Inlet Valve
Theory of parts
-
>
1. Left side panel
2. Middle rear
crosspiece
Inlet valve
Access inlet valve
1. Disconnect power.
2. Remove the water inlet hose. (Note : Be careful of remain water drop.)
3. Remove the left baseboard and middle rear crosspiece.
4. Disconnect the 2 terminal
lugs from the inlet valve.
5. Push the valve from the
lower rear crosspiece to take
it off.
6. Remove the clamp and
disconnect the inlet hose (to
air breaker) from the water
valve.
7. Reverse the above
procedure to install.
1.Open the control panel and take out the PCB;
2.Unplug the CON3 and P4 wires , then use the
multi-meter
shelf to measure resistance
between the blue wire (EV1) and white wire (IS),
the normal resistance is about 3.4K
to 4.3 K .
3. I f the measured resistance is not correct, it
means the valve coil is broken or the connector
is loose. In this case, we should check the
connection first. If the problem hasn
’
t been
solved by re-connection, we should replace the
valve..
4.If the resistance is OK, we need to inspect the
valve body.
Ω
Ω
Ω
Inspect inlet valve
unplug
IS
Ev1
Check electric part
35
Содержание EGSP-130E
Страница 4: ...Installation instructions 2 Models EGSP 130E EGSP 13E EGSP 90E EGSP 9E 3 ...
Страница 9: ...Exploded view Function Description 8 EGSP 130E 2006 ...
Страница 10: ...Exploded view Function Description 9 EGSP 130E 3013 3018 3017 3014 ...
Страница 15: ...Exploded view Function Description 14 EGSP 13E 2006 ...
Страница 16: ...Exploded view Function Description 15 EGSP 13E 3013 3018 3017 3014 ...
Страница 20: ...19 Exploded view Function Description EGSP 90E 1115 1117 1114 1113 1116 1074 a 1023 ...
Страница 21: ...20 Exploded view Function Description EGSP 90E 2006 ...
Страница 22: ...21 Exploded view Function Description EGSP 90E ...
Страница 26: ...25 EGSP 9E Exploded view Function Description 1115 1117 1114 1113 1116 1074 a 1023 ...
Страница 27: ...26 EGSP 9E Exploded view Function Description 2006 ...
Страница 28: ...27 EGSP 9E Exploded view Function Description ...