background image

11

Preparation and Setup

Preparing the Mounting Location

Holding brackets and hardware are provided to temporarily 

hold the hood in place while you permanently fasten the 

hood to the wall.
The illustrations below show the purpose of the holding 

brackets and the support behind the wall. 
1.  If mounting the hood to brick or masonry, select 

anchors capable of  holding the full weight of the hood.

2.  Make sure the mounting surface is properly reinforced 

to support the full weight of the unit.

•  If mounting the unit to drywall or a plastered surface, 

install a reinforced mounting block between the studs. 

•  Attach screws directly to the studs and cabinets if they 

align with the mounting holes in the back and top of the 

hood. 

Holding 

Brackets

(Enlarged for Detail)

Support Block 

Model

Weight

RNHP3012

51 lbs. (23 kg)

RNHP3018

RNHP3612 

53 lbs. (24 kg)

RNHP3618 

57 lbs. (26 kg)

RNHP4812 

70 lbs. (32 kg)

RNHP4818

77 lbs. (35 kg)

Stud

Stud

Support Structures Behind the Wall

Holding Brackets

 WARNING

•  The electricity to the range hood should be installed 

only by a licensed electrician.

•  Observe all governing codes and ordinances during 

site preparation and installation. Contact your local 

building department for further information.

•  Failure to properly anchor the hood to the wall may 

result in personal injury due to the unit falling off the 

wall.

•  To avoid an electric shock hazard and property dam-

age, locate electric wires and water pipes and avoid 

drilling or cutting in the vicinity.

•  Use the 

temporary

 holding brackets only to hold the 

hood in place until permanent anchoring is secured.

Содержание RNHP36 Renaissance

Страница 1: ...oods Models RNHP30 RNHP36 and RNHP48 Part No 109172 Rev A APPROVED FOR USE WITH ALL DACOR RANGES AND COOKTOPS TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI UL 507 STANDARD FOR ELECTRIC FANS AND...

Страница 2: ...nstructions completely and carefully before you begin the installation process Leave these installation instructions with the consumer Write the Data Plate Information in the Use and Care Manual befor...

Страница 3: ...amage personal injury or death WARNING WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Use this unit only in the manner intended by the manufacturer If y...

Страница 4: ...appliance only as instructed in the Use and Care Manual Use only the cleaners specified Do not tamper with the controls Never allow the filters to become blocked or clogged Do not allow foreign object...

Страница 5: ...s Model Number RNHP48 RNHP36 RNHP30 Lights 4 3 2 Filters 4 3 2 Blowers 2 1 1 Exhaust Vents 2 1 1 Blower Rating 1200 CFM 600 CFM 600 CFM Product Specifications Model Weight RNHP3012 51 lbs 23 kg RNHP30...

Страница 6: ...holes 7 8 in dia 5 1 cm C A Dual Exhaust Models Standard 8 inch duct Single Exhaust Models Standard 8 inch duct Bottom of hood C Electrical access holes 7 8 in 5 1 cm diameter 19 3 4 in 50 2 cm Conne...

Страница 7: ...3018 29 7 8 75 9 cm 24 61 cm 18 45 7 cm 11 7 8 30 2 cm RNHP3618 35 7 8 91 1 cm RNHP4818 47 7 8 121 6 cm Top Access Holes A B C RNHP48 1 1 2 3 81 cm 5 12 7 cm 3 7 62 cm RNHP36 1 1 2 3 81 cm 4 1 2 11 43...

Страница 8: ...s and hardware are within reach before beginning the installation pictures vary by model Blower Rotation optional Phillips screwdriver 5 16 Nut driver Hood Model RNHP48 RNHP36 RNHP30 LED Lights 4 3 2...

Страница 9: ...electrician Do not ground the appliance or appliance wiring to a gas pipeline or to the neutral white power supply wire Do not install a fuse in the neutral or ground circuit Connect the hood directl...

Страница 10: ...ations for the cooktop or range E 30 min 76 2 cm Electrical access From cooking surface top rear E Minimum Width of E Upper Cabinet Cutout Appliance Width Models E RNHP3012 RNHP3018 30 inches 76 2 cm...

Страница 11: ...s water heat ers and fireplaces To avoid drawing lethal gases into the home follow the manufacturer s recommendation for these devices and consult NFPA and ASHRAE rec ommendations Failure to install a...

Страница 12: ...etup Ductwork Tips Wherever possible reduce the number of transitions turns and sharp angles Two staggered 45 angles are better than one sharp 90 angle Keep turns as far away from the hood exhaust as...

