D-Link DMS-1100 Series User Manual
66
Click
Edit
button to configure the Ethernet Profile settings:
Figure 4.84 – L2 Features > ERPS(G.8032) > ERPS Profile - Edit
The fields that can be configured for edit
ERPS Profile
are described below:
Item
Description
Revertive
Specifies whether to enable or disable to the original state after a
failure, for example, when the RPL was blocked.
Guard Time (10-2000)
Specifies the guard time of the R-APS function. The value is between
10 and 2000 milliseconds. The default guard time is 500 milliseconds.
Hold-Off Timer (0-10000)
Specifies the hold-off time of the R-APS function. The value is between
0 and 10000 milliseconds. The default hold-off time is 0 milliseconds.
WTR Timer (1-12)
Specifies the WTR time of the R-APS function. The value is between 1
and 12 minutes. The default WTR time is 5 minutes.
Table 4.54
Click
Apply
to make the configurations take effect.
Click the
Back
button to return to the previous page.
L2 Features > Loopback Detection
The Loopback Detection function is used to detect the loop created by a specific port while Spanning Tree
Protocol (STP) is not enabled in the network, especially when the down links are hubs or unmanaged
switches. The Switch will automatically shut down the port and send a log to the administrator. The Loopback
Detection port will be unlocked when the Loopback Detection
Recover Time
times out. The Loopback
Detection function can be implemented on a range of ports at a time. You may enable or disable this function
using the pull-down menu.
Содержание DMS-1100-10TS
Страница 1: ...User Manual DMS 1100 Series L2 2 5 Gigabit Ethernet Switch Series Rev A 1 ...
Страница 2: ......
Страница 12: ...D Link DMS 1100 Series User Manual 6 Light off No PD device insert ...
Страница 32: ...D Link DMS 1100 Series User Manual 26 Figure 4 24 User Guide Micro Site ...
Страница 116: ...110 ...