Installation Requirements
In Preparation
1. Before cutting the opening in the countertop, verify that there will be no conflict between the rangetop
chassis and anything in the cabinet below.
2. Remove all packing material and accessories from the rangetop, and verify that all items are present
before beginning the installation.
Location Requirements
Before
you begin the nstallation, review this section thoroughly. These dimensions must be met for safe oper-
ation. Location of the electrical outlet and gas piping may be adjusted to meet the specified parameters.
The rangetop complies with the maximum allowable wood-cabinet temperature of 194 °F (90 °C). Ensure the
wall covering, countertops, and surrounding cabinets can withstand this temperature to avoid discoloration,
delamination, or melting.
¹Vertical to combustible surface from
rangetop grate level; if installing a venti-
lation hood, check hood spec's for mini-
mum required clearances.
²See Cabinet/Countertop Dimensions
– Top View.
³This specification is not applicable for
cabinets more than a horizontal distance
of 10" (25.4 cm) from the edge of the
rangetop.
Rangetop
DTT36M876L*
DTT48M876L*
A
36" (91.41 cm)
48" (121.9 cm)
B
36" (91.41 cm)*
42" (106.7 cm)**
48" (121.9 cm)*
54" (137.2 cm)**
* Minimum
** Recommended
A: Rangetop cutout
B: Range hood cutout