41
8. TR
OUBLE SHOO
TING
Outdoor unit does
not run?(note. 1)
Does
the compressor run
normally?
Indoor unit does
not run(note 1)
Check the failure
code according to
the self diagnostic
(note 2)
Is the unit
display
mormal?
check the failure
code according to
the self-diagonostic
(note 2)
Normal
check the
connecting
point of
magnetic
contactor
YES
YES
YES
YES
NO
NO
YES
Trouble
Is the power
applied to the
unit
Is the
power normal?
check the voltage between
Y & L of terminal
block
press the power ON/OFF
button on remote controller
Does the
beeper beep two
times?
Is the display
all off?
• Check the connector on display
PCB connected to control PCB
• Check the display PCB itself
Check power supply mains
or interconnection wires
Check the wiring of indoor
Is the
switch position
on switch pannel at
"Remote"
Does
control PCB
status LED repeat one
second "on and
off"?
• control PCB fault
• Micom or reset
IC fault
• Check the remote signal receiver
• Check the connection between signal
receiver and control PCB
Place the switch
position to the
"Remote" and then
Check it once
more
YES
NO
YES
NO
NO
NO
NO
YES
YES
YES
YES
YES
NO
NO
NO
Is the
unit display
normal?
Содержание DMB-1812LH
Страница 36: ...36 5 WIRING DIAGRAM ...
Страница 47: ...PCBDRIVINGDESCRIPTION ...
Страница 48: ...1 PCB CIRCUIT DIAGRAM DMB 1812LH Outdoor ...
Страница 49: ......
Страница 50: ...DMB 1812LH 12K ...
Страница 51: ......
Страница 52: ...DMB 1812LH 9K ...
Страница 53: ......
Страница 77: ...74 6 U9 KIA7042P RESET IC KIA70 42P OUTLINE INPUT GROUND OUTPUT VCC 1 3 2 OUT GND ...
Страница 81: ...78 3 EXPLODED DIAGRAM Indoor Unit DMB 1812LH 9K ...
Страница 83: ...80 DMB 1812LH 12K ...
Страница 86: ...83 4 EXPLODED DIAGRAM Outdoor Unit DMB 1812LH ...
Страница 88: ...85 5 CONTROL BOX ASSEMBLY DMB 1812LH 9K ...
Страница 90: ...87 DMB 1812LH 12K ...
Страница 92: ...89 DMB 1812LH Outdoor ...