DMB-1812LH(12000BTU/h)
NOTES:
• This appliance must be installed according to National power supply requirement.
• If the supply cord is damaged, it must be replaced by the manufacuturer or its service agent or a similarly qualified per-
son in order to avoid a hazard.
• Make sure the Indoor unit’s AC cord is not connected to AC power when connecting the indoor/outdoor wire.
• When connecting wires, make sure they are fully inserted and minimum copper wire is exposed. If they are not, short-
ing, overheating, no operation, etc. may occur.
• Be sure to comply with local codes on running a wire from the indoor to the outdoor unit.
1. Open the connection cover on the indoor unit to
access the connection area.
Remove the Connection Cover.
• Loosen two screws for fixing
the Connection Cover.
• Loosen two screws at the
Connection Cover.
• Remove the Connection
Cover.
2. Fish the indoor/outdoor wire from the rear of the
indoor unit through the front of the unit.
For easier connection, make sure enough wire is
pulled through the front.
Use the wire as shown below:
Blue
Yellow/Green
Brown
The Indoor/Outdoor wire is used to supply AC from the Indoor unit to the Outdoor unit. To install the indoor/outdoor wire,
follow the procedures below.
Connection cover
Screw (Special screw)
3. To connect wires, loosen the screw in the Terminal Block
and insert the correct wires like following figure.
Connect the Brown wire to the “Y” connection,
Yellow/Green wire to the “ ”connection and the
Blue wire to “L” connection.
Y
L
Brown
Blue
Yellow/Green
DMB-1812LH
(12000BTU/h)
DMB-1812LH(12000BTU/h)
12
Remove the Connection
Cover.
• Loosen the screw fixed at
the Connection Cover.
• Remove the
Connection Cover.
Содержание DMB-1812LH
Страница 36: ...36 5 WIRING DIAGRAM ...
Страница 47: ...PCBDRIVINGDESCRIPTION ...
Страница 48: ...1 PCB CIRCUIT DIAGRAM DMB 1812LH Outdoor ...
Страница 49: ......
Страница 50: ...DMB 1812LH 12K ...
Страница 51: ......
Страница 52: ...DMB 1812LH 9K ...
Страница 53: ......
Страница 77: ...74 6 U9 KIA7042P RESET IC KIA70 42P OUTLINE INPUT GROUND OUTPUT VCC 1 3 2 OUT GND ...
Страница 81: ...78 3 EXPLODED DIAGRAM Indoor Unit DMB 1812LH 9K ...
Страница 83: ...80 DMB 1812LH 12K ...
Страница 86: ...83 4 EXPLODED DIAGRAM Outdoor Unit DMB 1812LH ...
Страница 88: ...85 5 CONTROL BOX ASSEMBLY DMB 1812LH 9K ...
Страница 90: ...87 DMB 1812LH 12K ...
Страница 92: ...89 DMB 1812LH Outdoor ...