9
SIP Operation Manual V2.6
8 ports gateways model: 8S / 8O / 6S2O / 4S4O
Front Panel
Voice ports indicators
WAN, LAN indicators
Status indicators
P4
P3
P2
P1
Power
L4
L3
L2
P6
P8
P7
VoIP Gateway
L1
WAN
P5
Alarm
RUN
Power Indicator: Green light indicates a normal power supply.
Run Indicator: Blinking green light indicates normal operation.
Alarm Indicator: When the system starts up, the red light will blink. It also indicates the
gateway’s abnormal operation.
P1 – P8 stands for Port 1 – Port 8 (Line 1 – Line 8)
WAN stands for the WAN Port Indicator.
L1 – L4 stands for the LAN Port Indicator.
When starting up the system, the Alarm, Run, and Power indicators will light up. After
about 15 seconds, the Alarm indicator will go off, the Run indicator will blink in green, and
the Power indicator will stay green under operational conditions. If the Alarm indicator
continues to blink, it means the system is currently communicating with ISP and has yet to
obtain an IP address.
When the ethereal cable is connected, the Link indicator will light up and if data is being
transmitted over the Internet, the act indicator will blink.
Rear Panel
8S
:
P1-P8 are telephone ports (FXS) to be connected to a telephone set or PBX CO ports (PSTN ports).
8O :
P1-P8 are line ports (FXO) to be connected to a PSTN (telephone lines from a PSTN.)
6S2O :
P1-P6 are telephone ports (FXS), and P7-P8 are line ports (FXO). Before the power is connected or in the
occasion of a power failure, P1 will be relayed to P7, and P2 relayed to P8 to reach PSTN.
4S4O :
P1-P4 are telephone ports (FXS), and P5-P8 are line ports (FXO). Before the power is connected or in the
occasion of a power failure, P1 will be relayed to P5, P2 relayed to P6, P3 relayed to P7, and P4 relayed to P8 to
reach PSTN.
NOTE: Do not connect FXS ports to each other. Also, do not connect any FXS port directly to a
PSTN line or internal PBX. If any of these are done, your 4S may be damaged.
Please use the power adapter comes with VoIP gateway. If using adapters other than the one
comes with VoIP gateway, it may cause problems and will affect the warranty of the product.
Restore to factory default: (IP address, User’s. Name and Password)
(1) Pull off the power plug.
(2) Press reset (do not let go of the reset button).
(3) Plug the plug back into the socket (do not let go of the reset button).
(4) Let go of the reset button after 6 seconds. Factory settings will be restored.