11
EN / CZone® Output Interface (MOI) User & Installation Manual
CONNECTIONS
The MOI has a convenient output connector that requires no crimping tools and accepts cables from 24AWG to 8AWG
(0.5 - 6mm). The unit has no power key and will turn on when power is applied to the network. The module will continue
to draw power even when it is not in operation. It is recommended that a battery isolator switch is installed for when the
system is not in use.
1. Feed output wires through cable grommet
2. Strip and insert each wire into the connector ensuring the correctly rated wire is used for each load and tighten
screws to 4.43 in/lbs (0.5NM).
3. Insert plug firmly into module and tighten 2x retaining screws.
4. Connect a NMEA2000 drop cable from the NMEA2000 backbone (do not power up network yet).
IMPORTANT
- The positive cable must be sufficient size to carry the maximum current of all loads connected
to the MOI. It is recommended to have a fuse/circuit breaker rated to protect the cable.
1
4
3
2
MOI Connections
DC Negative Input
DC Positive Input
Reversible output pair
Positive DC Output 1
Positive DC Output 2