background image

 

 

 
GENERAL

 

INFORMATION

 

 

User Responsibility 

 
DABOTEK  Welding  warrants  that 

The  DT1200i

  will  perform  in  accordance  with  the  product 

description in this manual.  

 

The Factory Warranty will be null and void should the user attempt 

to  operate 

The  Studhorse 

after  it  has  malfunctioned.    Parts  that  are  broken,  missing  or  worn 

must  be  replaced  immediately.    DABOTEK  Welding  Equipment  LLC  or  its  Authorized  Repair 
Center  will  perform  warranty  Repairs.   

The  Studhorse 

or  any  of  its  parts  must  not  be  altered 

without  the  prior  written  approval  of  DABOTEK  Welding  Equipment  LLC.    Any  malfunction 
resulting  from  improper  use,  faulty  maintenance,  physical  damage,  unapproved  repair  or 
alteration, shall be the sole responsibility of the user or owner

.

 Any repair to improperly used or 

abused equipment by DABOTEK Welding Equipment LLC will be charged based on DABOTEK’s 
applicable hourly labor rate and current replacement part prices. 

 

Manufacturer’s Limited Product Warranty 

 
DABOTEK Welding Equipment’s only warranty is that goods being sold will be free from defects 
in  materials  and  workmanship.    This  express  warranty  is  in  lieu  of  any  other  warranties,  either 
expressed  or  implied,  and  whether  statutory  or  otherwise,  including  any  implied  warranty  of 
merchantability or fitness for a particular purpose. 
 
The Manufacturer’s written warranty for The DT1200i Stud

 

Welder has been included with your 

new machine, and is limited to defect in materials or workmanship. The original purchaser must 
furnish  notice  of  defect  or  failure  to  DABOTEK  Welding  Equipment  or  one  of  DABOTEK’s 
authorized repair centers using an approved Warranty Claim Form.  Forms can be downloaded 
from  the  company  Web  Site  at 

http://www.dabotek.com

.    The  guarantee  against 

corrosion-related failures can be extended to five-years by completing the Registration Form.  
 
Any equipment that has been modified by any party other than DABOTEK Welding Equipment 
LLC, or equipment that has been improperly installed, improperly operated, misused based upon 
industry  standards,  improperly  maintained  or  equipment  which  has  been  used  for  operation 
outside  of  specifications  will  not  be  covered  under  the  manufacturer’s  warranty.    DABOTEK 
Welding Equipment shall in no way be liable for any consequential damages. 
 
DABOTEK Welding  Equipment  reserves  the  right  to  make  engineering  and/or  part  changes  at 
any time, without notice, as improvements in quality or design are made.  Owners and operators 
of  The  DT1200i  should  access  the  company  Web  site  listed  above  to  keep  up-to-date  with 
offerings, applications and technical suggestions. 
 

SAFETY

 

STANDARDS 

 

The DT1200i 

is designed and built to comply with the following safety standards: 

Underwriters Laboratories Standard 

 

UL551 

Safety 

 

 

 

EN 60974-1 

Degree of Enclosure Protection 

 

IP 24 in accordance with ISO 60529 

  Protection against full penetration of solid foreign objects of 12.5mm diameter and larger. 

  Protection against harmful effects from splashing water against the enclosure from any 

direction. 

Содержание DT1200i

Страница 1: ...OTEK Birkedam 10 C DK 6000 Kolding Denmark Tlf 45 7550 5666 Fax 45 7550 4795 sales dabotek com www dabotek eu DABOTEK DT1200i P N 101201 1200 Amp Drawn Arc Stud Welder OPERATING MANUAL REVISED MARCH 2...

Страница 2: ...t is in conformity with the requirements of the Low Voltage Directive 73 23 EEC and Machinery directive 89 392 EEC 91 368 EEC 93C 133 04 93 68 EEC Compliance Certified by Goran Hedberg Design Engineer...

Страница 3: ...g and Unpacking the Welder 12 3 2 Selecting a Location 12 3 3 Selecting Suitable Supply Cables 12 3 4 Connecting Input Power 12 3 5 Fuse and Circuit Breaker Ratings 13 3 6 Output Connections and Stud...

Страница 4: ...the inverter design Figure 8 1 28 8 2 Main Circuit Diagram 29 8 3 Front Panel Drawing with part references 30 8 4 Rear Panel Drawing with part references 31 8 5 Chassis Plate Drawing 1 with part refer...

Страница 5: ...e and is limited to defect in materials or workmanship The original purchaser must furnish notice of defect or failure to DABOTEK Welding Equipment or one of DABOTEK s authorized repair centers using...

Страница 6: ...mer protected and coated to resist corrosion Output board encapsulated in repair friendly material to eliminate the failures Control board coated to protect against salt water arc over Input board coa...

Страница 7: ...tors must take caution in the method and manner of handling or using the machine when this symbol is displayed 1 2 Safety Precautions Do not install operate or repair The Studhorse welding equipment w...

Страница 8: ...energized supply line before moving a welding power source 9 Always be sure the work cable makes a good electrical connection with the metal being welded The connection should be as close as possible...

Страница 9: ...oatings paper etc 2 Hot sparks or hot metal can fall through cracks or crevices in floors or wall openings and cause a hidden smoldering fire Make certain that such openings are protected from hot spa...

Страница 10: ...to expose themselves to the rays of the electric arc or hot metal 3 Wear flameproof type gloves heavy long sleeve shirt cuff less trousers and a welding helmet or cap for hair protection to protect a...

Страница 11: ...create the suitable welding characteristics The auxiliary transformer steps down the input voltage to 48V center tapped This transformer powers the cooling fan and the control logic 2 3 SAFETY STANDA...

Страница 12: ...l power Use care against toppling over if the machine is placed on a tilted surface or plane It is important that the machine be located in an open area where air can circulate freely through the fron...

Страница 13: ...7 Stud Guns There are several manufacturers of Stud welding guns A Stud gun is shaped to fit in the hand in the shape of a handgun and is a semi automatic stud welding tool Guns vary in design connec...

Страница 14: ...eld power and time adjustment short circuit protection automatic line voltage protection and 5 zones of thermal protection 4 3 Operational Controls and Settings also refer to Figure 4 1 4 3 1 Circuit...

Страница 15: ...t will be 1100 Amps Normally the difference between set and measured is less and only one stud is needed for tuning in process The measured current may fluctuate up to 5 60 Amps 1200 Amps dependent on...

Страница 16: ...ER ON INDICATOR 4 3 1 4 4 4 WELDING CURRENT CONTROL 4 3 3 4 4 1 STUD TIMER CONTROL 4 3 3 4 4 1 CIRCUIT BREAKER POWER ON OFF 4 3 1 OUTPUT TERMINALS 3 6 INPUT POWER CORD 12 FT 3 65m LONG 3 4 GUN CONTROL...

Страница 17: ...m 550A 0 250 3 8 10mm 650A 0 350 1 2 12mm 850A 0 550 5 8 16mm 1200A 0 700 1 If 5 8 inch studs are to be welded set the current timer to 1200 Amps and the timer setting to 0 7 Seconds 2 Shoot weld stud...

Страница 18: ...rmal Protection Control The display will begin blinking if any component is overheating The operator must stop welding Studs and allow the power source to cool down This may take 3 minutes or more dep...

Страница 19: ...uide to visually inspect welded studs to determine the quality of weld The correct relationship between the Lift Plunge Time and Current is essential in order to obtain good weld results Operators sho...

Страница 20: ...20 5 1 Visually Inspecting Welded Studs continued...

Страница 21: ...21 5 1 Visually Inspecting Welded Studs continued...

Страница 22: ...22 5 1 Visually Inspecting Welded Studs continued...

Страница 23: ...23 5 1 Visually Inspecting Welded Studs continued...

Страница 24: ...ing parts other than the fan in the power source basic preventive maintenance only involves keeping the welder clean and free from metallic dust Periodically you should ask your Authorized Service Cen...

Страница 25: ...educe duty cycle 1b Make sure that intake and exhaust vents are not blocked In heavy dust areas clean unit out once per month with compressed air B Circuit breaker trips 1 Over voltage or spikes 2 Inc...

Страница 26: ...air 1 Clean surface 2 Read gun manual for procedure 3 Read gun manual for procedure G Display has fluctuating amperage levels H Display is flashing 1 Unit is self calibrating and will complete calibra...

Страница 27: ...of type X to be allowed to be connected between phases and also to comply with the European community CE norms The type X capacitors are connected to a common point making it a virtual neutral This p...

Страница 28: ...ter Design The inverter function is perhaps easiest understood using the simplified block diagram below AC INPUT FIGURE 8 1 RECTIFIER INVERTER MAIN TRANSFORMER RECTIFIER OUTPUT FILTER CONTROL BOARD AU...

Страница 29: ......

Страница 30: ......

Страница 31: ...1 of 1...

Страница 32: ...1 of 1...

Страница 33: ...1 of 1...

Страница 34: ...1 of 1...

Страница 35: ...001 FAN ASSY 15 011216 001 FAN BLADE 17 011220 002 INDUCTOR OUTPUT 18 011230 001 INDUCTOR MAIN w PTC 19 011241 001 INDUCTOR COMMUTATING FRONT 20 011251 001 INDUCTOR COMMUTATING REAR 21 011272 001 TRAN...

Страница 36: ...1 CLAMP OUTPUT CAPACITOR 65 017102 003 CLAMP INPUT CAPACITOR w PTC BOARD 66 017110 001 BRACKET MOUNTING TRANSFORMER 67 018500 001 JACK OUTPUT DINSE FOR PLASTIC PANEL 68 018500 005 JACK OUTPUT DINSE FO...

Страница 37: ...CAMLOCK WA1200 021 EXTENSION CABLE FOR REMOTE 32FT WA1200 031 WORK CLAMP HEAVY DUTY w 10FT 2 0 CABLE CAMLOCK WAP1200 011 CONNECTOR CAMLOCK MALE FOR CABLE WAP1200 012 CONNECTOR CAMLOCK FEMALE FOR CABL...