Installing the Rangetop, cont.

The gas shut-off valve should be installed on the gas 

piping, away from the rangetop, easily accessible for 

quick opening/closing.

Checking for Gas Leaks

Connecting the Gas Supply, cont.

Never install an old connector on a new appliance. For hard piping, carefully align the pipe; the rangetop can-

not be moved after the connection is made.
To prevent gas leaks, apply pipe-joint compound or wrap pipe-thread tape with Teflon on all male (external) 

pipe threads.

1.  Attach the provided gas-pressure regulator to the rangetop pipe nipple inlet. (For tight installations, the 

regulator may be installed upstream from the nipple, anywhere between the shut-off valve and the range-

top. For best performance, minimize gas-pressure loss by attaching the regulator as close as possible to 

the gas inlet.

2.  Complete the connection by installing a flexible gas line between the pressure regulator and the shut-off 

valve.

Flexible Connector Hookup

Installer: Inform the consumer of the location of the gas shut-off valve.

To prevent an explosion/fire hazard possibly leading to personal injury or death, DO NOT use a flame to check 

for gas leaks.
When using pressures above 1/2 psig to test the home gas-supply system, disconnect the rangetop and indi-

vidual shut-off valve from the supply line. When testing with pressures of 1/2 psig or less, isolate the rangetop 

by closing the individual shut-off valve.
1.  When all connections are made, ensure all rangetop controls are OFF, and turn on the main gas- supply 

valve.

2.  Use a liquid leak detector at all joints.
3.  Tighten connections as needed to prevent gas leakage in the rangetop or supply line.

Содержание DTT48M876 Series

Страница 1: ...Installation Instructions Modernist Rangetop DTT48M876 DTT36M876 Part No 115115 Rev A...

Страница 2: ...cifications 9 What Is In the Box 9 Parts and Tools Needed 10 Installation Requirements 11 In Preparation 11 Overall Rangetop Dimensions 12 Countertop Cutout Dimensions 13 Gas Supply Requirements 17 Sp...

Страница 3: ...emove all packaging from the rangetop before connecting it to the electric gas supplies Observe all governing regulations Installation requires basic mechanical skills The installershall ensure proper...

Страница 4: ...CustomerAssurance Team Before calling have the rangetop s model serial numbers available see the data label right hand side of the rangetop chassis DacorCustomerAssurance Phone 800 793 0093 x2813 USA...

Страница 5: ...s This product must be installed by a licensed plumberorgas fitterqualified orlicensed by the State of Massa chusetts When using ball type gas shut off valves you must use the T handle type Multiple f...

Страница 6: ...afety To reduce risk of property damage fire personal injury and death Do not store place use combustible items e g paper plastic fabrics gasoline nearthe range Do not wearloose fitting orhanging garm...

Страница 7: ...operpath forthis ground wire Electrical service to the rangetop must conform to local codes in the absence of which it should meet the latest ANSI NFPA No 70 Latest Revision forthe U S orthe Canadian...

Страница 8: ...xide poisoning do not use cookware that is substantially largerthan the grate Turn cookware handles away from surface burners and the rangetop front edge Stand back from the range while frying Heat fr...

Страница 9: ...te rangetop Porcelain and brass burnercaps are provided to suit customerpreference The brass will discolorwith use however the discoloration does not affect the caps intended function If you need an a...

Страница 10: ...onnector in ID x 5 ft Flare union adapter in NPT x in ID Flare union adapter in NPT x in ID 135 degree elbow option 90 degree elbow option Flat blade screwdriver Phillips screwdriver Open end or adjus...

Страница 11: ...to meet the specified parameters The rangetop complies with the maximum allowable wood cabinet temperature of194 F 90 C Ensure the wall covering countertops and surrounding cabinets can withstand this...

Страница 12: ...12 English Installation Requirements DTT36M876 DTT48M876 36 91 1 cm 48 121 6 cm...

Страница 13: ...s Countertop Cutout Dimensions Installed Rangetop side view Cabinet Countertop Dimensions front view Cutout dimensions must be observed Any overage could be create severe problems Cabinet tolerances 1...

Страница 14: ...ertop Cutout Dimensions cont Installed Rangetop side view Cabinet Countertop Cutout Dimensions No Downdraft Vent top view Rangetop Model A B C DTT36M876L 36 91 4 cm 35 88 9 cm 16 5 8 42 2 cm DTT48M876...

Страница 15: ...connections must be routed through the bottom of the rangetop when installed with a downdraft vent Model A Cutout Width B Hole Offset C Downdraft Vent Cutout Approved Downdraft Vent Models DTT36M876L...

Страница 16: ...out Dimensions cont Cabinet Countertop With Downdraft Vent side view Utility Locations and Dimensions rear Dimension DTT36M876L DTT48M876L D 3 1 2 8 9cm 4 10 1cm E 4 11 16 11 9cm 4 11 16 11 9cm F 5 1...

Страница 17: ...as inlet to the shut off valve An external manual shut off valve must be installed between the gas inlet and rangetop forturning on off gas to the appliance Have a qualified technician install the con...

Страница 18: ...box All gas models are equipped with a powercord with an equipment grounding conductorand a ground ing plug All gas models in the US and Canada require a120 V 60 Hz AC approved electrical service with...

Страница 19: ...Supply 1 Shut off the main gas supplyvalve before disconnecting the old rangetop 2 Complete the gas hookup 3 Open the gas valve and relight the burners on any othergas appliances Because hard piping r...

Страница 20: ...est performance minimize gas pressure loss by attaching the regulatoras close as possible to the gas inlet 2 Complete the connection by installing a flexible gas line between the pressure regulatorand...

Страница 21: ...er cord Ensure the outlet meets all applicable electrical codes see pg 18 2 After installing the rangetop check the gas supply line to verify it was not damaged and remains connected Assembling the Ra...

Страница 22: ...Round BurnerHead Caps 1 Orient the burner head so the opening forthe elec trode aligns with the electrode 1 Put the burnerheads on the burnerbases The bottom of the head fits within the burnerbase 2...

Страница 23: ...rner rings The ridge around the bottom edge of the cap fits around the top of the ring Verifying BurnerFunction Afterthe cooktop is fully installed and plugged in make sure all burners work properly 1...

Страница 24: ...ng the Grates Forbest results and longest life install the grates as instructed The grates occupy specific positions on the rangetop and should only be used in those positions To help with installatio...

Страница 25: ...ngetop is properly installed and ready to operate The gas line was properly connected to the rangetop The gas was turned on All connections were checked forleaks The rangetop is properly plugged in to...