017 3014 ...
Страница 20: ...19 Exploded view Function Description EGSP 90E 1115 1117 1114 1113 1116 1074 a 1023 ...
Страница 21: ...20 Exploded view Function Description EGSP 90E 2006 ...
Страница 22: ...21 Exploded view Function Description EGSP 90E ...
Страница 26: ...25 EGSP 9E Exploded view Function Description 1115 1117 1114 1113 1116 1074 a 1023 ...
Страница 27: ...26 EGSP 9E Exploded view Function Description 2006 ...
Страница 28: ...27 EGSP 9E Exploded view Function Description ...