EN / CZone® Output Interface (MOI) User & Installation Manual
4 DESIGN
•
Ensure load being H-Bridged is capable of being controlled via polarity change.
•
Load must be under 20amps current draw.
•
Make a list of outputs to be wired to the MOI and assign them to one of the 2 output channels.
•
Ensure all cables are appropriately rated for each assigned load.
•
Output connector accepts cable gauges 24AWG – 8AWG (0.5 - 6mm).
•
Ensure power supply cable to the MOI is appropriately rated for the maximum continuous current of all loads
and is fused appropriately to protect the cable.
•
Ensure continuous current draw of each connected load does not exceed maximum channel rating of 20A.
•
Install the appropriately rated fuses for each channel.
•
Loads exceeding 20A will require paralleling 2 channels together.
5 INSTALLATION
THINGS YOU NEED
•
Electrical tools
•
Wiring and fuses
•
Motor Output Interface Module
•
4 x 8G or 10G (4mm or 5mm) self-tapping screws or bolts for mounting the MOI
ENVIRONMENT
Obey the following stipulations during installation:
•
Ensure the MOI is located in an easily accessible location and indicator LED’s are visible.
•
Ensure there is enough clearance above the MOI to allow the cover to be removed.
•
Ensure there is at least 10mm clearance around the sides and top of the MOI.
•
Ensure the MOI is mounted on a vertical flat surface.
•
Ensure there is sufficient space for the wires to exit the product.