33
in case of operating two units
the operation mode of the remote controller
As shown above, When the "modes I" is selected, only the indoor unit which is received the first signal from
the remote controller operates and the other indoor unit doesn't operate.
also, you can see the blink of indicators of the latter.
in that case, try to select one out of the "modes II" again.
(2) Selecting Operating Mode Again
Room temperature meets desired temperature and the compressor stops running over 30 minutes, then the unit
selects operating Mode again.
3 min. Time Delay of Compressor
In normal operation, there is a time delay of three minutes between turn off and turning back on including initial
power up.
(RT: Room temperature)
(1) When the remote controller is lost, damaged or the battery is discharged, the Emergency operation can be
used to run the unit.
(2) The setting conditions of Emergency operation are as follows.
• Operation mode: Quick
• Preset temperature:18°C: Cooling, 32°C: Heating)
• Fan speed: High
You cannot operate with remote controller.
Emergency Operation
ROOM TEMPERATURE
DT-2°C RT
DT-2°C
≤
RT
≤
DT+3°C
DT+3°C RT
OPERATING MODE
Heating
Dehumidifier
Cooling
FLAP POSITION
Heating Position
Cooling Position
Cooling Position
>
<
Modes I
Modes II
indoor unit A Fan
Heating Cooling Heating Fan
Cooling Cooling Cooling
Dehumidification Heating
indoor unit B Heating Fan
Heating Cooling Cooling Fan
Cooling Dehumidification Cooling
Heating
Operation
No Good
Good
Содержание DMB-1812LH
Страница 36: ...36 5 WIRING DIAGRAM ...
Страница 47: ...PCBDRIVINGDESCRIPTION ...
Страница 48: ...1 PCB CIRCUIT DIAGRAM DMB 1812LH Outdoor ...
Страница 49: ......
Страница 50: ...DMB 1812LH 12K ...
Страница 51: ......
Страница 52: ...DMB 1812LH 9K ...
Страница 53: ......
Страница 77: ...74 6 U9 KIA7042P RESET IC KIA70 42P OUTLINE INPUT GROUND OUTPUT VCC 1 3 2 OUT GND ...
Страница 81: ...78 3 EXPLODED DIAGRAM Indoor Unit DMB 1812LH 9K ...
Страница 83: ...80 DMB 1812LH 12K ...
Страница 86: ...83 4 EXPLODED DIAGRAM Outdoor Unit DMB 1812LH ...
Страница 88: ...85 5 CONTROL BOX ASSEMBLY DMB 1812LH 9K ...
Страница 90: ...87 DMB 1812LH 12K ...
Страница 92: ...89 DMB 1812LH Outdoor ...