Inspect heater
1. Remove bottom board.
2. Use the multi-meter
shelf to measure
resistance between the two terminals shown in right
picture, the resistance is about 29
to 31 .
3. If the measured resistance is not correct, it
means the heater coil or the thermostat is broken,
we should replace the heating element or the
thermostat.
Ω
Ω
Ω
Heater
Theory of parts
-
>
B
View
ottom
Access heater
1. Drain off the water in the dishwasher, and disconnect the power supply.
(Note : Make sure to remove remained water in the dishwasher. If not, wet the
floor)
2. Remove bottom board.
3. Label and disconnect the terminals to and ground wire.
4. Remove the 2 clamps from the Heating element.
Caution: The clamp is easily damaged during removal and can
’
t be reused.
Replace the old clamp with a new universal clamp .
5. Reverse the above procedure to install.
Clamps
Ground terminal
Terminals
(measure heater resistance)
terminals
40
Содержание EGSP-130E
Страница 4: ...Installation instructions 2 Models EGSP 130E EGSP 13E EGSP 90E EGSP 9E 3 ...
Страница 9: ...Exploded view Function Description 8 EGSP 130E 2006 ...
Страница 10: ...Exploded view Function Description 9 EGSP 130E 3013 3018 3017 3014 ...
Страница 15: ...Exploded view Function Description 14 EGSP 13E 2006 ...
Страница 16: ...Exploded view Function Description 15 EGSP 13E 3013 3018 3017 3014 ...
Страница 20: ...19 Exploded view Function Description EGSP 90E 1115 1117 1114 1113 1116 1074 a 1023 ...
Страница 21: ...20 Exploded view Function Description EGSP 90E 2006 ...
Страница 22: ...21 Exploded view Function Description EGSP 90E ...
Страница 26: ...25 EGSP 9E Exploded view Function Description 1115 1117 1114 1113 1116 1074 a 1023 ...
Страница 27: ...26 EGSP 9E Exploded view Function Description 2006 ...
Страница 28: ...27 EGSP 9E Exploded view Function Description ...