ENGLISH
111
on input (NO)
Present
System block due to low pressure
on intake.
Manual reset
F4
13
Active with low signal on
input (NC)
Absent
System block due to low pressure
on intake.
Manual reset
F4
Present
Normal
None
Table 26: Low pressure signal detection (KIWA)
6.6.14
Setup of outputs OUT1, OUT2
This section illustrates the functions and possible configurations of the outputs OUT1 and OUT2 via parameters O1 and O2.
For electrical connections, see section 2.2.4.
The default settings are those in Table 27.
Default output settings
Output
Value
OUT 1
2 (fault NO closes)
OUT 2
2 (Pump running NO closes)
Table 27: Default output settings
6.6.14.1
O1: Output 1 function setting
Output 1 notifies of an active alarm (i.e. that there is a system block). The output enables use of a normally closed or normally open
voltage-free contact. Parameter O1 is associated with the values and functions specified in Table 28.
6.6.14.2
O2: Output 2 function setting
Output 2 notifies of electric pump running status (pump on/off). The output enables use of a normally closed or normally open
voltage-free contact. Parameter O2 is associated with the values and functions specified in Table 28.
Configuration of functions associated with outputs
Output
configuration
OUT1
OUT2
Activation conditions
Output contact status
Activation conditions
Output contact status
0
No function
associated
NO contact always open,
NC contact always closed
No function
associated
NO contact always open,
NC contact always closed
1
No function
associated
NO contact always
closed, NC contact
always open
No function
associated
NO contact always
closed, NC contact
always open
2
Presence of blocking
errors
In event of blocking
errors NO contact closes
and NC contact opens
Activation of output in
event of blocking
errors
When the pump is
running, the NO contact
closes and the NC
contact opens
3
Presence of blocking
errors
In event of blocking
errors NO contact opens
and NC contact closes
Activation of output in
event of blocking
errors
When the pump is
running, the NO contact
opens and the NC
contact closes
Table 28: Output configuration
6.6.15
RF: Fault and warning log reset
To clear the fault and warning log, press and hold the b and – simultaneously for at least 2 seconds. The number of faults
present in the log (max. 64) are summarised below the RF symbol.
The log can be viewed from the MONITOR menu on the FF page.
6.6.16
PW: Password settings
The inverter is equipped with a password protection system. If a password is set, the inverter parameters will be accessible and
readable, but no modifications are admitted.
When the password (PW) is "0" all parameters are unlocked and can be modified.
Содержание PWM 201
Страница 13: ...ITALIANO 11 Figura 2 Fissaggio e distanza minima per la circolazione d aria...
Страница 73: ...ENGLISH 71 Figure 2 Fixture and minimum clearance for air circulation...
Страница 129: ...FRAN AIS 127 Figure 2 Fixation et distance minimum pour la circulation de l air...
Страница 185: ...DEUTSCH 183 Abbildung 2 Befestigung und Mindestabstand f r die Luftzirkulation...
Страница 244: ...ESPA OL 242 Figura 2 Fijaci n y distancia m nima para la circulaci n del aire...
Страница 295: ...293 IEC 60634...
Страница 296: ...294 1 6 1 1...
Страница 300: ...298 1 2 5 2 1 2 1 2 2...
Страница 301: ...299 2...
Страница 302: ...300 2 2 3 3 15 2 2 1 4 2 2 1 1 PWM 203 202 201 3 1 LN 4 2 3...
Страница 306: ...304 6 2 2 3 3 Press e Flow 7 A B C D...
Страница 308: ...306 8 4 20 5 4 20 PR 6 5 7 4 20 2 18 J5 GND 1 J5 GND o IN 11 J5 o OUT 7 J5 4 20 7 OUT 8 10 11 IN...
Страница 311: ...309 DC AC 50 60 8 6 2 1 5 36 36 12 3 3 3 3 2 13 7 11 8 11...
Страница 313: ...311 9 MODE 1 SET 9 3 EEprom SET 6 SET MODE 3 1 11 3 2 1 2 3 2 1 MODE SET MODE 10...
Страница 315: ...313 SO AE MP I1 1 I2 2 I3 3 I4 4 O1 1 O2 2 RF PW 11 3 2 2 13 SET 13 15 14...
Страница 316: ...314 14 3 3 12 GO SB BL LP HP EC OC OF SC OT...
Страница 317: ...315 12 15 13 15 3 4 PW 6 6 16 OB BP NC F1 F3 F4 P1 1 P2 2 P3 3 P4 4 E0 E16 0 16 EE EEprom WARN GO SB...
Страница 318: ...316 4 4 1 Link 8 4 2 4 2 1 Link Link 16...
Страница 319: ...317 16 Link 4 2 2 0 5V 4 20 A 0 4 2 2 1 FI FI 4 2 2 2 FZ 6 5 9 1 4 2 2 3 0 5 4 20 A 0 5 0 5 4 20 A 2 2 3 1...
Страница 322: ...320 4 4 2 2 4 2 5 4 5 ET 6 6 9 FL 4 5 1 4 5 1 1 ET ET ET ET 0 ET 6 6 9 4 5 1 2 23 23...
Страница 327: ...325 15 SB F 15 SM 15 F Sb RC A SM 6 1 6 VE 6 2 2 SET MODE 6 2 1 VF 6 2 2 TE 6 2 3 BT 6 2 4 FF FF x y x y x 1 x y 64 RF...
Страница 344: ...342 FF 6 6 16 PW PW 0 PW 0 PW XXXX 10 PW 2 10 0 Mode Set PW 0 PW 2 7 3 6 6 16 1 PW PW PW PW 0 PW 0 0 PW PW PW PW PW 0 PW...
Страница 359: ...NEDERLANDS 357 Afbeelding 2 Bevestiging en minimumafstand voor luchtrecirculatie...
Страница 418: ...SVENSKA 416 Fig 2 Fasts ttning och min utrymme f r luftcirkulation...
Страница 473: ...T RK E 471 ekil 2 Hava sirk lasyonu tesisat ve minimum a kl k...
Страница 523: ...520 IEC 364 inverter...
Страница 524: ...521 1 Inverter inverter inverter 6 inverter 1 1...
Страница 528: ...525 1 2 1 1 inverter inverter 1 1 2 5 inverter 2 1 inverter 2 1 2 2 C...
Страница 529: ...526 2...
Страница 530: ...527 2 2 3 3 inverter 15 inverter 2 2 1 inverter inverter 4 2 2 1 1 PWM 203 202 201 inverter 3 1 LN 4 inverter 2...
Страница 534: ...531 6 2 2 3 3 Press Flow 7 A B C D...
Страница 539: ...536 DC V AC 50 60 Hz Vrms V 8 6 V 2 1 5 V 36 36 12V mA 3 3 3 3 mm 2 13 7 11 8...
Страница 540: ...537 11 J5 pin Pin I1 11 17 16 18 16 17 I2 11 15 16 18 15 16 I3 11 14 13 18 13 14 I4 11 12 13 8 12 13 8...
Страница 542: ...539 9 3 EEprom SET 6 SET MODE 3 1 11 3 2 1 2 3 2 1 MODE SET Setpoint MODE 10 ONOMA TOY MENOY 2 Setpoint 2 5 5 5...
Страница 545: ...542 14 3 3 go Hz bar psi 12 GO SB BL LP HP EC OC OF SC OT...
Страница 588: ...ROM N 585 Figura 2 Fixarea i distan a minim pentru circula ia aerului...
Страница 635: ...01 20 cod 60198807...