background image

Appendix A - Technical Specifications

  

D-Link Smart Managed Switch User Manual

 

 

4

4

1

1

 

 

 

Appendix A - Technical Specifications 

Key Components / Performance 

Switching Capacity 

DGS-1100-05/05PD: 10 Gbps 

DGS-1100-08/08P:    16 Gbps 

Max. Forwarding Rate 

DGS-1100-05/05PD: 7.4 Mpps 
DGS-1100-08/08P:   11.9 Mpps 

Forwarding Mode 

Store and  Forward 

Packet Buffer memory 

DGS-1100-05/05PD: 1 Mb 

DGS-1100-08/08P:    1.5 Mb

 

DRAM Size 

48 KB 

Flash Memory 

2 MB 

Port Functions 

10/100/1000BASE-T 
ports 

5/8 10/100/1000Base-T ports compliant with the following standards: 

- IEEE 802.3 

    - IEEE 802.3u 

    - IEEE 802.3ab 

 

Support Half/Full-Duplex operations 

    - IEEE 802.3x Flow control support for Full-Duplex mode 

    - Back Pressure for Half-Duplex mode 

    - Head-of-line blocking prevention 

 

Support manual/auto-MDI/MDIX configuration. 

Support auto-negotiation for each port 

Physical & Environment 

Dimensions 

DGS-1100-05:      

100.5 x 82 x 28 mm 

DGS-1100-05PD: 150 x 97 x 28 mm 

DGS-1100-08:      

145 x 82 x 28 mm 

DGS-1100-08P:    171 x 97.8 x 28.6 mm

 

Weights 

DGS-1100-05:      

0.23 kg 

DGS-1100-05PD: 0.38 kg 

DGS-1100-08:      0.34 kg 

DGS-1100-08P:    0.433 kg 

Power Supply 

DGS-1100-05/08/08P: AC

100 ~ 240 V  

DGS-1100-05PD: NO external power supply, PoE input only 

Power Consumption 

DGS-1100-05:      Maximum

 – AC 3.42 W 

                             Standby – AC 1.39 W 

DGS-1100-05PD: Maximum – AC 23.922 W 

                             Standby – 1.458 W 

DGS-1100-08:     Maximum

 – AC 4.94 W 

                            Standby – AC 1.93 W 

DGS-1100-08P:   Maximum – AC 77.9 W 

                             Standby –  2.0 W 

Содержание DGS-1100-05PD

Страница 1: ...D G S 1 1 0 0 0 5 0 8 0 8 P 0 5 P D Ma n u a l S MA R TMA N A G E DS WI T C H V e r 2 1 0 ...

Страница 2: ...10 Management Options 10 Using the Web based Management Interface 10 Connecting to the Switch 10 Accessing the Web based Management Interface 10 Web based Management 11 D Link Network Assistant DNA 11 4 Configuration 12 Web based Management 12 Tool Bar Save Menu 13 Save Configuration 13 Tool Bar Tool Menu 13 Reboot System 13 Reset 13 Firmware Backup and Upgrade 13 Configuration Backup and Restore ...

Страница 3: ...metric VLAN 27 L2 Features VLAN Surveillance VLAN 27 L2 Features VLAN Voice VLAN 29 L2 Features Spanning Tree STP Global Settings 30 L2 Features Spanning Tree STP Port Settings 31 L2 Features Loopback Detection 32 L2 Features Link Aggregation 32 L2 Features L2 Multicast Control IGMP Snooping IGMP Snooping Settings 33 L2 Features L2 Multicast Control IGMP Snooping IGMP Snooping Group Settings 34 Qo...

Страница 4: ...he term Switch first letter capitalized refers to the Smart Managed Switch and switch first letter lower case refers to other Ethernet switches Some technologies refer to terms switch bridge and switching hubs interchangeably and both are commonly accepted for Ethernet switches A NOTE indicates important information that helps a better use of the device A CAUTION indicates potential property damag...

Страница 5: ...iority queues enabling users to run bandwidth sensitive applications such as streaming multimedia by prioritizing that traffic in network The Surveillance VLAN will place the video traffic from pre defined IP surveillance devices to an assigned VLAN with higher priority so it can be separated from normal data traffic Network Security Storm Control can help to keep the network from being overwhelme...

Страница 6: ... the Switch is connected to a power source If the Power LED is Blinking PoE Pass Through is Off Link Act Speed LED Ports 1 5 Flashing Indicates a network link through the corresponding port Blinking Indicates that the Switch is either sending or receiving data to the port Green Indicates that the port is running at 1000M Amber Indicates that the port is running at 10 100M Light off No link PoE PSE...

Страница 7: ...100 1000 Mbps ports to connect Ethernet devices to the switch Rear Panel Figure 1 6 DGS 1100 08 Rear Panel Power Input for a 5V 1A AC adapter Reset Press the Reset button for 1 to 5 seconds to reboot the Switch Press the Reset button for 6 to10 seconds to reset the Switch back to the default settings The LED will light up solid amber for 2 seconds When pressing the Reset button for longer than 10 ...

Страница 8: ...r Indicates that the port is running at 10 100M Light off No link PoE MAX LED Light up Indicates the power output to PDs is over 57W No additional PDs can be powered for safety consideration Blinking Indicates if the user unplugged certain PDs and made the PoE power budget left over 7W the PoE MAX LED will blink 5 seconds Light off Indicates the power budget is using less than 57W PoE LED Ports 1 ...

Страница 9: ...certain PDs and made the PoE power budget left over 7W the PoE MAX LED will blink 5 seconds Light off When the power budget is using less the 57W LED Per 10 100 1000 Mbps Port Link Act Speed Green Amber Solid Green Indicates there is a 1000 Mbps connection on this port Blinking Green Indicates data is being processed on this port at 1000 Mbps Solid Amber Indicates there is a 10 100 Mbps connection...

Страница 10: ...1 Product Introduction D Link Smart Managed Switch User Manual 7 7 Light off No link ...

Страница 11: ...vy objects on the switch Desktop or Shelf Installation The DGS 1100 series switches come with a strip of four adhesive rubber pads that can be placed on the bottom of the device to prevent the device from damaging the desktop or shelf it is places on To attach the rubber pads simply remove them from the adhesive strip and stick one pad on each corner on the bottom panel of the Switch Figure 2 1 At...

Страница 12: ...dware Installation D Link Smart Managed Switch User Manual 9 9 Step 2 Hook the mounting keyholes on the back of the Switch onto the screws to secure the device to the wall Figure 2 2 Wall mount installation ...

Страница 13: ...tructions for the Web interface and the D Link Network Assistant DNA Using the Web based Management Interface After successfully installing the Switch you can configure and monitor the Switch through the web based management tool using any compatible web browser such as Internet Explorer Google Chrome Firefox Opera or Safari Connecting to the Switch The access the web interface you will need the f...

Страница 14: ...stant DNA is a program that is used to discover switches which are in the same Layer 2 network segment as your PC You can download the DNA App from the Chrome web store and install it in a Chrome web browser 1 Go to the Chrome web store at https chrome google com webstore and search the store for Network Assistant Figure 3 4 D LINK Network Assistant 2 Click ADD TO CHROME button on the right hand s...

Страница 15: ...d basic settings Clicking on a section or subsection in the function tree will display all the settings of that section in the main configuration screen The main configuration screen will show the current status of your Switch by clicking the model name on top of the function tree In the upper right corner of the screen the username and current IP address will be displayed Under the username is th...

Страница 16: ...des a safe way to reboot the system Click Yes or No to decide to save the settings does this really reset to factory default settings or does it just discard the most recent unsaved changes Click Reboot to restart the switch Figure 4 5 Tool Menu Reboot System Reset Provide a safe reset option for the Switch Depending on the chosen reset option some or all configuration settings stored in the devic...

Страница 17: ...configuration settings from this file Figure 4 9 Tool Menu Configure Backup and Restore Backup current settings to file Specify to back up the current settings of the Swtich with or without the password and click Backup Restore saved settings from file Click Choose File to browse your inventories for a saved backup settings file And click Restore to backup settings file you want to restore Note Sw...

Страница 18: ...Settings System Information The System Information allows the user to configure the basic system information of the Switch By entering the system information the device can more easily be recognized from other Smart Managed devices on the network Figure 4 13 System System Information Settings System Information The fields that can be configured for System Information are described below Item Descr...

Страница 19: ...escribed below Item Description IP Settings There are two ways for the Switch to obtain an IP address Static and DHCP Dynamic Host Configuration Protocol When using static mode the IP Address Mask Gateway and DHCP Retry Time can be manually configured When using DHCP mode the Switch will first look for a DHCP server to provide it with an IP address including network mask and default gateway before...

Страница 20: ...Description Specify a description for the chosen ports Capability Advertised When the Speed is set to Auto these capabilities are advertised during auto negotiation Table 4 3 Click Apply to make the configurations take effect Click Refresh button to update the port status information NOTE Be sure to adjust port speed settings appropriately after changing the connected cable media types System Port...

Страница 21: ... Status Total PoE Power Budget Displays the total PoE power budget of this switch Power Used Displays the current used power of the switch Power Left Displays the spare power of the switch The percentage of system supplied Displays the percentage of system power supplied of the switch Table 4 4 Click Apply to make the configurations take effect System PoE PoE Configuration DGS 1100 05PD 08P only T...

Страница 22: ...ion of a port or ports State Select enable or disable to configure PoE function for designated port s Default is Enabled Priority Configure the power supply priority as Low Normal or High on designated port s Default is Normal Legacy Support Specify to enable or disable detecting legacy PDs signal Power Limit This function allows you to manually set the port power current limitation to be given to...

Страница 23: ...anagement Password Access Control The fields that can be configured for Password Access Control are described below Item Description Old Password Enter the old password of the Switch New Password Enter the new password of the Switch Confirm Password Enter the new password of the Switch again Table 4 6 Click Apply to make the configurations take effect Management SNMP SNMP Global Settings Simple Ne...

Страница 24: ...to the management station Coldstart Check this feature to have client devices send an SNMP notification to the management station when performing a cold start Warmstart Check this feature to have client devices send an SNMP notification to the management station when performing a warm start Table 4 7 Click Apply to make the configurations take effect Management SNMP SNMP Community Table Settings T...

Страница 25: ...Specify the community string for the management host Table 4 9 Click Apply to make the configurations take effect Management D Link Discovery Protocol For devices that support the D Link Discovery Protocol DDP this page allows users to enable or disable DDP and configure the DDP packet report timer Figure 4 23 Management D Link Discovery Protocol The fields that can be configured for D Link Discov...

Страница 26: ... FDB page allows user to view and configure the static multicast forwarding settings on the Switch Figure 4 25 L2 Features FDB Static FDB Multicast Static FDB The fields that can be configured for Multicast Static FDB are described below Item Description From Port To Port Enter the appropriate port range used for the configuration VID Enter the VLAN ID of the VLAN the corresponding MAC address bel...

Страница 27: ...ription Port Select a single port or all ports The information for the port s will be displayed in the information table Table 4 14 Click Find to locate a specific entry based on the information entered Click Select All to select all dynamic MAC addresses Click Clear All to clear all dynamic MAC addresses NOTE When viewing the different FDB pages the device will take a moment to refresh the UI L2 ...

Страница 28: ... VID Enter the VID to be created VLAN Name Enter the VLAN name for the VID to be created Port Assign ports as Untag Tag or Not Member Click All to select all ports Table 4 15 Click Apply to create a new VID group To configure the PVID settings click PVID Settings and the following will be displayed Figure 4 30 L2 Features VLAN 802 1Q VLAN PVID Settings Click Apply to make the configurations take e...

Страница 29: ...VLAN group click Add VLAN and the following will be displayed Figure 4 33 L2 Features VLAN Port Based VLAN Enabled Enter the VLAN Name and select the Member port to be created Click Apply to make the configurations take effect Click Cancel to discard any changed made and return to the previous page L2 Features VLAN Management VLAN The 802 1Q Management VLAN setting allows user to transfer manageme...

Страница 30: ...N Asymmetric VLAN The fields that can be configured for Asymmetric VLAN are described below Item Description Asymmetric VLAN State Specify to enable or disable the Asymmetric VLAN of the Switch The default value is disabled Table 4 17 Click Apply to make the configurations take effect L2 Features VLAN Surveillance VLAN Surveillance VLAN is a feature that allows you to place the video traffic from ...

Страница 31: ... Specify the priority level The levels of priority are High Medium and Low The default priority is High User defined MAC Settings Component Type Surveillance VLAN will automatically detect D Link surveillance devices by default There are another five surveillance components that can be configured for surveillance VLAN These five components are Video Management Server VMS VMS Client Video Encoder N...

Страница 32: ... Settings Voice VLAN Specify to enable or disable the Voice VLAN function VLAN ID Specify the VLAN ID to act as a Voice VLAN Priority Specify the priority level The levels of priority are High Medium and Low The default priority is High OUI Settings Default OUI Pre defined Organizationally Unique Identifier OUI values including 3COM Cisco Veritel Pingtel Siemens NEC Phillips Huawei3COM and Avaya U...

Страница 33: ...en if a BPDU packet is not received Therefore each connection between bridges is sensitive to the status of the link Ultimately this difference results in faster detection of failed links and therefore faster topology adjustment Figure 4 38 L2 Features Spanning Tree STP Global Settings The fields that can be configured are described below Item Description Spanning Tree State Spanning Tree State Se...

Страница 34: ...STP Group Figure 4 39 L2 Features Spanning Tree STP Port Settings The fields that can be configured are described below Item Description From Port To Port Select the range of ports to be included in the spanning tree port group Port Fast Select the Port Fast option here Options to choose from are Network Disabled and Edge In the Network mode the port will remain in the non port fast state for thre...

Страница 35: ... to enable or disable loopback detection function The default is Disabled Time Interval 1 32767 Set a Loop detection Interval between 1 and 32767 seconds The default is 10 seconds Recover Time 0 or 60 1000000 Time allowed in seconds for recovery when a Loopback is detected The Loop Detection Recover Time can be set at 0 seconds or 60 to 1000000 seconds Entering 0 will disable the Loop Detection Re...

Страница 36: ... 1 Link Aggregation group and DGS 1100 08 supports up to 2 Link Aggregation groups NOTE Each combined port must be connected to devices within the same VLAN group L2 Features L2 Multicast Control IGMP Snooping IGMP Snooping Settings With Internet Group Management Protocol IGMP snooping the Smart Managed Switch can make intelligent multicast forwarding decisions by examining the contents of each fr...

Страница 37: ...e IGMP Snooping group Table 4 26 Click Add to create a new IGMP Snooping group Click Delete to remove the corresponding IGMP Snooping group Click Delete All to remove all IGMP Snooping groups Click Refresh to renew the IGMP Snooping Groups Table information QoS 802 1p DSCP Default Priority Quality of Service QoS is an implementation of the IEEE 802 1p standard that allows network administrators to...

Страница 38: ... a Strict scheduling will set the highest queue to be emptied first while the other queues will follow the weighted round robin scheduling scheme WRR Use the weighted round robin WRR algorithm to handle packets in an even distribution among priority classes IEEE 802 1p Default Priority Settings From Port To Port Specify a range of ports to be configured Priority Defines the priority level for the ...

Страница 39: ... a group of ports on a single Switch This method of segmenting the flow of traffic is similar to using VLANs to limit traffic but is more restrictive Figure 4 46 Security Traffic Segmentation The fields that can be configured for Traffic Segmentation Settings are described below Item Description From Port To Port Specify a range of ports to be configured as sources ports From Forward Port To Forwa...

Страница 40: ... locked to prevent users from modifying the MAC address forwarding table Locking ports also prevents additional MAC addresses from being learned Figure 4 48 Security Port Security The fields that can be configured for Port Security are described below Item Description From Port To Port Specify a range of ports to be configured Admin State Select Enable to lock down the port and the associated MAC ...

Страница 41: ...he Ethernet cable Open in Cable means the wires of RJ45 cable may be broken or the other end of the cable is simply disconnected Test Failed means and error occurred during the cable test Please select the same port and test again Cable Fault Distance meters Indicates the distance of the cable fault from the Switch port If the cable is less than 2 meters it will show No Cable whether the cable is ...

Страница 42: ...t is received on the source port s and forwards it to the Target Port Click all to include all ports into port mirroring Tx Duplicates the data transmitted from the source port and forwards it to the Target Port Click all to include all ports into port mirroring Both Duplicate both the data transmitted from and data sent to the source port s and forwards all the data to the assigned Target Port So...

Страница 43: ...lded twisted pair UTP cabling a flexible foundation for the next generation of network technology products will be created This will outfit your network with a powerful 1000 Mbps capable backbone server connection Fast Ethernet Technology The growing importance of LANs and the increasing complexity of desktop computing applications are fueling the need for high performance networks A number of hig...

Страница 44: ...l Duplex operations IEEE 802 3x Flow control support for Full Duplex mode Back Pressure for Half Duplex mode Head of line blocking prevention Support manual auto MDI MDIX configuration Support auto negotiation for each port Physical Environment Dimensions DGS 1100 05 100 5 x 82 x 28 mm DGS 1100 05PD 150 x 97 x 28 mm DGS 1100 08 145 x 82 x 28 mm DGS 1100 08P 171 x 97 8 x 28 6 mm Weights DGS 1100 05...

Страница 45: ...D Link Smart Managed Switch User Manual 42 Operation Temperature 0 40 C Storage Temperature 40 70 C Operation Humidity 0 90 RH Storage Humidity 0 95 RH EMI Certifications CE FCC ITE RCM VCCI BSMI CCC Safety Certifications cUL CB CCC BSMI ...

Страница 46: ...t accept any interference received including interference that may cause undesired operation Innovation Science and Economic Development Canada ISED Statement This Class B digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la classe B est conforme à la norme NMB 003 du Canada Japan Voluntary Control Council for Interference Statement この装置は クラス B 情報技術装置です この装置は 家庭環境で使用することを...

Страница 47: ... statique de votre corps en touchant un objet en métal relié à la terre par exemple avant de toucher le produit N essayez pas d intervenir sur le produit et ne le démontez jamais Pour certains produits contenant une batterie remplaçable par l utilisateur veuillez lire et suivre les consignes contenues dans le manuel d utilisation Ne renversez pas d aliments ou de liquide sur le produit et n insére...

Страница 48: ...tras fuentes de calor Desenchufe siempre el producto de la alimentación de red antes de limpiarlo y utilice solo un paño seco sin pelusa VEILIGHEIDSINFORMATIE De volgende algemene veiligheidsinformatie werd verstrekt om uw eigen persoonlijke veiligheid te waarborgen en uw product te beschermen tegen mogelijke schade Denk eraan om de gebruikersinstructies van het product te raadplegen voor meer inf...

Страница 49: ...E Dieses Symbol auf dem Produkt oder der Verpackung weist darauf hin dass dieses Produkt gemäß bestehender örtlicher Gesetze und Vorschriften nicht über den normalen Hausmüll entsorgt werden sollte sondern einer Wiederverwertung zuzuführen ist Bringen Sie es bitte zu einer von Ihrer Kommunalbehörde entsprechend amtlich ausgewiesenen Sammelstelle sobald das Produkt das Ende seiner Nutzungsdauer err...

Страница 50: ... ha llegado al fin de su vida útil algunos de ellos aceptan recogerlos de forma gratuita Al reciclar el producto y su embalaje de esta forma contribuye a preservar el medio ambiente y a proteger la salud de los seres humanos D Link y el medio ambiente En D Link comprendemos y estamos comprometidos con la reducción del impacto que puedan tener nuestras actividades y nuestros productos en el medio a...

Страница 51: ...e schakelen of uit de stekker te halen wanneer u ze niet gebruikt Door dit te doen bespaart u energie en beperkt u de CO2 emissies Breng een bezoek aan www dlinkgreen com voor meer informatie over onze milieuverantwoorde producten en verpakkingen POLSKI PL Ten symbol umieszczony na produkcie lub opakowaniu oznacza że zgodnie z miejscowym prawem i lokalnymi przepisami niniejszego produktu nie wolno...

Страница 52: ...ete na adrese www dlinkgreen com MAGYAR HU Ez a szimbólum a terméken vagy a csomagoláson azt jelenti hogy a helyi törvényeknek és szabályoknak megfelelően ez a termék nem semmisíthető meg a háztartási hulladékkal együtt hanem újrahasznosításra kell küldeni Kérjük hogy a termék élettartamának elteltét követően vigye azt a helyi hatóság által kijelölt gyűjtőhelyre A termékek egyes helyeken ingyen el...

Страница 53: ...ikke må bortskaffes som husholdningsaffald mens skal sendes til genbrug Indlever produktet til et indsamlingssted som angivet af de lokale myndigheder når det er nået til slutningen af dets levetid I nogle tilfælde vil produktet blive modtaget gratis Ved at indlevere produktet og dets emballage til genbrug på denne måde bidrager du til at beskytte miljøet og den menneskelige sundhed D Link og milj...

Страница 54: ...rmar och bygger D Link sina produkter för att de ska vara så miljövänliga som möjligt genom att använda återvinningsbara material med låg gifthalt i både produkter och förpackningar D Link rekommenderar att du alltid stänger av eller kopplar ur dina D Link produkter när du inte använder dem Genom att göra detta hjälper du till att spara energi och minska utsläpp av koldioxid För mer information om...

Страница 55: ......