6  ORDERING INFORMATION 

Part Numbers and Accessories 

Part Number 

Description 

80-911-0007-00

 

CZONE MOI C/W CONNECTORS

 

80-911-0008-00 

CZONE MOI NO CONNECTORS 

80-911-0041-00 

TERM BLOCK OI 6W PLUG 10 16 PITCH 

80-911-0034-00 

SEAL BOOT for CZONE OI 6W CONN BK SILICON 

 
 

7  SPECIFICATIONS 

  TECHNICAL SPECIFICATIONS 

Technical Specification 
Circuit protection

 

ATC Fuse with Blown Fuse Alarms 

NMEA2000 connectivity

 

1 x CAN Micro-C port 

Output wire range

 

0.5 - 6mm (24AWG – 8AWG)

 

Output channels

 

1x 20A H-Bridge channel 12/24, 2 x 20A Output channels 12/24V

 

Maximum current

 

60A Total Module Current

 

Dimming

 

Output channels, PWM @100Hz 

Power supply

 

M6 (1/4") Positive Terminal (9-32V) 

Network Supply voltage

 

9-16V via NMEA2000

 

Circuit bypass

 

Mechanical Fuse Bypass on all Channels

 

Ingress protection

 

IPx5 (mounted vertical on bulkhead and flat)

 

Compliance

 

CE, ABYC, NMEA, ISO8846/SAEJ1171 Ignition Protected 

Power consumption max

 

85mA @12V

 

Power consumption standby

 

60mA @12V 

Warranty period

 

2 years 

Operating temperature range

 

-15C to +55C (-5F to +131F) 

Storage temperature range

 

-40C to +85C (-40F to +185F) 

Dimensions W x H x D

 

202.5 x 128.5 x 45mm (7.97 x 5.06 x 1.77”) 

Weight

 

609g  

 

 

 

 

Содержание 80-911-0007-00

Страница 1: ...Motor Output Interface MOI User Installation Manual V2 0...

Страница 2: ...cations of either its products or associated documentation Translations In the event that there is a difference between a translation of this manual and the English version the English version should...

Страница 3: ...nance And Repair 5 General Safety and Installation Precautions 5 3 OVERVIEW 6 Description 6 Features 6 MOI Hardware Overview 7 Led indicators 8 4 DESIGN 9 5 INSTALLATION 9 Things You Need 9 Environmen...

Страница 4: ...s chapter 2 of this manual Please keep this manual in a secure place GUARANTEE SPECIFICATIONS BEP Marine guarantees that this unit has been built according to the legally applicable standards and spec...

Страница 5: ...the MOI in locations where there is danger of gas or dust explosion or potentially flammable products 3 Use of the MOI other than mentioned in point 2 is not considered to be consistent with the inten...

Страница 6: ...cables of up to 16 mm2 6AWG in size or multiple smaller conductors No need for specialized crimp terminals and expensive crimp tools to be carried for terminations to CZone just a blade screwdriver A...

Страница 7: ...tput Circuit Fuses 12 Dipswitch 13 NMEA 2000 Connector 1 DC Power LED 2 Waterproof Cover 3 Circuit ID Labels 4 Protective Boot 5 Channel Status LEDs 6 Network Status LED 7 Module ID Label MOI HARDWARE...

Страница 8: ...dule Not Configured 2 Red Flash Configuration Conflict 3 Red Flash DIP Switch Conflict 4 Red Flash Memory Failure 5 Red Flash No Modules Detected 6 Red Flash Low Run Current 7 Red Flash Over Current 8...

Страница 9: ...f each connected load does not exceed maximum channel rating of 20A Install the appropriately rated fuses for each channel Loads exceeding 20A will require paralleling 2 channels together 5 INSTALLATI...

Страница 10: ...cable grommet for wiring bend radius o Note Cable radius determined by wiring manufacturer 3 Fasten the MOI by using 4 x 8G or 10G 4mm or 5mm self tapping screws or bolts not supplied IMPORTANT The M...

Страница 11: ...utput wires through cable grommet 2 Strip and insert each wire into the connector ensuring the correctly rated wire is used for each load and tighten screws to 4 43 in lbs 0 5NM 3 Insert plug firmly i...

Страница 12: ...MAL bottom position of all circuits 3 The ATC fuse should be rated to protect the connected load and the wiring from the MOI to the load and also the ground wire MECHANICAL BYPASS The MOI includes a m...

Страница 13: ...ve advanced functionality such as timers load shedding or one touch Modes of operation a custom configuration needs to be installed Set the dipswitch on the MOI to match the configuration file All oth...

Страница 14: ...e purchased a label sheet WARNING The MOI is only ignition protected with the cover correctly installed INITIAL POWER UP 1 Power up the NMEA2000 Network system will flash all outputs for a short time...

Страница 15: ...SYSTEM DIAGRAM EXAMPLES System Diagram BILGE PUMP BATTERY HATCH LIFTER NMEA 2000 NETWORK DC Negative Input DC Positive Input Reversible output pair CIRCUIT BREAKER Positive DC Output 1 Positive DC Out...

Страница 16: ...0 5 6mm 24AWG 8AWG Output channels 1x 20A H Bridge channel 12 24 2 x 20A Output channels 12 24V Maximum current 60A Total Module Current Dimming Output channels PWM 100Hz Power supply M6 1 4 Positive...

Страница 17: ...ssenger cars and light commercial vehicles with nominal 12 V supply voltage Electrical transient conduction along supply lines only ISO 7637 2 24V Commercial vehicles with nominal 24 V supply voltage...

Страница 18: ...EN CZone Output Interface MOI User Installation Manual 18 8 Declaration of Conformity...

Отзывы: