DAB PUMPS ACTIVE DRIVER M/M 1.1 Скачать руководство пользователя страница 10

ENGLISH

44

8.2

OPERATION: KEYBOARD FACTORY SETTINGS
                                                                                                                (ref. Table no. 14 page 53)

MODE 

The

MODE 

key allows you to move on to the next items in the individual menus. 

SET

The

SET

 key allows you to quit the current menu and return to normal operating status. 

+

Press to increase the currently modifiable parameter. 
Each time it is pressed, the value of the parameter is displayed for at least 6 seconds, after which the 
identifying symbol appears. 

Press to decrease the currently modifiable parameter. 
Each time it is pressed, the value of the parameter is displayed for at least 6 seconds, after which the 
identifying symbol appears. 

When the + key or the – key is pressed, the selected value is modified and saved immediately. Even the 
accidental shut-down of the machine during this phase does not cause the loss of the newly set parameter. The 

SET

 key is used only to return to the display of the machine status. It is not fundamental to press the 

SET

 key 

in order to save the changes made. 

8.3

FIRST SWITCH-ON OPERATIONS (only with ACTIVE DRIVER as accessory) 

                                                                                                              (ref. Table no. 14 page 53)

After having correctly carried out the installation of the hydraulic and electric system, power can be 
supplied to the ACTIVE DRIVER. 
The letters “ZF” will appear on the display and after a few seconds the error condition “EC” will be 
shown.
To start the ACTIVE DRIVER it is necessary to set the current value shown on the data plate (in A) and 
the frequency (in Hz) of the electropump used. 
Below are described some steps for setting the main parameters and making the first start-up.

8.3.1  Setting the rated current “rC” 

In normal operating status, hold down simultaneously the MODE and SET and - keys until "rC" appears on 
the display.
Using the + and – keys you can respectively increase and decrease the value of the parameter, according to the 
indications on the data plate of the electropump motor. 
If the set parameter is lower than the correct one, during operation the error message “oC” will appear as soon 
as the set current has been exceeded for a certain time.
If the set parameter is higher than the correct one, the overload protection will trip incorrectly beyond the 
motor safety threshold.

An incorrect configuration of the electric motor of the electropump may cause damage to the 
motor.

If SET is pressed to leave the menu without setting “Fn”, the set current value is activated but 
the ACTIVE DRIVER is not unblocked because the frequency has not been set and the letters 
“EC” will still be displayed. 

8.3.2  Setting the rated frequency “Fn” 

From the parameter “rC”, press the 

MODE

 key once, the electropump rated frequency “Fn” will appear 

on the display.
The  frequency “Fn” must be set as shown on the data plate of the electropump using the + and – keys.
The next time 

MODE

 or 

SET

 is pressed, the set current and frequency values are activated and the 

ACTIVE DRIVER is unblocked, unless other error or blocking conditions have occurred.

An incorrect configuration of the working frequency of the electropump may cause damage to 
the electropump.

8.3.3  Setting the direction of rotation 

From the parameter “Fn” press the 

MODE

 key to make the current and frequency settings active and 

move on to the next item “rt”. At this point the ACTIVE DRIVER is ready to start.
Switch on a user to start the electropump turning.
If the direction of rotation is correct, proceed to set the Setpoint pressure, otherwise invert the direction of 
rotation of the motor using the + and – keys (function active even with the motor switched on).

8.3.4  Setting the setpoint pressure 

In normal operating status, hold down simultaneously the 

MODE

 and 

SET

keys until "SP" appears on the 

display. In these conditions the + and – keys respectively allow you to increase and decrease the desired 
pressure value.
The regulating range is from 1 to 15 bar depending on the ACTIVE DRIVER model. 
Press

SET

 to return to normal operating status.

Содержание ACTIVE DRIVER M/M 1.1

Страница 1: ...ifications KONFORMIT TSERKL RUNG Die Firma DAB PUMPS s p a Via M Polo 14 Mestrino PD ITALIEN erkl rt eigenverantwortlich dass die vorstehend beschriebenen Produkte den folgenden Richtlinien entspreche...

Страница 2: ...SENIE O ZHODE Spolo nos DAB PUMPS s p a Via M Polo 14 Mestrino PD Taliansko vyhlasuje na vlastn v hradn zodpovednos e v robky uveden v d al om texte zodpovedaj Smernici Elektromagnetick kompatibilita...

Страница 3: ...nd SET and keys for 5 seconds 46 8 6 1 tb Setting the reaction time of the water lack blockage 46 8 6 2 GP Setting the gain of the proportional coefficient of the PI 46 8 6 3 GI Setting the gain of th...

Страница 4: ...ircuit between the phases of the output terminal 52 13 6 Manual reset of error conditions 52 13 7 Self reset of error conditions 52 14 INDICATIONS ON THE DISPLAY 53 INDEX OF TABLES Page Table 4 Techni...

Страница 5: ...Manufacturer declines all responsibility for possible errors in this instructions manual if due to misprints or errors in copying The Manufacturer reserves the right to make any modifications to produ...

