TITLE
OPERATOR MANUAL
PAGE
PRINTERS
ARTRIX H8
7
VERSION
2017SEP01/1
OUT OF
REVISED BY
MUNOZ, ANTONIO
77
FOR THE USER
d·gen, Inc. - COMPANY PRIVATE (LEVEL 1)
NOT TO BE DISCLOSED TO UNAUTHORIZED PERSONS – PROHIBIDA SU DIVULGACIÓN A PERSONAS NO AUTORIZADAS
DO NOT REPRODUCE WITHOUT AUTHORIZATION – NO REPRODUCIR SIN AUTORIZACIÓN
5
Inductive motor and reducer.
To turn the brush roller when cleaning the conveyor. To be serviced only by a d∙gen qualified
technician.
6
Electric cabinet.
Equipped with high voltage electric components such us breakers, servo driver units and inverters.
To be serviced only by a d∙gen qualified technician.
7
Emergency push switch button.
This printer has a total of 4 emergency buttons. 2 more at the back side.
CARRIAGE
1
Solenoid valves.
The solenoid valve is opened if the LED is turned on. Having the solenoid valve opened allows free
circulation of negative air pressure between the vacuum pump and the head. Making the heads to
bleed for long purging is possible by closing the solenoid valve (LED switched off) right after the purge
button is pressed in the touch panel.
2
Emergency laser sensor.
Designed to bring the machine into an emergency stop when intercepting the beam between the 2
sensors.
3
Touch Operating Panel.
Running on version 8. The manual comes separately.
4
Print head service hoses.
Use the provided syringe to suck out the air in the print heads. Never use the syringe to flush the
print heads. Risk of voiding the warranty.
Содержание Artrix H8
Страница 1: ...OPERATOR MANUAL ...