Heatsink of EVENT-115A amplifier
Heatsink of EVENT-26A amplifier
Pink Noise
Mains 230 Vrms
1/3 Power
0.8A
1.4A
EVENT-26A
EVENT-115A
19
Manual del Usuario /
event series
/
User’s Manual
Low mains voltage
If mains voltage falls below the shutdown
voltage for the unit, it will stop playing, typically this
value would be below 90Volts. When acceptable
levels are regained, the unit will switch back on
automatically.
Therefore the current consumed by a 115V
version is double the 230V version to achieve the
same acoustic power level.
Air circulates from the bottom to the top of the amplifier.
ON / OFF
A sound system should be switched on
sequentially. Switch on the self-powered units last
in your sound system (switch on the subwoofer
before the mid-high system). Switch on the sound
sources such as CD players or turntables, then the
mixer, then the processors, and finally the self-
powered unit. If you have several units, it is
recommended that you switch them on sequentially
one at a time.
Follow the inverse order when switching off,
turning self-powered units off before any other
element in the sound system.
Disconnect the device by removing the mains
connector from the mains socket. The mains
connector and mains socket must always be freely
accessible and never covered or blocked in any
way.
The models use a power cable equipped with a
Neutrik PowerCon NC3FCA connector. Power can
be daisy chained via the NC3FCB output connector
(see details on product label).
IMPORTANT: Do not disconnect the unit while
in use.
Ensure that the device is disconnected from the
mains by observing that the display is turned off.
Overheating
This equipment does not normally overheat
during normal conditions of use. When overheating
occurs, the FAN (EVENT-26A) will automatically
start working reducing the temperature of the unit.
Make sure that the rain protectors are properly
separated from the amplifier´s back plate in order to
not block the air flux thru the fan.
Equalisation
It is recommended the use of a computer based
dual-channel FFT platform to view the frequency
content of signals or measure the response of the
entire electro-acoustic system, all to better make
informed decisions about the deployment and
operation of these systems.
The unit does not need extreme settings of
equalisation to produce quality sound, just select
the parameter “number of units” in the amplifier that
corresponds to the amount of systems used and
you will achieve a very good and balanced starting
point before measuring and tunning the system.
Avoid high levels of gain on the equalisers. Gain
values above +6 dB on a console’s / processor´s
EQ are not recommended.
Overload indicator (LIMIT / INPUT CLIP)
This device has an indicator (LIMIT / INPUT
CLIP) that it is shown on the display when the signal
level is excessive.
The indicator should not be lit continuously. This
distorts the signal (quickly fatiguing your ears) and
may damage the speakers. Therefore, it is
recommended that you never work with these two
messages engaged; at most it should blink only
occasionally.
RECOMMENDATIONS OF USE
AUDIO MANAGEMENT
PUSH FOR
INPUT
LOOP THRU
Model: EVENT-26A
1
DownFill: off
DELAY: 0.0m
O
No.of U:
1U
INPUT 1
OUTPUT 1
INPUT 2
OUTPUT 2
www.dasaudio.com
AUDIO MANAGEMENT
PUSH FOR DSP
VOLUME
Made in Spain
AC INPUT
115/230 V~ 50/60Hz
325W
T5 A L 250V FUSE
FOR CONTINUED PROTECTION
AGAINST RISK OF FIRE REPLACE
ONLY WITH THE SAME TYPE
Model: EVENT-115A
CAUTION
DO NOT EXPOSE THIS EQUIPMENT
TO RAIN OR MOISTURE
RISK OF ELECTRIC SHOCK
DO NOT OPEN
DAS Audio Group, S.L. (Valencia)
MAX. 10@230V / 4@115V
UNITS EVENT-115A
AC OUTPUT
1 2
loud
Top
0.0m
O
0 dB
3
4
1
2
5
6
7
line array