Страница 6: ...rth terminal 5 2 Check that all the connecting cables are in excellent conditions with the external sheathing unbroken 5 3 The motor of the installed electropump must comply with the data in the table...

Страница 7: ...is operative it is absolutely necessary to protect it suitably against frost and to leave it constantly fed If it is disconnected from the power supply the anti frost function is no longer active If t...

Страница 8: ...excluding A D M M 1 1 and A D M T 1 0 250 Vac 6 A max resistive load 3 A max inductive load J14 o2 Pump operating connection terminal excluding A D M M 1 1 and A D M T 1 0 250 Vac 6 A max resistive l...

Страница 9: ...regulating pressure becomes P1 switch over active setpoint SP or P1 Example Use IN 3 When IN 3 is activated the pump is blocked and the signal F3 is given ex IN 3 could be connected to a safety pressu...

Страница 10: ...a plate of the electropump motor If the set parameter is lower than the correct one during operation the error message oC will appear as soon as the set current has been exceeded for a certain time If...

Страница 11: ...ng status 8 5 1 rC Setting the rated current of the electropump excluding A D M M 1 1 This parameter must be set the same as the current on the motor data plate Amps in the configuration in which it i...

Страница 12: ...CTIVE DRIVER on each of the two machines 8 5 7 Eb Enable booster pre set value 2 excluding A D M M 1 1 When two ACTIVE DRIVER units are interconnected with each other in the case where only one ACTIVE...

Страница 13: ...with Fn whenever a new Fn is set 8 6 6 Ft Setting the low flow rate threshold The ACTIVE DRIVER system possesses a flow sensor Whenever the electropump is switched off a new zero is acquired The ACTI...

Страница 14: ...ump has to be started for the time St The pre set value is 45 Hz and it may be varied between Fn and Fn 50 using the and keys If a FL higher than Fn 50 has been set SF will be limited to the value of...

Страница 15: ...le no 14 page 53 Access keys SET and for 2 seconds From normal operating status pressing the key SET and enters the MONITOR function where the following values are displayed NB to scroll through the v...

Страница 16: ...nks quickly When the electropump is OFF the display blinks slowly In manual mode pressing the SET key takes you out of the menu but if the electropump has been started pressing the key stops only the...

Страница 17: ...ion Description bL Blockage due to water lack bP Blockage due to absence of pressure sensor LP Blockage due to low supply voltage HP Blockage due to high rectified voltage ot Blockage due to overheati...

Страница 18: ...enever a short circuit occurs an event counter is increased and saved in the permanent memory EEPROM AFTER THE HUNDREDTH SHORT CIRCUIT THE MACHINE BLOCKS PERMANENTLY AND IT WILL NO LONGER BE POSSIBLE...

Страница 19: ...flow rate threshold 15 15 15 15 15 CM Exchange method on sets of 2 electropumps 01 01 01 01 AE Setting the enabling of the anti block anti frost function 01 01 01 01 01 SF Setting the starting freque...

Страница 20: ...e sensor LP Blockage due to low supply voltage HP Blockage due to high supply voltage ot Blockage due to overheating of the power stages oC Blockage due to current overload in the electropump motor oF...

Страница 21: ...6 Ad A D M M 1 1 136 8 5 7 Eb booster 2 A D M M 1 1 136 8 6 MODE SET 5 136 8 6 1 tb 136 8 6 2 GP PI 136 8 6 3 GI PI 137 8 6 4 FS 137 8 6 5 FL 137 8 6 6 Ft 137 8 6 7 CM 1 A D M M 1 1 137 8 6 8 AE 137...

Страница 22: ...2 140 11 RESET MODE SET 140 12 SET 140 13 140 13 1 bL 141 13 2 bP 141 13 3 LP A D M M 1 1 A D M T 1 0 142 13 4 oF ot 45 C 142 13 5 SC 142 13 6 reset 142 13 7 142 14 143 4 130 8 1 131 8 2 134 8 6 12 IN...

Страница 23: ...9 1 2 2 1 IEC 60634 2 2 CEI 64 2 2 3 ACTIVE DRIVER 2 4 IEC 536 1 NEC U V W Active Driver M M 1 1 R S EN 60204 9 2 5 4 3 ACTIVE DRIVER ACTIVE DRIVER M T 230V ACTIVE DRIVER M M 230V ACTIVE DRIVER T T 40...

Страница 24: ...r 16 bar 16 bar 16 bar 16 bar 1 6 bar 1 9 bar 1 15 bar 1 15 bar 1 15 bar x x 22x28x18 cm 22x28x18 cm 22x28x18 cm 22x28x18 cm 22x28x18 cm 1 1 1 1 1 1 1 1 1 1 IP 55 IP 55 IP 55 IP 55 IP 55 A D M M A D M...

Страница 25: ...RIVER ACTIVE DRIVER 7 2 ACTIVE DRIVER 7 3 ACTIVE DRIVER 7 4 ACTIVE DRIVER 0 C ACTIVE DRIVER ACTIVE DRIVER 8 ACTIVE DRIVER ACTIVE DRIVER inverter M M 1 1 M T 1 0 ACTIVE DRIVER 3 2 1 2 3 2 ACTIVE DRIVER...

Страница 26: ...I3 I2 A D M M 1 1 A D M T 1 0 6 IN 1 i1 A D M M 1 1 A D M T 1 0 J22 7 0V DC GND A D M M 1 1 A D M T 1 0 o1 A D M M 1 1 A D M T 1 0 250 Vac 6 A 3 A J14 o2 A D M M 1 1 A D M T 1 0 250 Vac 6 A 3 A J9 1...

Страница 27: ...N 1 F1 IN 1 IN 2 IN 2 P1 set point SP P1 IN 3 IN 3 F3 IN 3 Max 48V Max 50Vrms Max 48V Max 50Vrms Max 48V Max 50Vrms 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 6 7 AC DC 1 2 3 4 5 6 7 AC DC 1...

Страница 28: ...MODE SET SET 6 6 SET SET 8 3 ACTIVE DRIVER 14 143 ACTIVE DRIVER ZF EC ACTIVE DRIVER Hz 8 3 1 rC MODE SET rC oC SET Fn ACTIVE DRIVER EC 8 3 2 Fn rC MODE Fn Fn MODE SET ACTIVE DRIVER 8 3 3 Fn MODE rt AC...

Страница 29: ...M 1 1 1 9 bar A D M T 1 0 1 15 bar SET ACTIVE DRIVER RP bar SP 8 5 14 143 MODE SET 5 SET MODE SET rC MODE set 8 5 1 rC A D M M 1 1 Ampere 230V A D M T 400V A D T T 8 5 2 rt A D M M 1 1 0 1 Fr MODE GO...

Страница 30: ...der ACTIVE DRIVER Ad Ad ACTIVE DRIVER Go Sb Ad ACTIVE DRIVER ACTIVE DRIVER SP setpoint rP Eb booster CM M dP P1 set point P1 2 ACTIVE DRIVER 8 5 7 Eb booster 2 A D M M 1 1 ACTIVE DRIVER ACTIVE DRIVER...

Страница 31: ...Ft ACTIVE DRIVER ACTIVE DRIVER 0 ZF Ft 8 6 7 CM 1 A D M M 1 1 ACTIVE DRIVER CM 0 ACTIVE DRIVER leader ACTIVE DRIVER booster Eb 2 Eb 1 23 leader leader booster Eb 2 leader ACTIVE DRIVER booster leader...

Страница 32: ...11 St St SF PI St 1 St 0 3 8 6 12 IN1 IN2 IN3 i1 i2 i3 A D M M 1 1 A D M T 1 0 IN1 IN2 IN3 i1 i2 i3 i1 i2 i3 0 1 3 2 3 i3 3 4 5 IN1 IN2 IN3 0 1 2 3 4 5 F1 i1 F1 IN1 Set point P1 IN1 set point P1 i2 F2...

Страница 33: ...t point SP P1 1 9 bar 8 6 14 O1 1 A D M M 1 1 A D M T 1 0 O2 2 A D M M 1 1 A D M T 1 0 OUT1 OUT2 0 1 2 3 o1 o2 9 9 1 14 143 MODE MODE Fr Hz UP bar C1 A A D M M 1 1 A D M T 1 0 UE 9 2 SET 2 SET MONITOR...

Страница 34: ...FS UP bar C1 A rt UF ZF MODE MODE 2 SET SET SET SET 10 1 rt SET 2 10 2 MODE FP SET SET SET 11 RESET 14 143 MODE SET 4 MODE SET 12 14 143 SET 2 14 143 SET EE ACTIVE DRIVER ACTIVE DRIVER RC 0 EC MODE S...

Страница 35: ...141 bL oC oF SC FS FS 20 Fr Lt LC Lb bL bP LP HP ot ob oC oF oF ot 45 C SC EC rC Fn E0 E7 0 7 F1 1 F3 3 13 1 bL setpoint bL 2 3 13 2 bP ACTIVE DRIVER bP 10...

Страница 36: ...A D M T 1 0 180V ACTIVE DRIVER 200V 13 4 oF ot 45 C oF ot 45 C 2 13 5 SC ACTIVE DRIVER U V W PUMP 10 EEPROM 13 6 RESET 13 7 ACTIVE DRIVER bL 10 6 1 24 24 30 bP 10 LP 220V 20 10 HP Ot 70 C OC 10 6 oF 1...

Страница 37: ...ar 0 5 bar Ad Eb booster 02 02 02 02 MODE SET 5 tb s 10 s 10 s 10 s 10 s 10 s GP PI 1 0 1 0 1 0 1 0 1 0 GI PI 1 0 1 0 1 0 1 0 1 0 FS Hz 50 50 50 50 50 FL Hz 0 0 0 0 0 Ft 15 15 15 15 15 CM 2 01 01 01 0...

Страница 38: ...144 14 Reset MODE SET A D M M 1 1 A D M T 1 0 A D M T 2 2 A D T T 3 0 A D T T 5 5 ZF ZF SET 2 EE EEprom bL bP LP HP ot oC oF oF ot 45 C SC EC rC Fn E0 E7 0 7 F1 1 F3 3...

Отзывы: