22
Installation Instructions
GREEN
GREEN
WHITE
WHITE
BLACK
BLACK
Junction Box Wire Diagram
UL/CSA approved
NEMA strain relief
To house circuit breaker
or fuse box
To Range Hood
Junction box
Wire nut,
3 places
L1
N1
Gnd
Not used
To Junction
Box
Power
Terminals
inside Hood
Ground (green)
Neutral (white)
Hot (black)
1. Shut power OFF at the circuit breaker or fuse box.
2. Feed the cable assembly through the hood.
3. Connect the cable assembly to the blower.
4. Connect the hood wiring to an electrical junction box on a dedicated circuit. See Wire Diagrams.
Control Panel Wire Diagram
Hardwiring the Hood
WARNING
• To avoid electric shock or fire hazard, prior to connecting the electrical wiring to the hood, make sure that power to
the hood power supply line is turned off at the fuse box or circuit breaker panel.
• Improper connection of the hood electrical wiring may create an electric shock or fire hazard and may result in dam-
age to the hood’s electrical system. See page 7 for specifications.
• Do not ground the hood to the neutral (white) power supply wire. Connect the hood ground wire to a separate, prop-
erly grounded wire installed by a licensed electrician.
• Make sure all wire used is capable of handling the total connected load. See page 3.