Cajas acústicas activas / Self-powered loudspeaker enclosures

line array

Para 

EVENT-26A

, la altura máxima de seguridad desde el suelo a 

la base de la caja montada sobre trípode modelo 

TRD-2

 (necesita 

además 

AXS-EV26

), con pies a 55 cm del eje del trípode, es:

For 

EVENT-26A

, the maximum safety height from floor to bottom 

of enclosure when mounting on a 

TRD-2

 tripod (it needs also 

AXS-EV26

), with legs spread 55cm from the central pole, is:

55 cm

 

1x 

EVENT-26A 

------------->142 cm

 

2x 

EVENT-26A 

------------->132 cm

 

1x 

EVENT-26A 

------------->142 cm

 

2x 

EVENT-26A 

------------->132 cm

The exclamation point inside an equilateral triangle is intended to 
alert  the  users  to  the  presence  of  important  operating  and 
maintenance  (servicing)  instructions  in  the  literature 
accompanying  the  product.  Heed  all  warnings.  Follow  all 
instructions. Keep these instructions.
WARNING: This is a class A product. In a domestic environment 
this product may cause radio interferences in which case the 
user may be required to take adequate measures.
Use  this  product  only  in  E1,  E2,  E3  or  E4  environments 
according to EN55103-2.

Para  desconectar  el  dispositivo  debe  usar  el  enchufe. 
Desconecte  este  aparato  durante  tormentas  eléctricas, 
terremotos  o  cuando  no  se  vaya  a  emplear  durante  largos 
periodos.

To disconnect the device, you should use the mains plug. Unplug 
this  apparatus  during  lightning  storms,  earthquakes  or  when 
unused for long periods of time.

Equipo  diseñado  para  funcionar  entre 15ºC  y 45ºC  con una 
humedad relativa máxima del 95%, con un rango de ±10% de la 
tensión nominal de alimentación indicada en la etiqueta trasera. 
Si debe sustituir el fusible preste atención al tipo y rango.

Working temperature ranges from 15ºC to 45ºC with a relative 
humidity of 95%, with ±10% of the rated main voltage value 
indicated on the rear label. If the fuse needs to be replaced, 
please pay attention to correct type and ratings.

No instale el aparato cerca de ninguna fuente de calor como 
radiadores, estufas u otros aparatos que produzcan calor. Debe 
instalarse siempre sin bloquear la libre circulación de aire por las 
aletas del radiador.

Do not install near any heat sources such as radiators, heat 
registers,  stoves  or  other  apparatus  that  produce  heat.  The 
circulation of air through the heatsink must not be blocked.

No exponga este equipo a la lluvia o humedad. No use este 
aparato cerca del agua (piscinas y fuentes, por ejemplo). No 
exponga el equipo a salpicaduras ni coloque sobre él objetos 
que contengan líquidos, tales como vasos y botellas.
Equipo IP-43.

Do not expose this device to rain or moisture. Do not use this 
apparatus  near  water  (for  example,  swimming  pools  and 
fountains). Do not place any objects containing liquids, such as 
bottles or glasses, on the top of the unit. Do not splash liquids 
on the unit. IP-43 equipment.

No  emplace  altavoces  en  proximidad  a  equipos  sensibles  a 
campos  magnéticos,  tales  como  monitores  de  televisión  o 
material magnético de almacenamiento de datos.

Do not place loudspeakers in proximity to devices sensitive to 
magnetic  fields  such  as  television  monitors  or  data  storage 
magnetic material.

Este  símbolo  indica  que  el  presente  producto  no  puede  ser 
tratado  como  residuo  doméstico  normal,  sino  que  debe 
entregarse en el correspondiente punto de recogida de equipos 
eléctricos y electrónicos.

This symbol on the product indicates that this product should 
not be treated as household waste. Instead it shall be handed 
over  to  the  appicable  collection  point  for  the  recycling  of 
electrical and electronic equipment.

El  cableado  exterior  conectado  al  equipo  requiere  de  su 
instalación por una persona instruida o el uso de cables flexibles 
ya preparados.

The outer wiring connected to the device requires installation by 
an  instructed  person  or  the  use  of  a  flexible  cable  already 
prepared.

Si  el  aparato  es  conectado  permanentemente,  la  instalación 
eléctrica del edificio debe incorporar un interruptor multipolar con 
separación de contacto de al menos 3mm en cada polo.

If the apparatus is connected permanently, the electrical system 
of  the  building  must  incorporate  a  multipolar  switch  with  a 
separation of contact of at least 3mm in each pole.

No desconecte la tierra en el conector de alimentación pues es 
peligroso  e  ilegal.  Equipo  de  Clase  I.  El  producto  debe  ser 
conectado  a  un  enchufe  con  toma  de  tierra.  Sólo  use  este 
equipo con el cable de red de alimentación adecuado para su 
país.
El  signo  del  rayo  con  la  punta  de  flecha,  alerta  contra  la 
presencia  de  voltajes  peligrosos  no  aislados.  Para  reducir  el 
riesgo de choque eléctrico, no retire la cubierta.

Do not remove mains connector ground, it is dangerous and 
illegal.  Class  I device.  The product  must  be connected  to a 
mains socket outlet with protective earth connection. Only use 
this equipment with an appropriate mains cord for your country.

The lightning and arrowhead symbol warns about the presence 
of uninsulated dangerous voltage. To reduce the risk of electric 
shock, do not remove the cover.

El  signo  de  exclamación  dentro  de  un  triángulo  indica  la 
existencia  de  importantes  instrucciones  de  operación  y 
mantenimiento en la documentación que acompaña al producto.
Conserve y lea todas estas instrucciones. Siga las advertencias.
ATENCIÓN: Es un producto clase A, por lo que en entornos 
domésticos puede causar radio-interferencias, en cuyo caso el 
usuario tendrá que tomar las medidas oportunas.
De acuerdo con EN55103-2, usar el equipo sólo en entornos E1, 
E2, E3 ó E4.

El colgado del equipo sólo debe realizarse utilizando los herrajes 
de  colgado  recomendados  y  por  personal  cualificado.  No 
cuelgue la caja de las asas.

The appliance should be flown only from the rigging points and 
by  qualified  personnel.  Do  not  suspend  the  box  from  the 
handles.

No existen partes ajustables por el usuario en el interior de este 
equipo.  Cualquier  operación  de  mantenimiento  o  reparación 
debe  ser  realizada  por  personal  cualificado.  Es  necesario  el 
servicio técnico cuando el equipo se haya dañado de alguna 
forma, como que haya caído líquido o algún objeto en el interior 
del aparato, haya sido expuesto a lluvia o humedad, no funcione 
correctamente, haya recibido un golpe o su cable de red esté 
dañado.

No user serviceable parts inside. Refer all servicing to qualified 
service personnel. Servicing is required when the apparatus has 
been damaged in any way, such as power-supply cord or plug is 
damaged, liquid has been spilled or objects have fallen into the 
apparatus, the apparatus has been exposed to rain or moisture, 
does not operate normally or has been dropped.

Limpie con un paño seco. No use limpiadores con disolventes.

Clean  only  with  a  dry  cloth.  Do  not  use  any  solvent  based 
cleaners.

Содержание EVENT SERIES

Страница 1: ...zar el equipo lea la sección Precauciones de seguridad de este manual Conserve este manual para futuras consultas Before operating the device please read the Safety precautions section of this manual Retain this manual for future reference line array ...

Страница 2: ...scriptions ON OFF Overload indicator Overheating Equalisation Low mains voltage Current consumption CONFIGURATIONS 4 or 6 units mounting on a PL EV26S flatbed dolly SAFETY PRECAUTIONS WARRANTY DECLARATION OF CONFORMITY Manual del Usuario event series User s Manual Troubleshooting Array mounting of groups of 4 units on a flatbed dolly EVENT 115A array mounting EVENT 26A array mounting one by one EV...

Страница 3: ...e debe entregarse en el correspondiente punto de recogida de equipos eléctricos y electrónicos This symbol on the product indicates that this product should not be treated as household waste Instead it shall be handed over to the appicable collection point for the recycling of electrical and electronic equipment El cableado exterior conectado al equipo requiere de su instalación por una persona in...

Страница 4: ...viamente manipulado e incluir una fotocopia de la factura de compra Todos los detalles relativos a la garantía como las garantías extendidas los puede encontrar en la sección SOPORTE en nuestra web www dasaudio com All our products are warrantied against any manufacturing defect for a period of 24 months from date of purchase The warranty excludes damage from incorrect use of the product All warra...

Страница 5: ...magnetic compatibility of multimedia equipment Emission requirements l EN 55103 2 2009 Electromagnetic compatibility Product family standard for audio video audio visual and entertainment lighting control apparatus for professional use Part 2 Immunity l EN 50581 2012 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substa...

Страница 6: ...installation applications The EVENT 26A combines two 6 5 transducers and a single M 60 compression driver in a rugged yet lightweight polymer cabinet The symmetric V shaped configuration of the cone transducers provides consistent 100º of horizontal coverage down to 200 Hz The M 60 compression driver is coupled to an advanced waveguide design that provides control of the vertical dispersion as wel...

Страница 7: ... for high efficiency and long excursion offering a power handling capacity of 1200 Wprogram Efficient cooling is assured thanks to the 15FW4 s vented pole piece and abundant apertures in the speaker s back plate keeping power compression to a minimum while providing high acoustic output over extended periods Driving the DAS 15FW4 loudspeaker is a cutting edge 1200 Wpeak Class D amplifier On the re...

Страница 8: ...ZT Speaker adaptor for pole mount Dollies PL EV115S Plywood transport dolly for EVENT 115A 1 PL EV26S Steel transport dolly for EVENT 26A 1 Speaker cabling SC2 2m XLR microphone signal balanced cable SC20 20m XLR microphone signal balanced cable 2 2 2 x EVENT 26A 2 x EVENT 115A AXS EV26 TRD 7 AXC ZT MAIN MENU BACK PRESET loud LPF Top MAIN MENU BACK No of U 1U DownFill off ...

Страница 9: ...PL EV115S Plywood transport dolly for EVENT 115A 2 PL EV26S Steel transport dolly for EVENT 26A 2 Speaker cabling SC 1 1m XLR microphone signal balanced cable SC 20 20m XLR microphone signal balanced cable 4 2 PWCONLINK 09 0 9m powerCON jumper NAC3FCB cable 8 SC 05 0 5m XLR microphone signal balanced cable 6 AX EV26 MAIN MENU BACK PRESET loud LPF Top MAIN MENU BACK DownFill off No of U 4U ...

Страница 10: ...dolly for EVENT 115A 2 PL EV26S Steel transport dolly for EVENT 26A 2 Speaker cabling SC 1 1m XLR microphone signal balanced cable SC 5 5m XLR microphone signal balanced cable SC 05 0 5m XLR microphone signal balanced cable 2 2 6 PWCONLINK 09 0 9m powerCON jumper NAC3FCB cable 8 SC 20 20m XLR microphone signal balanced cable 2 AX EV26 PL EV115S MAIN MENU BACK DownFill off No of U 4U MAIN MENU BACK...

Страница 11: ...nal processor 2 10 1 PWCONLINK 09 0 9m powerCON jumper NAC3FCB cable 12 SC 20 20m XLR microphone signal balanced cable 2 AX EV26A MAIN MENU BACK PRESET loud LPF Top MAIN MENU BACK DownFill off No of U 6U www dasaudio com CAUTION DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE RISK OF ELECTRIC SHOCK DO NOT OPEN OUTPUT A OUTPUT B HPF THRU SATELLITE X OVER LIMIT SIGNAL ON POLARITY LEVEL 6 oo 0 LOW P...

Страница 12: ...or 2 10 1 PWCONLINK 09 0 9m powerCON jumper NAC3FCB cable 12 SC 20 20m XLR microphone signal balanced cable 4 12 x EVENT 26A 4 x EVENT 218A MAIN MENU BACK DownFill off No of U 6U www dasaudio com CAUTION DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE RISK OF ELECTRIC SHOCK DO NOT OPEN OUTPUT A OUTPUT B HPF THRU SATELLITE X OVER LIMIT SIGNAL ON POLARITY LEVEL 6 oo 0 LOW PASS 100Hz 63Hz 80Hz INPUT...

Страница 13: ...I 6MI HF 1 x M 60 GM M60N LF 1 x 15FW4 GM 15FW4 Enclosure Geometry Trapezoidal 5º Rectangular Enclosure Material ABS High Impact Birch Plywood Color Finish Black Polyurea Paint Black Polyurea Paint Rigging System Splay Angles Integrated in box design Integrated in box design Connectors INPUT 1 x Female XLR LOOP THRU 1 x Male XLR AC INPUT 1 x powerCON NAC3FCA AC OUTPUT 1 x powerCON NAC3FCB INPUT 2 ...

Страница 14: ...14 Manual del Usuario event series User s Manual LINE DRAWINGS EVENT 115A EVENT 26A ...

Страница 15: ...ckground light of the display can be switched off permanently by selecting in the options Dimming menu the dark preset This option will make the Display blink on and off when the system reaches its limit This option maybe useful in theaters or similar applications in order to reduce the visual contamination 4 ENCODER DAScontrol Use the rotary encoder to navigate for preset selection number of unit...

Страница 16: ...o the Limiter threshold can be monitored on the right meter When the value reaches the limiter threshold the Display will show LIMIT depending on the configuration mode the Display can be programmed to blink when the system is limiting SIGNAL The left meter indicates the presence of signal ON The Display will be illuminated when the system is on The background light of the display can be switched ...

Страница 17: ...m Delay 0 0m OPTIONS OPTIONS MENU OPTIONS MENU BACK BACK CONTRAST 0 BRIGHT 10 BRIGHT 10 CONTRAST 0 OPTIONS MENU OPTIONS MENU OPTIONS MENU MENU LOCK off DLY UNITS m DLY UNITS m DIMMING on DIMMING on DIMMING on MENU LOCK off MENU LOCK off OPTIONS MENU RESET DEVICE INFORMATION Are you sure BACK YES DLY UNITS m off the background light is always on on the background light is lowered when the system doe...

Страница 18: ... DLY UNITS m DLY UNITS m DIMMING on DIMMING on DIMMING on MENU LOCK off MENU LOCK off OPTIONS MENU RESET DEVICE INFORMATION Are you sure BACK YES DLY UNITS m off the background light is always on on the background light is lowered when the system doesn t Limit when Limit is reached the background light increases its luminosity dark the bakcground light is always off RESET DEVICE NO OPTIONS MENU BACK...

Страница 19: ...urs the FAN EVENT 26A will automatically start working reducing the temperature of the unit Make sure that the rain protectors are properly separated from the amplifier s back plate in order to not block the air flux thru the fan Equalisation It is recommended the use of a computer based dual channel FFT platform to view the frequency content of signals or measure the response of the entire electr...

Страница 20: ...ree phase AC the lighting equipment and the UNIT are connected to the same phase 1 Bad or loose AC connection to the UNIT or the mains outlet 2 FaultyAC cable 3 Blown Fuse 4 The mains voltage is out of range SOLUTION 1 Check all the connections and the power distro 2 Check that the cable and connector are working properly 3 Contact with the dealer tech support in the area 1 If you use a mixer be s...

Страница 21: ... elements For slings and elements exposed to material fatigue due to friction and load variation the following ratios must be met 5 1 for steel clable slings 4 1 for steel chain slings and 7 1 for polyester slings Thus an element with a breaking load limit of 1000 kg may be statically loaded with 200 kg 5 1 safety factor and dynamically loaded with 142 kg 7 1 safety factor When a system is flying ...

Страница 22: ...he pin in hole 1º at Rear Link in the first EVENT 26A 4 or 6 units mounting on a PL EV26S flatbed dolly Use 3 pins PIN 6 of the PL EV26S 2 at the front one on each side Rear Link at 1º Fig 1 2 4 6 0 1 3 5 7 9 10 8 10 1 PIN HOLDER Use 4 pins PIN 6 of the bottom EVENT 26A 2 at the front and 2 at the rear link Fig 2 The next figure shows the detail of the label located at the rear rigging structure of...

Страница 23: ...s is shown 4 or 6 units mounting on a PL EV26S flatbed dolly Fig 6 Fig 5 At his point the cover for 4 units could be placed to protect them during transportation Finally the rigging bumper AX EV26 can be attached to the top cabinet using its available pins insert two pins at the front and one at the rear keep the extra pin stored in the cabinet Fig 7 set splay ...

Страница 24: ...3 pins are needed Next step would be running an Ease Focus simulation in order to know the different splay angles between the units and the pick up position pin point of the central bar Before attaching the chain hoist to the AX EV26 the user should be able to vary the splay angles between units and modify them accordingly to the Ease Focus 3 simulation Warning Verify the correct installation of t...

Страница 25: ...it In the sample shown only three pins per cabinet are used set splay angles lower the 4 units Fig 10 Fig 11 NOTE To rig the system the simplest approach is using three pins two at the front and one at the rear With this method the splay angle between units is set automatically while the cabinets are lifted up If the user needs to lock the splay angle between the units an extra pin pin number 4 ha...

Страница 26: ...26 Manual del Usuario event series User s Manual EVENT 115A Array mounting Fig 12 Fig 13 Fig 14 Fig 15 ...

Страница 27: ...27 Manual del Usuario event series User s Manual EVENT 26A Array mounting one by one Fig 16 Fig 17 Fig 18 Fig 19 set splay set splay set splay ...

Страница 28: ...unting Fig 20 JP EV26 First step will be assembling the subwoofers with the AX EV26 follow the process shown on previous pages Next step before hanging the EVENT 26A units is to fix to the bottom EVENT 115A the joining plate JP EV26 Fig 21 Fig 22 Two pins Fig 24 Fig 23 set splay ...

Страница 29: ...ENT 115A Fig 25 Angle between first EVENT 26A and EVENT 115A Cam link Hole real splay angle 9º 4º 8º 4º 7º 2º 6º 2º 5º 0º 4º 0º 3º 2º 2º 2º 1º 3º 0º 3º JP EV26 joining plate is needed to stack the systems Fig 26 Fig 27 set splay angle Fig 28 Fig 29 in this case splay angle 3º ...

Страница 30: ...XS EV26 When using the AXS EV26 to stack the system on a tripod TRD 2 or TRD 7 pole mount and AXC ZT accessoty is also needed Fig 30 AXS EV26 AXC ZT TRD 2 Fig 31 First fix the AXC ZT to the AXS EV26 After first step fix the EVENT 26A to the AXS EV26 Fig 32 Rear View Detail ...

Страница 31: ... 99 event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 208A event 218A event 218A event 218A event 218A event 218A event 218A event 218A event 218A event 121A event 121A event 121A event 121A ...

Страница 32: ...ed by the shield affects both signal conductors in the same way At the device s input the two signals get summed with opposite sign so that noise is cancelled out while the programme signal doubles in level Most professional audio devices use balanced inputs and outputs Connectors that can carry balanced signal have three pins such as XLR Cannon and 6 35mm stereo The graphs that follow show the re...

Страница 33: ...UM_EV3_01_EN www dasaudio com DAS Audio Group S L C Islas Baleares 24 46988 Fuente del Jarro Paterna Valencia España Tel 34 96 134 0860 ...

Отзывы: