Connection / Raccordement  / Conexión 

2 drives star-shaped / 2 moteurs en étoile /
2 accionamientos en estrella 

Mot. a

Mot. b

1

2

3

4

5

L

6

N–

7

Z

A E/X

a

b

LT

Group / Groupe / Grupo

MOT

(BK)

(BK)

(OG)

2x47k

W

Endmodul

Terminal module

Module terminal

EM 47 K *

(WH)

(WH)

(BN)

(BN)

(OG)

(OG)

(YE)

(YE)

(GN)

(GN)

(GY)

(GY)

Mot. a

Mot. a

Mot. b

Mot. b

ACB.a/HS

ACB.a/HS

BSY+.a

BSY+.a

BSY+.b

BSY+.b

ACB.b

ACB.b

CDC-0252-1

CDC-0252-1

****

***

**

Junction box /
Boîte de dérivation /
Caja de conexión 

?

**

Master 2

Slave 1

**

**

High-Speed

High-Speed

High-Speed

***

(WH) 

white 

/  blanc  

/  blanco

(BN) 

brown 

/  brun  

/  marrón

(OG) 

orange 

/  orange 

/  naranja

(YE) 

yellow 

/  jaune 

/  amarillo

(GN) 

green 

/  vert  

/  verde

(PK) 

pink 

/  rose  

/  rosa

(GY) 

grey 

/  gris  

/  gris

Monitoring /

Supervision /

Supervisión *

Not in case of / Pas pour / No en el caso : GVL -E/ -K/ -M

** 

Protect wire against short circuit / Protéger contre les courts-circuits / Proteger contra cortacircuitos

*** 

In case of connection to D+H SHEV control panels with E/HS line monitoring /

 

En cas de raccordement à des centrales D+H RWA, avec une surveillance des lignes E/HS /

 

En caso de conexión con paneles de control D+H SHEV con control de líneas E/HS 

****  Cable according to D+H table for layout of cables (See instructions for use of control panel) /
 

Câble selon le tableau de câblage de D+H (voire fiche technique de la centrale) /

 

Cable conforme a la tabla de cableado D+H (véanse instrucciones de uso de la central)

Mot. b 

(BN)

 Mot. a 

(WH)

24 V DC

24 V DC

Normal mode
Activité normale
Servicio normal

SHEV- fast running
EFC fonctionnement rapide
marcha rápida SVHC

Connection / Raccordement  / Conexión 

Mot. a

Mot. b

1

2

3

4

5

L

6

N–

7

Z

A E/X

a

b

LT

Group / Groupe / Grupo

MOT

(BK)

(BK)

(OG)

2x47k

W

Endmodul

Terminal module

Module terminal

EM 47 K *

(WH)

(BN)

(OG)

(YE)

(GN)

(GY)

Mot. a

Mot. b

ACB.a/HS

BSY+.a

BSY+.b

ACB.b

CDC-0252-1

****

***

**

**

**

Junction box /
Boîte de dérivation /
Caja de conexión 

?

**

Master 1

High-Speed

High-Speed

High-Speed

***

Mot. a

Mot. b

1

2

3

4

5

L

6

N–

7

Z

A E/X

a

b

LT

Group / Groupe / Grupo

MOT

(BK)

(BK)

(OG)

2x47k

W

Endmodul

Terminal module

Module terminal

EM 47 K *

(WH)

(BN)

(OG)

(YE)

(GN)

(GY)

Mot. a

Mot. b

ACB.a/HS

BSY+.a

BSY+.b

ACB.b

CDC-0252-1

****

***

**

**

**

Junction box /
Boîte de dérivation /
Caja de conexión 

?

**

Master 2

2 up to max. 3 drives looped through /
2 jusqu'au plus 3 moteurs par bouclage  /
2 hasta un máximo de 3 accionamientos en bucle 

(WH)

(BN)

(OG)

(YE)

(GN)

(GY)

Mot. a

Mot. b

ACB.a/HS

BSY+.a

BSY+.b

ACB.b

CDC-0252-1

Slave 1

Mot. b 

(BN)

 Mot. a 

(WH)

24 V DC

24 V DC

Monitoring /

Supervision /

Supervisión *

Monitoring /

Supervision /

Supervisión *

Normal mode
Activité normale
Servicio normal

SHEV- fast running
EFC fonctionnement rapide
marcha rápida SVHC

1 drive /
1 moteur /
1 accionamiento

Содержание CDC-0252-1-ACB

Страница 1: ...por separado Standard version R Ex cution standard R Est ndar modelo R Mirrored version option L Ex cution invers e option L Versi n invertida Opci n L en Original instructions Page 2 Connection Page...

Страница 2: ...after closing Direct connection of additional closing edge protection at the drive possible SKS option WARNING Read all safety warnings instructions illustrations and specifications provided with this...

Страница 3: ...lity Ambient humidity Emission sound pressure level Additional functions approx 1500 N without console 10 000 double strokes 30 S6 EN 60034 1 Aluminium powdercoated RAL 9006 IP 32 15 75 C 30 min 300 C...

Страница 4: ...ng stroke and drive errors are transmitted to the control panel BSY synchronised electronics A synchronous group can contain up to 8 drives which communicate via bus Each drive has its own address con...

Страница 5: ...nly applies in the ex factory configuration As soon as the drives are reconfigured with SCS the ex factory addressing no longer applies Wiring Is the drive or drive group wired properly See connection...

Страница 6: ...nd cleaning Maintenance work is only allowed when the device is in a de energized condition Inspection and maintenance has to be carried out according to D H maintenance notes Only original D H spare...

Страница 7: ...ns Tenirlespersonnes l cartdelazone demouvementdelamotorisation Tenirlesenfants l cartdelacommande Respecterlediagrammedechargedepression delacha ne N utiliserquedansdeslocauxsecs Uniquementpourmontag...

Страница 8: ...pure En peu de temps C3 250 mm 250 N Plages d ouverture et de fermeture O1 C1 C2 O2 O3 23 mm 150 N 77 mm 150 N 23 mm 250 N 15 mm 250 N 250 N Type CDC 0252 0350 1 ACB CDC 0252 0500 1 ACB CDC 0252 0600...

Страница 9: ...pe de synchronisation peut se composer de maximum 8 moteurs qui communiquent par le biais d un bus Chaque moteur poss de sa propre adresse laquelleestconfigurable l aidedulogicielSCS Le dernier moteur...

Страница 10: ...l tat la livraison En effet en cas de reconfiguration avec le logiciel SCS l adressage d fini en usine n est plus valable C blage Le moteur ou le groupe de moteurs est il correctement c bl Voir plans...

Страница 11: ...vice avait t entrepris e par un partenaire de service et de vente D H autoris Si vous raccordez les composants D H des installations trang res ou panachez les produits D H des pi ces d autres construc...

Страница 12: ...ficharojadeseguridadadjunta 5 Peligrodeatrapamientoconfuertepresi nenlas reasaccesiblesconlasmanos 6 Los operadores de las ventanas han sido evaluados nicamente para su uso residencial o para el uso c...

Страница 13: ...ca de emisi n Funciones adicionales aprox 1500 N sin fijaci n 10 000 dobles carreras 30 S6 EN 60034 1 Aluminio Pintura en polvo RAL 9006 IP 32 15 75 C 30 min 300 C 90 sin condensaci n LpA 35 dB A Acti...

Страница 14: ...nizaci n Un grupo sincronizado puede estar formado por un total de hasta 8 motores que se comunican a trav s de un bus Cada motor tiene su propia direcci n la cual puede configurarse mediante el softw...

Страница 15: ...e vuelvan a configurar los motores con el software SCS las direcciones de f brica ya no ser n aplicables Cableado Se ha realizado correctamente el cableado del accionamiento o del grupo de accionamien...

Страница 16: ...echadelaentrega siemprequeelmontaje y la puesta en marcha hayan sido realizados por un distributor autorizado de D H La garant a de D H expira en el caso de conexi n de componentes de D H con otros eq...

Страница 17: ...erde PK pink rose rosa GY grey gris Option SKS Opci n SKS BN Mot b OG SKS GY SKS GN BSY b YE BSY a WH Mot a BN Mot b OG ACB a HS GY ACB b GN BSY b YE BSY a WH Mot a Option SA SZ Opci n SA SZ BN Mot b...

Страница 18: ...MOT BK BK OG 2x47kW End mod ul Term inal mod ule Mod ule term inal EM 47 K WH BN OG YE GN GY Mot a Mot b ACB a HS BSY a BSY b ACB b CDC 0252 1 Junction box Bo te de d rivation Caja de conexi n Master...

Страница 19: ...k rose rosa GY grey gris gris Monitoring Supervision Supervisi n Not in case of Pas pour No en el caso GVL E K M Protect wire against short circuit Prot ger contre les courts circuits Proteger contra...

Страница 20: ...mersbek Rights to technical modifications reserved Sous r serve de modifications techniques Derecho reservado a modificaciones t cnicas 100 Recycled paper Papier recycl Papel reciclado B C 30 mm 3 5 m...

Отзывы: