DGS-6604
m
show environment
CLI Reference Guide
604
Example
The example shows how to display the H/W environmental information.This example
includes the thermal sensor status, the operation temperature range, fan operation
speed, fan status, and power status.
Switch#show environment
Environmental Status
Slot Inlet temperature Center temperature Outlet temperature
current/operation range current/operation range current/operation range
---- ----------------------- ----------------------- ----------------------
1 35 C/0 ~75 C 35 C/0 ~75 C N/A
2 42 C/0 ~70 C 38 C/0 ~80 C 38 C/0 ~80 C
3 37 C/0 ~76 C 36 C/0 ~77 C 43 C/0 ~75 C
4 42 C/0 ~76 C 36 C/0 ~77 C 38 C/0 ~75 C
Status code: * temperature is out of operation range
Fans are operation in normal speed
Failed Fans: None
Power module #1 #2 #3 #4
--------------- ------------- ------------- ------------- -------------
Power status in-operation empty empty empty
Max power 850 W - - -
Used power 203 W - - -
Switch#show environment power
Environmental Status
Power module #1 #2 #3 #4
--------------- ------------- ------------- ------------- -------------
Power status in-operation empty empty empty
Max power 850 W - - -
Used power 203 W - - -
Switch#