Страница 13: ...les in the back and top of the hood Holding Brackets Enlarged for Detail Support Block Model Weight RNHP3012 51 lbs 23 kg RNHP3018 RNHP3612 53 lbs 24 kg RNHP3618 57 lbs 26 kg RNHP4812 70 lbs 32 kg RNH...

Страница 14: ...or example if it is a top vent installa tion set the hood with the vents on top 2 Measure the distance from the edge of the hood to the center of the exhaust port 3 Transfer that measurement to the wa...

Страница 15: ...with the horizontal centerline Make sure the anchors and or screws being used are strong enough to support the hood Make sure drywall installations are properly reinforced 5 Mark the two holes in the...

Страница 16: ...ar Exhaust WARNING Do not install the range hood unless the electrical service provided meets the range hood specifications Observe all governing codes and ordinances during installation Contact your...

Страница 17: ...allation Instructions Removing the Blower s 4 Tip the hood up so that it lays on its back You are now facing inside the hood 5 Find the end of the cable assembly plugged into the bottom left of the bl...

Страница 18: ...ear Exhaust 9 Unscrew and remove the L bracket that is in the default top venting orientation 10 Turn and align the L bracket so the hole is in back of the hood allowing a rear venting configuration c...

Страница 19: ...1 Roll the hood on its top so the tip of the blower can extend beyond the exit vent 12 Insert the blower into the exit vent with this specific placement When standing at the back of the hood and looki...

Страница 20: ...1 Remove the plastic coating and confirm that the inside lip is beveled If this is true proceed If not flip the frame 2 Align the screw lock washer and knob with the filter Make sure the knob is on th...

Страница 21: ...TANT Rear vent 12 inch tall hood configurations keep one of the long edges straight 12 inch tall hoods are models 3012 3612 4812 Bending the Flange for Top Vent Configuration None Rear Only Rear Vent...

Страница 22: ...3018 3618 4818 18 inch height requirement 1 Drill holes for screws in the flanges Make sure the holes pierce the rear of the hood see right 2 Center the AHT10 transition kit over the duct collars 3 Fa...

Страница 23: ...ts final position 4 Mark the spot by drawing in a mounting hole in the back of the hood see figure Hanging and Mounting Slots This is where a screw will hold the hood to the wall stud or concrete anch...

Страница 24: ...ted circuit See Wire Diagrams Control Panel Wire Diagram Hardwiring the Hood WARNING To avoid electric shock or fire hazard prior to connecting the electrical wiring to the hood make sure that power t...

Страница 25: ...n cup to the lens of a dimmable light bulb Both are supplied parts Make sure the bulb faces are clean so the suction cup can stick 2 Insert the bulb into one of the light fixtures 3 Screw it into plac...

Страница 26: ...on at low speed 9 Slowly touch and release the FAN button three times Verify that with each touch the number of lights rises and that the fan speed increases 10 Press the FAN button again to turn the...

Страница 27: ...rding to the instructions on page 13 and 21 Is the ductwork completely installed Are all joints attached with sheet metal screws and wrapped with foil tape See page 19 Is the range hood wired and grou...

Страница 28: ...0 9 8 7 6 5 4 3 2 1 HOOD LIGHT 75W HOOD LIGHT 75W CLEAN FILTER LED INDICATOR RESISTOR 620 1 4W 2 3 4 FAN SPEED LED INDICATOR RESISTOR 3 6K 1 4W 3 4 FAN SW 4 3 4 3 LIGHT SW TIMER SW CAUTION DISCONNECT...

Страница 29: ...6 5 4 3 2 1 HOOD LIGHT 75W HOOD LIGHT 75W HOOD LIGHT 75W CLEAN FILTER LED INDICATOR RESISTOR 620 1 4W 2 3 4 FAN SPEED LED INDICATOR RESISTOR 3 6K 1 4W 3 4 FAN SW 4 3 4 3 LIGHT SW TIMER SW CAUTION DIS...

Страница 30: ...1 10 9 8 7 6 5 4 3 2 1 HOOD LIGHT 75W HOOD LIGHT 75W HOOD LIGHT 75W CLEAN FILTER LED INDICATOR RESISTOR 620 1 4W 2 3 4 FAN SPEED LED INDICATOR RESISTOR 3 6K 1 4W 3 4 FAN SW 4 3 4 3 LIGHT SW TIMER SW W...

Страница 31: ...29 Notes...

Страница 32: ......

Страница 33: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...

Отзывы: